Login:
Sorted: Name ↑   Downloads   Rate   Size ↑  

Energy Tech Laboratories DHG180

downloaded: 49File size: 419 kb    Manafacture: Energy Tech Laboratories  
Category: Air Conditioner & Split Systems

UNITS, TANKS AND PIPING .......................10 VENT AND COMBUSTION AIR HOODS..................11 OPT ECONO/MOTORIZED DAMPER RAIN HOOD .........11 ENTHALPY SET POINT ADJUSTMENT........................11 PWR EXH/BARO RELIEF DMPR & RAIN HOOD OPT.......11 OPERATION ...................................19 COOLING SYSTEM ..................................19 PRELIMINARY OPERATION COOLING ..................19 COOLING SEQUENCE OF OPERATION .................19 NO OUTDOOR AIR OPTIONS ............

Energy Tech Laboratories 5356

downloaded: 47File size: 2 mb    Manafacture: Energy Tech Laboratories  
Category: Water and Air Pumps

WARNING: Indicates the presence of hazards or unsafe practices which could cause severe personal injury, death or substantial property damage if ignored. CAUTION: Indicates the presence of hazards or unsafe practices which could cause minor personal injury or product or property damage if ignored. NOTE: Indicates special instructions on installation, operation, or maintenance which are important but not related to personal injury hazards. This manual, as well as the pool/spa heat pump pool heate

Energy Tech Laboratories DSH

downloaded: 25File size: 2 mb    Manafacture: Energy Tech Laboratories  
Category: Air Conditioner & Split Systems

Each of these items has the potential, if misused or handled improperly, to cause bodily injury or death. It is the obligation and responsibility of operating/service personnel to identify and recognize these inherent hazards, protect themselves, and proceed safely in completing their tasks. Failure to comply with any of these requirements could result in serious damage to the equipment and the property in which it is situated, as well as severe personal injury or death to themselves and people

Energy Tech Laboratories New Yorker F3

downloaded: 23File size: 3 mb    Manafacture: Energy Tech Laboratories  
Category: Water Heaters

has determined that the CL3-091, CL3-105, CL4-126 and CL5-168 water boilers meet the ENERGY STAR® guidelines for Energy efficiency established by the United States Environmental Protection Agency (EPA). For service or repairs to boiler, call your heating contractor. When seeking information on boiler, provide Boiler Model Number and Serial Number as shown on Rating Label. Boiler Model Number CL Boiler Serial Number Installation Date Heating Contractor Phone Number Address 100825-01R5-10/08 Price

Energy Tech Laboratories POOL & SPA 6310

downloaded: 21File size: 1 mb    Manafacture: Energy Tech Laboratories  
Category: Water and Air Pumps

NOTE: The instructions in this manual are for the use of qualified individuals specially trained and experienced in the installation and maintenance of this type of equipment and related system components. Installation and service personnel are required by some states to be licensed. Persons not qualified shall not attempt to install, service, or maintain this equipment. This manual should be maintained in legible condition and kept adjacent to the heat pump pool heater or in a safe place for fu

Energy Tech Laboratories 6357

downloaded: 19File size: 2 mb    Manafacture: Energy Tech Laboratories  
Category: Water and Air Pumps

To Increase the Desired Water Temperature (Pool or Spa Mode) Push the SET key until you see POL or SPA. The programmed temperature will be displayed. Press the UP arrow to increase the temperature setting one degree at a time. To Lower the Desired Water Temperature (Pool or Spa Mode) Push the SET key until you see POL or SPA. The programmed temperature will be displayed. Press the DOWN arrow to decrease the temperature setting one degree at a time. Once the control has been programmed to the des

Energy Tech Laboratories DHG240

downloaded: 18File size: 419 kb    Manafacture: Energy Tech Laboratories  
Category: Air Conditioner & Split Systems

All internal unit resistances have been deducted from the total static pressure of the blower. The Factory Setting 5 Unitary Products 17 035-17233-000-C-0702 TABLE 13: STATIC RESISTANCES1 RESISTANCE, IWG CFM 15 TON 20 TON 4500 5765 7200 6000 7000 9400 WET COIL 0.1 0.1 0.1 0.1 0.1 0.1 ECONOMIZER OPTION 0.1 0.1 0.1 0.1 0.1 0.1 HORIZONTAL DUCT CONN.2 0.2 0.3 0.5 0.2 0.3 0.5 1 Deduct these resistance values from the available unit ESP values listed in the respective blower perfor

Energy Tech Laboratories 5357

downloaded: 13File size: 2 mb    Manafacture: Energy Tech Laboratories  
Category: Water and Air Pumps

This condensation drains from the bottom of the unit. 1. Routinely check to be sure the condensation drain holes in the base of the unit are not plugged with dirt or debris. 2. If condensation becomes a problem, optional drain pans are available from your heat pump pool heater distributor or pool dealer. 9 Troubleshooting If your unit does not operate, or simply does not heat your pool water, Fault Codes on the front control panel, can provide valuable clues as to what is wrong, and may even ind

Energy Tech Laboratories FEMP Clothes Washer

downloaded: 11File size: 233 kb    Manafacture: Energy Tech Laboratories  
Category: Washers

Clothes Washers Performance Requirement for Federal Purchases Washer Capacity Modified Energy Factora 1.6 to 3.5 cu. ft. 1.42 or more a) Modified Energy Factor (MEF) is the number of cubic feet of clothes washed and dried per kilowatt hour (kWh) of electricity used. MEF is calculated by dividing the tub capacity by the total energy (clothes washer, water heater and dryer) used per wash load (10 CFR 430, sub-part B, Appendix J). Buying Energy-Efficient Clothes Washers When buying residential and

Energy Tech Laboratories 8357

downloaded: 11File size: 2 mb    Manafacture: Energy Tech Laboratories  
Category: Water and Air Pumps

To do so may result in an explosion or fire. NOTE: The instructions in this manual are for the use of qualified individuals specially trained and experienced in the installation and maintenance of this type of equipment and related system components. Installation and service personnel are required by some states to be licensed. Persons not qualified shall not attempt to install, service, or maintain this equipment. This manual should be maintained in legible condition and kept adjacent to the he





Category