CLAMP 1 35 BRACKET, WATER OUTLET VALVE 1 36 85018 DECAL, KEYPAD OVERLAY 1 37 83745 7/16-20 FEM x 7/16-20 MALE 1 39 8552-18 TERMINAL BLOCK 240V 1 40 83571 INSERT, SPRAYHEAD 1 41 83763 82936 SWITCH 120V SWITCH, ROCKER ON-OFF 240V 1 ITEM PART # DESCRIPTION QT 42 66385 9012-38 FITTING, CONDUIT 3/4" STR 240V STRAIN RELIEF LIQ. TIGHT 120V 1 43 63046 PLUG, HOLE 1" 120V 1 45 8033-56 CAP LEVELER 4 46 8033-55 LEG LEVELER PLATED 4 48 83571 INSERT, SPRAY HEAD 1 50 83810 BRACKET POSITIONING 1 51 63201 SPACER
View Water Temperature in Tank: To view the water temperature on the screen, the E-Max™ brewer must be ON, and not brewing or in the filling mode. Press and hold the 4th key, and depress the 6th key. The actual water temperature will be displayed for 3 seconds. 2. Daily Brew Count: The E-Max™ maintains a count of the number of completed brews for a 7-day period. To access the count, turn the brewer OFF. In the OFF mode, press and hold the CANCEL key for 3 seconds. The current day and brew count
Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED: 1. VISIBLE LOSS OR DAMAGE: Be certain that any visible loss or damage is noted on the freight bill or express receipt, and that the note of loss or damage is signed by the delivery person. 2. FILE CLAIM FOR DAMAGE IMMEDIATELY: Regardless of the extent of the damage. 3. CONCEALED LOSS OR DAMAGE: if damage is unnoticed until the merchandise is unpacked, notif
14) Water filter (if used) plugged Replace filter element Bad BREW switch Replace switch Damaged internal component or Examine wiring & connectors, wiring brew switch and solenoid Repair/replace as needed No flow from hot water faucet Faucet valve turned OFF Turn faucet valve ON Faucet plugged Disassemble faucet, clean Poor coffee quality Water not hot enough Adjust water temp 195-205.F Keep brewer, airpots and servers clean. Install a taste and odor filter in water supply, and replace cartridge
SOLENOID STRAINER WASHER INLET FITTING CAP (note orientation DO NOT REVERSE) FILL SOLENOID FLOW CONTROL (installed) LID TANK GASKET CLIP LID GASKET 12 SERVICING INSTRUCTIONS PLUMBING 13 ITEM DESCRIPTION PART N0. USED ON 1 2 ASSEMBLY, WATER TANK (120V) 83500 2212, 2272 6 GASKET, TANK LID 83499 ALL 9 TANK LID 83504 ALL 10 RETAINING CLIP, TANK LID 83506 ALL 11 HOSE, OVERFLOW (2 pc SILICONE 4.5” LONG) 86014 ALL 12 HOSE, FAUCET SUPPLY (SILICONE, 10” LONG) 83538 ALL 13 TUBE, VENT (METAL, 2.3” LONG) 83
CLAMP 1 35 BRACKET, WATER OUTLET VALVE 1 36 85018 DECAL, KEYPAD OVERLAY 1 37 83745 7/16-20 FEM x 7/16-20 MALE 1 39 8552-18 TERMINAL BLOCK 240V 1 40 8043-11 ELBOW, VENT 1 41 83763 82936 SWITCH 120V SWITCH, ROCKER ON-OFF 240V 1 ITEM PART # DESCRIPTION QT 42 66385 9012-38 FITTING, CONDUIT 3/4" STR 240V STRAIN RELIEF LIQ. TIGHT 120V 1 43 63046 PLUG, HOLE 1" 120V 1 45 8033-56 CAP LEVELER 4 46 8033-55 LEG LEVELER PLATED 4 48 83571 INSERT, SPRAY HEAD 1 50 83810 BRACKET POSITIONING 1 51 63201 SPACER 4 C
To reset press and hold CANCEL for 3 seconds, or re-energize the brewer. (Possible causes of the problem are: no incoming water; slow flow of incoming water, sensor not reading, etc.). E. Keyswitch Locked: If a key switch is depressed for 10 seconds this error message will occur. Lights will flash alternately and the brewer will turn off all valves and elements. Press and hold the CANCEL key for 3 seconds to reset the brewer (or re-energize the brewer). If the problem re-occurs this indicates a
5 E9253 E9253 STD 4 OPERATION OPERATION OPERATING INSTRUCTIONS IMPORTANT: All E-Max™ brewers are tested and set at the factory. If programming adjustments are necessary, refer to the E-Max™ Programming Manual (p/n/73674). To over-ride the Brew Wait mode, press and hold the BREW key for 3 seconds when the brewer is in Brew Wait mode (i.e. when brew light is flashing). The brew will proceed immediately regardless of water temperature. This feature should only be used when testing water volume, oth
This manual and all supplied instructions, diagrams, schematics, parts breakdown illustrations, notices and labels must remain with the appliance if it is sold or moved to another location. This appliance is made in the USA. Unless otherwise noted, this appliance has American sizes on all hardware. This unit complies with NSF standard 4 only if maintained and operated per the instructions in this manual. This unit is Underwriters Laboratory listed under E6070. WARNING: ELECTRIC SHOCK HAZARD All
These times are only approximate and will vary depending on the darkness setting. Your own experience with your product is your best guide to the best darkness setting. The slide rack raises automatically at the end of the timed cycle. Slide racks may be manually raised at any time during the timed cycle by lifting the slide knob. Each successive toasting cycle will require less time as the toaster chamber retains more heat. Adjust the darkness knob as required to maintain your desired toast col