It will be necessary to cut wall studs and install a header and sill frame to maintain proper dimensions and to hold the weight of the brick (Figure 11). 10 INSTALLATION USING MASONRY OR BRICK CHIMNEY Minimum 3 %" (89mm) [4" (102mm) nominal] thick solid bricks are to be used. The fire clay liner (ASTM C35 or equivalent), 5/8" (16mm) wall thickness, must not penetrate into the chimney beyond the inner surface of the chimney flue liner and must be firmly cemented in place. If it is necessary to
Do not remove ground prong from plug. Route power cord to avoid heat from the stove, or other damage. 3. Adjust the blower speed control to the desired speed. BLOWER SWITCH ADJUSTMENTS The blower speed control for this unit is adjusted at the factory, and should not require further adjustment. When the speed control is turned clockwise, it will click on to high speed. Turn the speed control clockwise to decrease the speed. At full clockwise, the blower should blow gently, but should not stop.
Printed in U.S.A. Copyright 2000, Heat-N-Glo, a division of Hearth Technologies Inc. 20802 Kensington Blvd., Lakeville, MN 55044 Models: WS-150 WS-250 1. When installing your stove, particular attention should be paid to fire protection. If this unit is not properly installed, a house fire may result. For your safety, follow the installation instructions and contact local building or fire officials about restrictions and installation inspection requirements in your area. 2. Never use gasoline or
If the defect is reported during the first year from the date of installation (stainless steel burners and fi ber logs are covered for 3 years), HEAT & GLO will replace or repair the defective components at its sole expense. The decision whether to replace a component shall be made at HEAT & GLO’s sole discretion. This Limited Warranty does not cover components broken during shipping, misuse or careless handling. HEAT & GLO shall not be responsible for any indirect, incidental, or consequential
AUSTRALIAN GAS ASSOCIATION CERTIFIED Certifi cate Number: 7153 Model: VRTIKL-AU FREESTANDING STOVE • Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - Do not try to light any appliance. - Do not touch any electrical switch. Do not use any phone in your building. - Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. - If you cannot reach your gas suppli
Do NOT use gasoline, lantern fuel, kerosene, charcoal lighter fluid or similar liquids in this appliance. Combustible materials may ignite. E. Frequently Asked Questions ISSUE SOLUTIONS Condensation on the glass This is a result of gas combustion and temperature variations. As the appliance warms, this condensation will disappear. Blue flames This is a result of normal operation and the flames will begin to yellow as the appliance is allowed to burn for 20 to 40 minutes. Odor from appliance When
Fuel Conversions Before making gas connections ensure that the appliance being installed is compatible with the available gas type. Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a qualified technician using Hearth & Home Technologies specifi ed and approved parts. 1. Converting to LP Gas Figure 6.2the wire clip. Pull off pilot hood and set aside. Do not remove MILLIVOT GENERATOR THERMOCOUPLE PILOT HOOD ALIGNMENT NOTCH NOTE: Gas conversi
Vent system termination is permitted in porch areas with two or more sides open. You must follow side wall, overhang and ground clearances as stated in the instructions. Quadra-Fire assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements. NOTE 3: Location of the vent termination must not interfere with access CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, Figure 4.4 IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE
Optional High Wind Termination Cap Secure Flashing with Non-Hardening Sealant and Roofing Nails Figure 5.15 Step 9. Twist-lock the vent cap and seal. Note: For multi-story vertical installations, a ceiling firestop is required at the second floor, and any subsequent floors (Figure 5.16). The opening should be framed to 10 in. x 10 in. (254mm x 254mm) inside dimensions, in the same manner as shown in Figure 5.13 on page 16. MIN. 1 in. (25mm) CLEARANCE CEILING FIRES TOP NAILS MIN. 1 in. (25mm) CLE