Frame the hole as shown in diagram 9. Note: For best results and optimum performance with each approved venting system, it is highly recommended to apply “Mill-Pac” sealant (supplied) to every inner pipe connection. Failure to do so may result in drafting or performance issues not covered under warranty. Silicone (red RTV) is optional. 4) Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the Round Support Box. Insure that all pipes and
If this is the case, you may want to adjust the location of the unit. 2) Assemble the desired combination of pipe and elbow to the appliance adapter with pipe seams oriented down. Offset the pipe seams as double seams in one place will cause the outer pipe to take an oval shape. Kit comes complete with 18" of straight vent -6-5/8" dia. black outer pipe and 4" dia. inner vent. 3) With the pipe attached to the stove, slide the stove into its correct location, and mark the wall for a 9-1/2"(insided
918-427a FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 Thank-you for purchasing a HAMPTON FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the HAMPTON DEALER in your area. Keep those HAMPTON FIRES burning. SAFETY NOTE: If this woodstove is not properly installed, a house fire may
Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fi re department. This appliance may only be installed in an aftermarket permanently located, manufactured (USA only) or mobile home, where not prohibited by local codes. FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapours and liquids in the vicinity of this or any other appliance. This appliance is only for use with the type of
Note: Must remove 4 screws from stove collar and rotate 130o to have collar facing straight back. Secure into place with 4 screws. VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney. See the Venting Arrangements chart below for minimum and maximum fl ue lengths. See chart bel
Dia. 4. 8) Connect all pipe sections to unit and install into wall: a) Measure pipe length required and cut to length. Hint: use the cut end of the 6-5/8" dia. outer pipe at the vent terminal end. b) Push the pipe sections completely together, the minimum pipe overlap is 1-1/4". Secure all outer pipe joints by using at least two screws. Locate the screws at the bottom of the pipe so that the screw heads are hidden on the fi nal installation. Apply sealant "Mill- Pac" to inner pipe and high temp
flex liner to the vent terminal ensuring that the flex overlaps the collar of the vent terminal by a minimum of 1-3/8"(35mm). Use Mill-Pac to seal and secure with 3 of the #8 x 1/2" screws (stainless steel). 4) Attach the adjustable pipe section to the vent terminal using Mill-Pac and/or high temperature silicone and attach with 3 of the #8 x 1/2" screws (stainless steel). NOTE: For best results and optimum performance with each approved venting system, it is highly recommended to apply “Mill-Pa
918-214c FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 Thank-you for purchasing a HAMPTON FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the HAMPTON DEALER in your area. Keep those HAMPTON FIRES burning. SAFETY NOTE: If this woodstove is not properly installed, a house fire may
OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the glass in the door frame is properly positioned. Never operate the appliance with the glass removed. Never strike the glass or slam the door shut. 5) Verify that the venting and cap are unobstructed. 6) Verify log placement. If the pilot cannot be LIGHTING PRO
Inc. Hampton® H35 Direct Vent Freestanding Gas Stove INSTALLATION ROTATING 45O ELBOW FOR STRAIGHT HORIZONTAL TERMINATIONS 1)Remove all 4 screws that secure 2) Rotate the elbow 180o the elbow to the unit using a 1/4" magnetic nut driver. 3) Secure the elbow by securing it with the 4 screws. Remove all 4 screws and washers VENTING ARRANGEMENTS Horizontal Terminations for All Venting Systems The shaded areas in the diagram below show all allowable combinations of vertical runs with horizontal termi