Login:
Sorted: Name ↑   Downloads   Rate   Size ↑  

These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors. IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moistur

Desa Tech Vent-Free Gas and Electric Hearth

downloaded: 0File size: 3 mb    Manafacture: Desa Tech  
Category: Fireplaces

With zone heating, you save 3% on your energy bill for every 1°-thermostat set-back. That’s 15% for every 5°! Your savings can total $312* annually. * Cost savings based on a 5° thermostat set-back. Calculations established on average natural gas/propane heating costs published by U.S. Department of Energy. Gas is still a better value than wood or electricity! $0.37$0.61$0.83$0.94Ideal for any season, new LED flame. Approved for use in any room of the home. Easy operation -Great value --Unparall

Desa Tech SPACE-RAY Infrared Gas Tube Heaters

downloaded: 0File size: 2 mb    Manafacture: Desa Tech  
Category: Gas Heaters

combustion air intake and vent ■ Direct spark ignition system with step opening gas valve and 100% Gas Shut-Off Safety Control (pre-purge) ■ Monitoring lights for visual diagnosis of maintenance needs OTHER ■ Lower mounting height kit required on heater installations between 6 and 8 feet ■ Optional deflector kit for reduced clearances to combustible materials ■ Optional decorative grille kit for drop ceiling applications TECHNICAL SPECIFICATIONS CB20 20,000 CB40 40,000 CB30 30,000

Desa Tech SL30PT

downloaded: 2File size: 590 kb    Manafacture: Desa Tech  
Category: Gas Heaters

Gas leak. See Warning statement at 1. Locate and correct all leaks (see Check- position top of page ing Gas Connections, page 12) 2. Control valve defective 2. Replace control valve Gas odor during combustion 1. Foreign matter between control valve 1. Take apart gas tubing and remove for- and burner eign matter 2. Gas leak. See Warning statement at 2. Locate and correct all leaks (see Check- top of page ing Gas Connections, page 12) 18 OWNER’S MANUAL These Parts Centrals are privately owned busi

Desa Tech SL30NT

downloaded: 0File size: 458 kb    Manafacture: Desa Tech  
Category: Electric Heaters

These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors. IMPORTANT:Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture

Desa Tech S39NT

downloaded: 9File size: 806 kb    Manafacture: Desa Tech  
Category: Kitchen-ranges

When ordering parts, follow the instructions PARTS LIST listed under Replacement Parts on page 24 of this manual. S39NT KEY NO. PART NO. DESCRIPTION QTY. 1 107085-01CK Top Panel, Stove 1 2 107077-01CK Pedestal Stove Assembly 1 3 107076-01CK Stove Base 1 4 107075-01CK Stove Back Panel 1 5 107082-01CK Top Trim 1 6 105657-01 Blower Bracket 2 7 107363-01CK Door 1 8 107078-01CJ Firebox Back Panel 1 9 107080-01CK Firebox Floor 1 10 107081-01CJ Firebox Top 1 11 107365-01CK Screen Assembly 1 12 101382-0

Desa Tech S26PTA

downloaded: 7File size: 691 kb    Manafacture: Desa Tech  
Category: Fireplaces

7. Attach the two mounting brackets to blower housing using four screws provided in blower kit (2 for each bracket) (see Figure 16, page 13). Tighten screws securely. Place blower assembly temporarily on top of firebox. 8. Working from the rear of the stove, place entire power cord, including speed control housing, in lower control compartment. 9. Route ends of 3-wire power cord up from the lower control compartment through the plastic bushing, then up to the upper cavity of stove (see Figure 17

Desa Tech S26PT

downloaded: 0File size: 185 kb    Manafacture: Desa Tech  
Category: Cooktops

Desa Tech S26PT

downloaded: 0File size: 956 kb    Manafacture: Desa Tech  
Category: Cooktops

Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a qualified installer, service agency, or the gas supplier. WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or

Desa Tech S26NTA

downloaded: 8File size: 691 kb    Manafacture: Desa Tech  
Category: Fireplaces

Burner orifice clogged 2. Inlet gas pressure is too low 3. Thermopile leads disconnected or improperly connected 4. Burners will not come on in remote position 1. Clean burner (see Cleaning and Maintenance, pages 16 and 17) or replace burner orifice 2. Contact local gas company 3. Reconnect leads (see wiring diagram) 4. Replace battery in transmitter and receiver Delayed ignition burner 1. Manifold pressure is too low 2. Burner orifice clogged 1. Contact local gas company 2. Clean burner (see Cl





Category