Burner will not come on. Control knob frozen – will not turn. Carbon or sooting on logs. POSSIBLE CAUSE Altitude is above 4000 ft.; ODS sensor requirement for air not satisfied.> Defective thermopile.> Pilot orifice may be clogged.> Defective valve magnet.> Control knob not fully pressed in.> Control knob not pressed in long enough.> Manual shut-off valve not fully open.> Low gas pressure.> Dirty or clogged “ODS” pilot.> Thermopile damaged.> Control valve damaged.> Burner orifice clogged.> Orifi
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. UNVENTED ROOM HEATER MODELS: 26-GULP 26-GUNG 60-SHULP 60-SHUNG 60-TRULP 60-TRUNG 26-GUHLP 26-GUHNG 60-SHUHLP 60-SHUHNG 60-TRUHLP 60-TRUHNG INSTALLATION AND OPERATING INSTRUCTIONS England’s Stove Works highly recommends the use of smoke detectors and Carbon Monoxide detectors with any hearth product, including this unit. Follow all manufacturer’s instructions when using smoke or Carbon Monoxide det
TO TURN GAS OFF TO APPLIANCE 1) Set thermostat to the lowest setting. 2) Turn off all electric power to the appliance if service is to be performed. 3) Remove control access panel. 4) Turn knob “A” clockwise > until it stops. 3) 4) Set thermostat to desired setting. To turn off the gas to the main burner only, turn gas control clockwise > to pilot. 5) 6) Press down slightly and continue turning clockwise > from pilot position to “OFF”. Replace control access panel. MAINTENANCE INSTRUCTIONS 1) Pe
INPUT 34,500 BTU/HR 30,000 BTU/HR MIN. INPUT 20,000 BTU/HR 20,000 BTU/HR MANIFOLD PRESSURE 3.5” W.C. 10” W.C. M/FOLD PRESSURE LOW 1.0/3.5” W.C. 4.5/10.0” W.C. MIN. INLET PRESSURE 5.0” W.C. 11.0” W.C. MIN. SUPPLY PRESSURE 5.5” W.C. 11” W.C. MAX. SUPPLY PRESSURE 10.5” W.C. 14” W.C. ORIFICE SIZE #34 #51 MINIMUM CLEARANCES TO COMBUSTIBLES England’s Stove Works highly recommends the use of smoke detectors and Carbon Monoxide detectors with any hearth product, including this unit. Follow all manufactu
*Note: Parts orders ONLY: call (800) 516-3636. Technical problems: call (800) 245-6489. TROUBLE SHOOTING GUIDE ITEMS IN THIS GUIDE MARKED WITH AN ASTERISK (*) SHOULD ONLY BE PERFORMED BY A LICENSED GAS FITTER OR EQUIVALENT. WARNING CAUTION Turn off and let the unit cool before servicing. Never use a wire, needle, or similar Only a qualified service person should object to clean the ODS pilot. service or repair this unit. This can damage the pilot. PROBLEM When ignitor is pressed there is no ODS
CONSUMER: Retain this manual for future reference. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. UNVENTED ROOM HEATER MODELS: 26-GULP 26-GUNG 60-SHULP 60-SHUNG 60-TRULP 60-TRUNG 26-GUHLP 26-GUHNG 60-SHUHLP 60-SHUHNG 60-TRUHLP 60-TRUHNG INSTALLATION AND OPERATING INSTRUCTIONS England’s Stove Works highly recommends the use of smoke detectors and Carbon Monoxide detectors with any hearth product, including this unit. Follow all manufacturer’s i
TO TURN GAS OFF TO APPLIANCE 1) Set thermostat to the lowest setting. 2) Turn off all electric power to the appliance if service is to be performed. 3) Remove control access panel. 4) Turn knob “A” clockwise > until it stops. 3) 4) Set thermostat to desired setting. To turn off the gas to the main burner only, turn gas control clockwise > to pilot. 5) 6) Press down slightly and continue turning clockwise > from pilot position to “OFF”. Replace control access panel. MAINTENANCE INSTRUCTIONS 1) Pe
We are nearly always able to help “walk you through” any repairs, problems or questions you may have. PLEASE NOTE: While information obtained on our web site and through our 800 number is always free of charge, there will be a service charge incurred with any “on-site” repairs or maintenance that we may arrange. Wishing you years of efficient, quality and “comfy” heating, England’s Stove Works Technical Support Department (800) 245-6489 IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO TH
PO Box 206 Monroe, VA 24574 REV. 9/5/2012 CAUTION Please read this entire manual before installation and use of this pellet fuel. burning appliance. Keep children, furniture, fixtures and all combustibles away from any heating appliance. SAFETY NOTICE Failure to follow these instructions can result in property damage, bodily injury or even death. For your safety and protection, follow the installation instructions outlined in this manual. Contact your local building or fire officials about restr
. A specially designed ash vacuum and pellet stove cleaning kit is available from the England’s Stove Works website; please see: . Once all ash has been removed from the exhaust chamber, reinstall the cleanout port covers, using the screws previously removed. . Be certain to tighten the screws down to sufficiently seal the cleanout port covers, but do not over.tighten them, as it possible to damage the screw. Venting Pipe Cleaning . Low spots and direction changes in the venting system (such as