Login:
Sorted: Name ↑   Downloads   Rate   Size ↑  

Weil-McLain WMVSA126NH5R

downloaded: 11File size: 288 kb    Manafacture: Weil-McLain  
Category: Electric Heaters

Please review installation manual.

Weil-McLain WMVSA108NH5R

downloaded: 6File size: 288 kb    Manafacture: Weil-McLain  
Category: Electric Heaters

Please review installation manual.

Weil-McLain WMVSA090NH4R

downloaded: 8File size: 288 kb    Manafacture: Weil-McLain  
Category: Electric Heaters

Please review installation manual.

Weil-McLain WMVSA090NH3R

downloaded: 1File size: 288 kb    Manafacture: Weil-McLain  
Category: Electric Heaters

Please review installation manual.

Weil-McLain WMVSA072NH4R

downloaded: 7File size: 288 kb    Manafacture: Weil-McLain  
Category: Electric Heaters

VENT OUTLET 28 13/16 1/2 29 3/16 24 I Up-Flow Models 90.9% AFUE Plenum Openings 1 I Model I BTUH (input) I BTUH (output) Max Cooling Tons Blower (Direct Drive) Shipping Weight (lbs) Cabinet Width (A) Supply (C) Return (B) 1 High Speed Vent Size Inches* I Width Depth I Width I Depth “I UhM @ Ü.0 Inches W.C. I Motor (HP) I Size I Intake I Exhaust WMVSA054NH3R I 54,000 I 49,300 3 1/3 10-6 122 171/2" 15 15/16" 18 15/16" I 153/4" i 8 7/8" 1,140 I 2 2 W

Weil-McLain WMVSA072NH3R

downloaded: 4File size: 288 kb    Manafacture: Weil-McLain  
Category: Electric Heaters

VENT OUTLET 28 13/16 1/2 29 3/16 24 I Up-Flow Models 90.9% AFUE Plenum Openings 1 I Model I BTUH (input) I BTUH (output) Max Cooling Tons Blower (Direct Drive) Shipping Weight (lbs) Cabinet Width (A) Supply (C) Return (B) 1 High Speed Vent Size Inches* I Width Depth I Width I Depth “I UhM @ Ü.0 Inches W.C. I Motor (HP) I Size I Intake I Exhaust WMVSA054NH3R I 54,000 I 49,300 3 1/3 10-6 122 171/2" 15 15/16" 18 15/16" I 153/4" i 8 7/8" 1,140 I 2 2 W

Weil-McLain WMVSA054NH3R

downloaded: 1File size: 288 kb    Manafacture: Weil-McLain  
Category: Electric Heaters

VENT OUTLET 28 13/16 1/2 29 3/16 24 I Up-Flow Models 90.9% AFUE Plenum Openings 1 I Model I BTUH (input) I BTUH (output) Max Cooling Tons Blower (Direct Drive) Shipping Weight (lbs) Cabinet Width (A) Supply (C) Return (B) 1 High Speed Vent Size Inches* I Width Depth I Width I Depth “I UhM @ Ü.0 Inches W.C. I Motor (HP) I Size I Intake I Exhaust WMVSA054NH3R I 54,000 I 49,300 3 1/3 10-6 122 171/2" 15 15/16" 18 15/16" I 153/4" i 8 7/8" 1,140 I 2 2 W

Weil-McLain UO-5 CV

downloaded: 0File size: 1 mb    Manafacture: Weil-McLain  
Category: Convection Ovens

The trial for ignition (lockout) time expired withoutflame being established. b. The cad cell detected flame at the end of the Valve On Delay state. To reset the control from lockout click the button 1 second. NOTE: A recurrence of the above failure modes or a failed welded relay check could cause the control to enter a Hard Lockout state that must be reset onlyby a qualified service technician. To reset from Hard Lockout, hold the reset button for 15 seconds until the yellow light turns on. 5.

Weil-McLain UO-4 CV

downloaded: 0File size: 1 mb    Manafacture: Weil-McLain  
Category: Convection Ovens

• Some steel chambers may not require liners because the appliance was designed and tested for use with flame retention burners. Refer to the manufacturer’s instructions. Combustion chamber — Burner retrof tting Verify that the appliance combustion chamber provides at least the minimum dimensions given in Table 3. Table 3. Chamber Dimensions Chamber Dimensions (inches) Firing Rate (GPH) Round I.D. Rectangular Height Floor to nozzleWidth Length 0.50 8 7 8 12 5-6 0.75 9 8 9 12 5-6 1.00 10 9 10 12.

Weil-McLain UO-3 CV

downloaded: 2File size: 1 mb    Manafacture: Weil-McLain  
Category: Convection Ovens

Save this manual for future reference. ...... Incorrect installation, adjustment, or misuse of this burner could result in death, severe personalinjury, or substantial property damage. To the Professional, Qualif ed Installer or Service Agency: Please read and carefully follow all instructions provided in this manual before installing, starting, or servicing this burner or heating system. The Installation must be made in accordance with all state and local codes having jurisdiction. .... AF/AFGA





Category