Login:
Votes - 1, Average rating: 4 ( )

User manual York, model 090

Manafacture: York
File size: 231.72 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


SOUND POWER RATINGS* UNIT MODEL (dBA) 018 80 024 80 030 80 036 82 042 82 048 77 060 82 * Rated in accordance with ARI 270-95 Standards. MINIMUM24”SERVICEACCESSCLEARANCEONONESIDE60”OVERHEADCLEARANCE10”CLEARANCECOILAREAWEATHERPROOFDISCONNECTSWITCHTHERMOSTATTOFURNACEORAIRHANDLERTERMINALBLOCKNECCLASS1WIRINGNECCLASS2WIRINGTOINDOORCOILSEALOPENING(S)WITHPERMAGUMOREQUIVALENTCONTROLACCESSPANELNOTE:ALLOUTDOORWIRINGMUSTBEWEATHERPROOF. Unitary Products Group 279104-YTG-B-0307 TYPICAL FIELD WIRING - 3 PH (036 - 060) THERMOSTATINDOORUNITOUTDOORUNITLOWVOLTAGETERMINALBLOCKINAIRHANDLERWITHELECTRICHEAT3,4DEFROSTCONTROL1FIELDINSTALLEDJUMPERGND. SCREWCONTACTORT2T1L2L1MRLorXYOWGT2E2RRYYOOW2WW1CXGW1GND. LUGPOWERWIRING24VCONTROLWIRING(NECCLASS2) JUMPERTERMINALSEANDWTOHEATONFIRSTSTAGEDURINGEMERGENCYHEAT. 12TERMINALNOTUSEDONALLTHERMOSTATS. POWERWIRING208/230-3-60460-3-503CHECKTHELOWVOLTAGETERMINALBLOCKONTHEINDOORUNITFORTHEACTUALARRANGEMENTOFTHETERMINALS. 4CONNECTPOWERWIRINGTOTERMINALBLOCK3TBONUNITSWITHOUTELECTRICHEATORCIRCUITBREAKER. BorCALLFIELDWIRINGTOBEINACCORDANCEWITHELECTRICCODE(NEC)AND/ORLOCALCODESREDBLKYELORGBRNPURWHT/665GRAYFORUSEWITHOPTIONALOUTDOORTHERMOSTATKITS. BorCPOWERSUPPLY208/230-3-60460-3-50T3L3CCGRY5 TYPICAL FIELD WIRING - 3 PH (090) THERMOSTATINDOORUNITOUTDOORUNITLOWVOLTAGETERMINALBLOCKINAIRHANDLERWITHELECTRICHEAT3,4DEFROSTCONTROL1FIELDINSTALLEDJUMPERGND. SCREWCONTACTORT2T1L2L1MRXYOWGT2E2RRYYOOWWW1CX53GGND. LUGPOWERWIRING24VCONTROLWIRING(NECCLASS2) JUMPERTERMINALSEANDWTOHEATONFIRSTSTAGEDURINGEMERGENCYHEAT. 12TERMINALNOTUSEDONALLTHERMOSTATS. POWERWIRING208/230-3-60460-3-503CHECKTHELOWVOLTAGETERMINALBLOCKONTHEINDOORUNITFORTHEACTUALARRANGEMENTOFTHETERMINALS. 4CONNECTPOWERWIRINGTOTERMINALBLOCK3TBONUNITSWITHOUTELECTRICHEATORCIRCUITBREAKER. BorCALLFIELDWIRINGTOBEINACCORDANCEWITHELECTRICCODE(NEC)AND/ORLOCALCODESREDBLKYELORGBRNPURWHT/66CPOWERSUPPLY208/230-3-60460-3-50T3L3X60605FIELDINSTALLEDJUMPER3TERMINALNOTUSEDONALLTHERMOSTATS. 5REQUIREDONALLELECTRICHEAT Unitary Products Group 279104-YTG-B-0307 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. E1RA036S(25,46) INDOOR COIL MODEL NO. F2RP/F2FP036 CONDENSER ENTERING AIR TEMPERATURE ID CFM 1000 1250 1400 ID DB (°F) 85 80 75 70 85 80 75 70 85 80 75 70 ID WB (°F) 72 67 62 57 72 67 62 57 72 67 62 57 75 T.C. 38.1 35.0 32.5 29.4 38.6 35.5 32.9 29.9 38.8 35.7 33.2 30.2 S.C. 22.9 22.9 22.1 23.6 24.1 24.2 23.4 24.8 24.9 24.9 24.1 25.5 KW 3.15 3.08 3.02 2.94 3.16 3.10 3.03 2.96 3.17 3.10 3.04 2.97 85 T.C. 37.6 34.6 32.0 28.9 38.1 35.1 32.7 29.4 38.3 35.3 33.0 29.7 S.C. 23.3 23.4 22.6 23.9 24.8 24.9 24.1 25.3 25.7 25.7 25.0 26.1 KW 3.39 3.30 3.22 3.12 3.40 3.32 3.24 3.14 3.41 3.33 3.25 3.15 95 T.C. 36.2 33.3 30.9 27.7 36.7 33.7 31.4 28.3 36.8 34.0 31.6 28.6 S.C. 23.3 23.3 22.6 23.7 24.9 24.9 24.0 25.4 25.8 25.9 24.9 26.2 KW 3.71 3.60 3.51 3.38 3.72 3.62 3.53 3.40 3.74 3.64 3.55 3.42 105 T.C. 34.4 31.5 29.2 26.3 34.7 32.0 29.6 26.8 35.0 32.2 29.9 27.3 S.C. 22.9 22.9 22.1 23.3 24.5 24.5 23.5 24.7 25.6 25.5 24.6 25.5 KW 4.03 3.90 3.79 3.63 4.06 3.93 3.82 3.67 4.06 3.94 3.82 3.71 115 T.C. 32.2 29.6 27.4 24.7 32.6 30.0 27.8 25.5 32.8 30.2 28.1 25.8 S.C. 22.2 22.2 21.4 22.4 23.9 23.8 22.9 23.8 24.8 24.8 23.8 24.1 KW 4.34 4.19 4.05 3.88 4.37 4.22 4.09 3.93 4.38 4.24 4.10 3.96 125 T.C. 30.0 27.7 25.6 23.1 30.5 28.0 26.0 24.2 30.6 28.2 26.3 24.3 S.C. 21.5 21.5 20.6 21.5 23.3 23.1 22.2 22.9 24.0 24.1 23.1 22.7 KW 4.65 4.48 4.31 4.13 4.68 4.51 4.36 4.19 4.70 4.54 4.38 4.21 NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW MA12BN2,4 FC/MC35B3X 1.01 1.02 1.01 MA12BN2,4 FC/MC36B3X 1.01 1.02 1.01 MA12BN2,4 FC/MC42B3X 1.01 1.02 1.01 MA12BN2,4 G2FD042(S,H)21 1.01 1.02 1.01 AHP42C3X – 1.00 1.00 1.00 F2RP/F2FP042 – 1.00 1.00 1.00 – G1FA048S21 1.01 0.99 1.01 – G1NA036S17L 1.03 1.05 1.03 – G1NA048S21D 1.03 1.05 1.04 – FC/MC/PC35*3X 1.01 0.99 1.01 – FC/MC/PC/UC36*3X 1.01 0.99 1.01 – FC/MC/PC-UC42*3X 1.01 0.99 1.01 – G1UA048S21 1.01 0.99 1.01 – G2FD042(S,H)21 1.01 1.02 1.01 Unitary Products Group 279104-YTG-B-0307 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. E2RA048S(25,46) INDOOR COIL MODEL NO. F2FP048 CONDENSER ENTERING AIR TEMPERATURE ID CFM 1300 1450 1550 ID DB (°F) 85 80 75 70 85 80 75 70 85 80 75 70 ID WB (°F) 72 67 62 57 72 67 62 57 72 67 62 57 75 T.C. 52.3 48.3 45.0 40.6 53.0 49.0 45.7 41.3 53.4 49.4 46.1 41.9 S.C. 32.5 32.8 31.7 33.5 34.0 34.3 33.2 35.1 35.0 35.2 34.1 36.3 KW 4.14 4.07 4.02 3.95 4.16 4.08 4.04 3.97 4.17 4.09 4.05 3.97 85 T.C. 50.9 47.0 43.7 39.4 51.5 47.6 44.4 40.3 51.9 48.0 44.7 40.6 S.C. 32.4 32.6 31.6 33.3 34.0 34.2 33.2 35.1 35.2 35.4 34.2 36.2 KW 4.44 4.36 4.30 4.22 4.46 4.38 4.32 4.24 4.47 4.38 4.33 4.2...

Other models in this manual:
Water and Air Pumps - 036-048 (231.72 kb)
Water and Air Pumps - 060 (231.72 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category