This output will drive any OMEGA® flow ratemeter, counter, controller or pulse input data acquisition board. Unpacking Remove the Packing List and verify that you have received all equipment. If you have any questions about the shipment, please call the Customer Service Department. When you receive the shipment, inspect the container and equipment for any signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent. NOTE The carrier will no
Phone: (717) 561-1105 Fax: (717) 561-1298 E-mail: OMEGAUS@aol.com OmegaProducts, Inc. Harrisburg, PA 17111 4523, U.S.A. Phone: (717) 561-1105 Fax: (717) 561-1298 E-mail: OMEGAUS@aol.com Omega. . . A Legendary Name In Fresh Juice E x t r a c t i o n . INSTRUCTION MANUAL FOR THE OMEGA JUICER 1000 AND 500 HOUSEHOLDANDCOMMERCIALUSE I M P O RTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed including the following: • Read all instructions. • To prote
This is done by using four connecting leads to the device and connecting the V+ and I+ leads to the anode and the V– and I– leads to the cathode as shown in Figure 1. The exact point at which the connecting leads are soldered to the device leads results in negligible temperature measurement uncertainties. In a two-wire measurement configuration, the voltage connections (point A in Figure 1) are made near or at the current source, so only two leads are actually connected to the device. Some loss
Box 4047 ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA® Customer Service: 1-800-622-2378 / 1-800-622-BEST® Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN® TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA Mexico: TEL: (00
To use the RS485 communication for the Signal Conditioners you’ll need an available Communication port in your computer and have access to a generic communication software program (e.g.: Procomm1, Windows2 HyperTerminal3, etc, see details below for information). A RS485 signal conditioner communication software program is also available as an option to speed the set-up. A RS232 to RS485 converter box will also be required if your computer communications port is RS232. 1 Procomm is a registered t
Install Jumper onto S1-A on Component Side of Board. Version A Version B Testpoint/Jumper Locations Page 5 IV. COMMANDS FOR ACCESSING EEPROM: NO. command letter index meaning # of bytes 1. R,W 01 Input range or function 1 2. R,W 02 Input/output Configuration 1 3. R,W 03 Decimal point 1 4. R,W 04 Filter time constant 1 5. R,W 05 Reading scale 3 6. R,W 06 Reading offset 3 7. R,W 07 Communication parameters 1 8. R,W 08 Communication bus format 1 9. R,W 09 Communication Data format 1 10. R,W 0A Comm
COMMUNICATION PARAMETERS: This is one byte data and specifies BAUD, PARITY, DATA, and STOP bit. BAUD = bits 2,1,0 are: 000-001 not used 010 for 1200 011 for 2400 100 for 4800 101 for 9600 110 for 19200 111 not used Page 12 PARITY = bits 4,3 and are: 00 for NO 01 for ODD 10 for EVEN 11 not used DATA BIT = bit 5 and is: 0 for 7 data 1 for 8 data STOP BIT = bit 6 and is: 0 for 1 stop 1 for 2 stop Bit 7 : always 0 Note 1: Stop bit is always 1. Unless 7 data, no parity is selected then unit will use
You can send another command after you receive the
You can send another command after you receive the