downloaded: 0File size: 298 kb    Manafacture: Allstar Products Group  
Category: Doors and Windows

MOUNT THE PUSHBUTTON AT LEAST 5 FT FROM THE FLOOR, OUT OF REACH OF CHILDREN. 106495B2 Figure 2 Signal Sent Indicator Battery Hatch Mounting Screw Hole Keypress Indicator Mounting Holes PROGRAMMING INSTRUCTIONS 1 2 3 4 # # 1 1 2 1 3 1 2 1 3 2 # Default PIN DIP Switch Settings from Transmitter + 0 - 1 2 3 4 5 6 7 8 9 Figure 3 PROGRAMMING INSTRUCTIONS Write the settings of your transmitter DIP switches into the Transmitter Code table: 1 2 3 4 # # 1 # Factory Default Your Transmitter Code STEP 3: No

Allstar Products Group 3000

downloaded: 2File size: 1 mb    Manafacture: Allstar Products Group  
Category: Safety Gate

Bright transmitter LED's indicate operation and monitor battery condition. (Page 15) Deluxe Wall Push Button Station: A feature-packed accessory unit, Allstar's Deluxe Wall Push Button Station allows access to all of the Opener'sfunctions. The Opener's built-in light can be turned on or off independent of door operation. A Vacation Switch allows the Opener to be deactivated for extended periods of time. Lighted Push Buttons enhance nighttime use. (Page 16) Keyless Entry System: A tamper resistan

Allstar Products Group 3500

downloaded: 0File size: 1 mb    Manafacture: Allstar Products Group  
Category: Safety Gate

A small Plastic Pin is provided to secure the other end of the Receiver to the panel. For proper operation, the Antenna Wire should be POINTED STRAIGHT DOWN toward the floor. After installing the Radio Controls, check their operation by moving approximately 35 FT away from the garage door and pressing the Transmitter Button. Operation at this distance should be reliable. If the Transmitter doesn't activate door operation, check that all Coding Switches are set identically. If the operational dis

Allstar Products Group 3500-P

downloaded: 0File size: 1 mb    Manafacture: Allstar Products Group  
Category: Safety Gate

Close the door. If the down force adjustments are correct, the door will reverse within two seconds of contacting the object and travel to the Full Open position. If this does not occur, recheck the Limit Adjustments (Page 17) and Sensitivity Adjustments (Step 2 & 3, Above). NOTE: Any time adjustments are made to Limits or Sensitivity, YOU MUST RETEST THE OPENER FOR THE REVERSING FEATURE AT FLOOR LEVEL AS OUTLINED ABOVE. OPEN FORCE ADJUSTMENT CLOSE FORCE 104391 ADJUSTMENT 1 1/2” BLOCK OF WOOD LA

Allstar Products Group 535

downloaded: 3File size: 216 kb    Manafacture: Allstar Products Group  
Category: Radios

This is accomplished by setting the selector switch on the transmitter to either 1, 2, 3, 4, 5, 6, 7, 8 or 9 and setting the #7 and #8 coding switches in the 831 receiver. Start coding by exactly matching all 8 code switches in the transmitter and receivers. The code switches may be set in any random pattern of +, 0 and - positions. Next, in receiver 1, set code switch #7 to + and code switch #8 +; In receiver 2, set code switch #7 to + and code switch #8 to 0. Continue setting the codes in the

Allstar Products Group 6000

downloaded: 13File size: 1 mb    Manafacture: Allstar Products Group  
Category: Safety Gate

2 Product Features ................................................................................... 2 Component Identification/Tools Required ........................................... 4 Section A: Assembly Instructions ....................................................... 5 Section B: Installation Notes ................................................................ 6 Section C: Installing the Operator ....................................................... 7 Identify Your Door Type ....

Allstar Products Group 639

downloaded: 1File size: 216 kb    Manafacture: Allstar Products Group  
Category: Radios

Follow the directions on the next page for proper Transmitter/Receiver Coding! 733 Rotary Switch selects door A, B or C Slide Switch selects door A, B or C 8833C-OCS Rotary Switch selects door 1, 2, 3, ... or 9 639 Combination of both Rotary Switches selects door Examples: A1, B7, C9, etc. 831 STOP CLOSE OPEN 8833-OCS STOP CLOSE OPEN 535 COMMERCIAL TRANSMITTER MODELS Page 3 of 4 P/N 107343 Rev D The information below indicates how to set the coding switches in the various transmitters and receiv

Allstar Products Group 6500

downloaded: 2File size: 1 mb    Manafacture: Allstar Products Group  
Category: Safety Gate

Use a minimum 22 gauge solid "trace" wire for interconnect. C. Run a wire pair (20 or 22 gage solid wire) from the receiver position (unit with "LED" light in the front, may be either side of the door) back to the rear bulkhead of the garage door opener. NOTE: Leave about 12” of extra wire at the receiver end and about 24” of extra wire at the opener end. D. Strip approximately 5/16” from each wire end at the photosystem units and at the opener. E. Using two (2) wire nuts (supplied), connect the

Allstar Products Group 6500-P

downloaded: 0File size: 1 mb    Manafacture: Allstar Products Group  
Category: Safety Gate

If the down force adjustments are correct, the door will reverse within two seconds of contacting the object and travel to the Full Open position. If this does not occur, recheck the Limit Adjustments (Page 17) and Sensitivity Adjustments (Step 2 & 3, Above). NOTE: Any time adjustments are made to Limits or Sensitivity, YOU MUST RETEST THE OPENER FOR THE REVERSING FEATURE AT FLOOR LEVEL AS OUTLINED ABOVE. OPEN FORCE ADJUSTMENT CLOSE FORCE 104391 ADJUSTMENT 1 1/2” BLOCK OF WOOD LAID FLAT (2”X4”)

Allstar Products Group 733

downloaded: 1File size: 216 kb    Manafacture: Allstar Products Group  
Category: Radios

• LOCATE CONTROL PUSHBUTTONS WITHIN SIGHT OF THE DOOR AND AWAY FROM THE MOVING PARTS OF THE DOOR. INSTALL ENTRAPMENT WARNING LABEL NEXT TO THE CONTROL PUSHBUTTON IN A PROMINENT LOCATION. • REMOVE ALL ROPES AND REMOVE OR MAKE INOPERATIVE ALL LOCKS CONNECTED TO THE GARAGE DOOR. • THE IMPORTANT SAFEGUARDS AND INSTRUCTIONS IN THIS MANUAL CANNOT COVER ALL POSSIBLE CONDITIONS AND SITUATIONS. IT MUST BE UNDERSTOOD THAT COMMON SENSE AND CAUTION MUST BE EXERCISED BY THE PERSON(S) INSTALLING, MAINTAINING