Remove rear grille 3. Loosen both hose clamps on condenser hoses. Remove hose from condenser outlet (top) 4. With cup/pail at the ready, remove hose from condenser inlet (bottom). Drain condenser and hose 5. Loosen both hose clamps on water regulating valve. Using utility knife, cut both hose ends to facilitate hose removal from barbed fittings on valve 6. Remove both hoses and discard 7. Remove 2 screws from gray plastic drain manifold (some machines have brass winged adapter) on back pane

Manitowoc Ice Q-SERIES Q-0600

downloaded: 4File size: 181 kb    Manafacture: Manitowoc Ice  
Category: Water and Air Pumps

NO CHANGES WITH START/RUN COMPONENTS ARE NEEDED. 1. Disconnect power to the ice machine at the electrical 8. Remove extra section of suction service valve disconnect (moving the toggle switch to the off process tube from the ice machine at swedge joint. position will not disconnect line voltage). Repeat this procedure with discharge line. Remove 2. Remove panels (top, front, left and right sides). up to T section. 3. Recover refrigerant from ice machine. 5. Remove wiring from compressor term

Manitowoc Ice Q-1809

downloaded: 0File size: 16 kb    Manafacture: Manitowoc Ice  
Category: Water Systems

Manitowoc Ice Q-0420

downloaded: 10File size: 120 kb    Manafacture: Manitowoc Ice  
Category: Water and Air Pumps

4. Pull evaporator away from bulkhead. Place bottom of mylar strip in sump trough and slip up behind evaporator (align slot cut in step 3 with bin switch wire). Mylar must extend above bottom evaporator mounting screw (approximately 2” above gasket/bulkhead joint). 5. Remove paper backing from mylar. Apply tension to mylar to eliminate wrinkles. 6. Align evaporator extrusion and bulkhead screw holes; puncture mylar for the bottom screw holes and insert screws. Install all remaining evaporator sc

Manitowoc Ice Q-0320

downloaded: 6File size: 120 kb    Manafacture: Manitowoc Ice  
Category: Water and Air Pumps

Preparation 1. Disconnect power from ice machine. 2. Remove front, top, and side panels. 3. Drain water from sump trough. 4. Ice machine must be thoroughly dried before the insulation can be installed. Use towels to dry bulkhead and base assembly. Base Insulation Installation 1. Raise the ice machine above the bin. A high lift can be used, or (two people required) lift front edge of ice machine and place wood blocks (2”x 4”) between ice machine and bin. Lifting one side of ice machine at a time,

Manitowoc Ice MFD-51

downloaded: 4File size: 58 kb    Manafacture: Manitowoc Ice  
Category: Water Dispensers

Box 1720, Manitowoc, WI 54221-1720 USA Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879 Web Site - 8003813 Rev. 10/16/03

Manitowoc Ice K00334

downloaded: 0File size: 26 kb    Manafacture: Manitowoc Ice  
Category: Baby Furniture

The thumbscrews should be used to lock the shelf pilasters in place at the top of the cabinet. 4. (Use steps 4 and 5, when installing on top half.) Install your precut wire shelf pilasters to the bottom half of the cabinet first. 5. Install your tray slide pilasters using the bottom slotted holes on the pilaster, as shown in Fig. 4. Press in and down to lock into place. Use the thumbscrews to lock into place. 6. When installing a full cabinet door of tray slides, always start with the bottom

Manitowoc Ice K00333

downloaded: 0File size: 26 kb    Manafacture: Manitowoc Ice  
Category: Baby Furniture

t Q Part No. Description 1 4 3203343 Wire Shelf Pilaster 2 16 6022201 Tray Slide 3 1 6022191 Tray Slide Pilaster - 2 Dr. 4 3 6022301 Tray Slide Pilaster 5 47” 9202503 Tape, Extruded READ INSTRUCTIONS COMPLETELY BEFORE INSTALLATION 1. Remove all wire shelves from door opening. Remove existing pilasters by removing the thumbscrews at the top and lifting up and off the mounting studs. 2. (Use steps 2 and 3, when installing on bottom half.) Use top slotted holes on tray slide pilaster, as sh

Manitowoc Ice J-1300

downloaded: 7File size: 12 kb    Manafacture: Manitowoc Ice  
Category: Water and Air Pumps

For ease of installation, position compressor on mounting bolt so that the suction port is to the rear of the ice machine. Note: Reducer bushings are provided for suction and process ports. Manitowoc Ice, Inc. 2110 South 26th Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879 8011053 Web Site - Rev. 06/19/03

Manitowoc Ice J-0600

downloaded: 13File size: 121 kb    Manafacture: Manitowoc Ice  
Category: Water and Air Pumps

Deburr suction line before fitting new tubing in. 11. Braze all tubing into place. Purge system with nitrogen during all brazing operations on the ice machine. NOTE: IF REPLACING COMPRESSOR INTO A REMOTE ICE MACHINE, MAKE SURE TO FIRST FOLLOW INSTRUCTIONS A, B, AND C BELOW, BEFORE PROCEEDING TO INSTRUCTION #10. A. Replace elbow with “T” fitting. 12. Use electrical tape to seal suction line insulation. B. Replace HPR valve and L-shaped tube that was removed earlier. Adjust to fit without ru