If the Bath Seat is not properly assembled and adjusted, personal injury and damage to the Bath Seat could result. WARNING: If components are damaged or missing, contact your dealer immediately. DO NOT use substitute parts. Use only Lumex replacement parts. Non-Lumex replacement parts could cause personal injury and damage to the Bath Seat. WARNING: This product has a weight limit of 350 lb. WARNING: DO NOT use this product as a transfer bench or climbing device. WARNING: GF Health Products, Inc
Los productos de Lumex son disenados y hechos a estandares precisos y son revisados cuidadosamente antes de envio. La Garantia Limitada de por Vida es un expresion de nuestro confianza en los materiales y factura de nuestros productos. Somos dedicados a proveer productos que pueden dar anos de servicio fiable a nuestros clientes. GF Health Products, Inc. garantia las partes especificos de estos modelos de Lumex escritos en el forro de este “hangtag” para la vida del producto sobre ser libre de d
WARNING: Make sure that all attaching hardware, screws, nuts and/or bolts are tight at all times. WARNING: Inspect rubber tips on the leg extensions for rips, tears, cracks or wear or if they are missing. Replace them IMMEDIATELY if any of these conditions exist. WARNING: The transfer bench seat MUST be installed before sitting on the transfer bench. WARNING: If components are damaged or missing, contact your GF Health Products Inc. distributor immediately. Transfer Bench Items 7927A and 7929 de
Locate the four remaining screw knobs and curved washers. a. 7921R (with backrest): The screw knobs will attach the backrest and outer legs to the seat. Install curved washers on screw knobs. Lay seat upside down on flat surface as shown in figure 7. Lay backrest tubes on leg assembly, aligning holes. Insert screw knobs through backrest tube holes, through leg assembly holes, and into seat bottom. Secure by turning screw knobs clockwise; ensure screw knobs are tight without overtightening. b. 79
If Sensor cord from mattress becomes disconnected from control unit while in Auto mode, alarm will sound. 3.2 MANUAL MODE Mattress inflation level user determined by Comfort Adjust (-, +) setting. The indicator adjacent to the icon will light while manual mode is active. 3.3 FLOAT MODE all cells within mattress will be uniformly inflated when this icon is illuminated. 3.4 AP MODE. (Alternating Pressure) Adjacent cells within mattress will be alternately inflated and deflated in this mode. The in
Only qualified medical service personnel should attempt to repair this device. A Service Manual is available for use by qualified personnel. For assistance contact your local dealer. If additional assistance is needed, contact the Graham Field Health Products technical service department. Domestic Customers: Toll Free: 1-800-347-5678 Fax: 1-800-726-0601 1.0 Warranty The Control Unit is warranted free of defects in material and workmanship for a period of two (2) years. The Mattress is warranted
3 INTENDED USE OF THIS DEVICE ........................................................ 3 IMPORTANT SAFETY PRECAUTIONS .................................................. 4 DANGER ................................................................................................. 4 WARNING ............................................................................................... 4 CAUTION ................................................................................................ 6 EQUIPMENT