. . . . . 2 SYSTEM OPERATION . . . . . . . 2 SETTING THE THERMOSTAT . . . . 2 COOLING CYCLE . . . . . . . . . . . . . . 3 TO MAXIMIZE OPERATING EFFICIENCY . . . . . . . . . . . . . . . 3 HEATING CONSERVATION . . . . . . 3 COOLING CONSERVATION . . . . . . 3 CARE OF SYSTEM . . . . . . . . . . 3 COIL CARE . . . . . . . . . . . . . . . . . . .3 CARE OFFAN MOTORS . . . . . . . . . 4 FILTER CARE . . . . . . . . . . . . . . . . .4 OUTDOOR UNIT FINISH . . . . . . . . . 4 CLEARANCES . . . . . . . . . . .
For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. CAB All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. DIMENSIONS Unit Model Dimensions (Inches) Refrigerant Connection Service Valve Size A1 B C Liquid Vapor 036 25 35 23 3/4” 048 33 37 27 3/8” 7/8” 060 26 43 32 7/8” 1. Including fan guard. Unitary Products Group 279104-YTG-B-0
KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor. EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 1. TXV
TXV = Use 1TV700 Series Kit. * Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. Unitary Products Group 279104-YTG-B-0307 HEATING PERFORMANCE - With Air Handler UNIT MODEL* COIL1 MODEL ARI HEATING2 OUTDOOR TEMP3 47°F 17°F HSPF -3°F 7°F 17°F 27°F 37°F 47°F 57°F MBH COP MBH COP STD MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW E1RA036S(25,4 F2RP/F2FP036 34.0 3.00 20.4 2.16 7.2 15.5 2.40 15.6 2.54 20.
SOUND POWER RATINGS* UNIT MODEL (dBA) 018 80 024 80 030 80 036 82 042 82 048 77 060 82 * Rated in accordance with ARI 270-95 Standards. MINIMUM24”SERVICEACCESSCLEARANCEONONESIDE60”OVERHEADCLEARANCE10”CLEARANCECOILAREAWEATHERPROOFDISCONNECTSWITCHTHERMOSTATTOFURNACEORAIRHANDLERTERMINALBLOCKNECCLASS1WIRINGNECCLASS2WIRINGTOINDOORCOILSEALOPENING(S)WITHPERMAGUMOREQUIVALENTCONTROLACCESSPANELNOTE:ALLOUTDOORWIRINGMUSTBEWEATHERPROOF. Unitary Products Group 279104-YTG-B-0307 TYPICAL FIELD WIRING - 3 PH (03
Visit us on the web at DESCRIPTION The HRA Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be custom matched with one of UPG’s complete line of evaporator sections, each designed to serve a specific function. Matching Air Handlers are available for upflow, downflow or horizontal applications to provide a complete system. Electric Heaters are available if required. Add-On coils are available for use with upflow, downflow or horizontal furnac
. . . . . . . . . . . . . 2 Y2K COMPLIANCE. . . . . . . . . . . . . . . . 2 THERMOSTATS . . . . . . . . . . . . . . . . . . . 2 COOLING AND HEATING . . . . . . . . . . 2 FAN OPERATION. . . . . . . . . . . . . . . . . 2 START-UP. . . . . . . . . . . . . . . . . . . . . . . . 3 POWER FAILURE. . . . . . . . . . . . . . . . . 3 SYSTEM OPERATION . . . . . . . . . . . . . . 3 MANUAL CHANGE-OVER THERMOSTAT . . . . . . . . . . . . . . . . . . . 3 ELECTRONIC THERMOSTAT . . . . . . . 3 CARE OF SYSTEM. . .
models. All ratings remain the same. 5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard. - = Not applicable. 6 Unitary Products Group 036-21137-004 Rev. C (0505) COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (Min.-max.) W RATED CFM NET MBH SEER W/O TXV SEER + TXV1 EER TOTAL SENS. 14,17 G1FA024S14,17 600 19.2 13.0 12.00* 12.00 11.35 14 G1HA024H14 60
TXV = Use 1TV700 Series Kit. ‘Requires 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. Unitary Products Group 9 036-21137-004 Rev. C (0505) COOLING CAPACITY - With Variable Speed Furnaces VARIABLE SPEED FURNACE MODEL COOLING UNIT MODEL COIL MODEL1 W RATED NET MBH SEER SEER EER CFM TOTAL SENS. W/O TXV + TXV2 1 PH 12 SEER AC - VARIABLE SPEED3 P1DUA12V/PV8A12****UH G1FA024S14 14
SYSTEM OPERATION Your thermostat puts full control of the comfort level in your home at your fingertips. DO NOT switch your thermostat rapidly “On” and “Off” or between “Heat” to “Cool” This could damage your equipment. Always allow at least 5 minutes between changes. SETTING THE THERMOSTAT Although thermostats may vary widely in appearance, they are all designed to perform the same basic function: to control the operation of your air conditioning or heat pump system. Regardless of size or shape