Login:
Sorted: Name ↑   Downloads   Rate   Size ↑  

Desa JW717

downloaded: 51File size: 339 kb    Manafacture: Desa  
Category: Water Heaters

HOT OUTLET EXPANSION TANK (OPTIONAL) MIXING VALVE COLD INLET CHECK VALVE (IF USED REQUIRES EXPANSION TANK) HOSE BIB (OPTIONAL) FLOW CONTROL SUPPLY RETURN CHECK VALVE EXTERNAL CIRCULATOR HYDRONIC IN-FLOOR LOOP FIXTURE Figure 15 COMBO HEATING - IN-FLOOR LOOP C H M HOT WATER TO HOUSE COLD SUPPLY EXTERNAL CIRCULATOR HOSE BIB (OPTIONAL) BASEBOARDS (SERIES CON WATER HEATER 8in TO 12in MAX. HOT OUTLET EXPANSION TANK (OPTIONAL) MIXING VALVE COLD INLET CHECK VALVE (IF USED REQUIRES EXPANSION TANK) FLOW C

Desa S39PT

downloaded: 43File size: 804 kb    Manafacture: Desa  
Category: Kitchen-ranges

Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts. IMPORTANT: Do not provide

Desa 5 (70

downloaded: 30File size: 1 mb    Manafacture: Desa  
Category: Fans

KEY NO. PART NUMBER PART DESCRIPTION QTY. KEY NO. PART NUMBER PART DESCRIPTION QTY. 1 2 3 4 5 6 7 88-1 8-2 8-3 8-4 8-5 8-6 8-7 8-8 9 10 11 12 13 14 15 16 17 18 19 20 21 2222-1 22-2 22-3 22-4 22-5 098511-68 098511-58 098068-01 098512-02 M16660 HA3019 099125-02 M10908-2 ** M18022 M10659-1 M10809-1 M8882 M50924-01 M50820-02 079685-01 M10962-2 M11084-27 M19630 M16790-12 M50660-05 M15823-27 M16871 M17920 M50814-03 M50873-01 NPC-4C WLM-4C M16661 M51043-01 ** 098784-02 M8645-3 FHPF3-7C M22009 M22456-3

Desa TB111

downloaded: 28File size: 4 mb    Manafacture: Desa  
Category: Air Conditioner & Split Systems

Note: Motor will go into shell first (see Figure 8). 9. Line up rear mounting holes in shell with first hole on each side of motor mount (see Figure 8). Note: When holes are lined up, fan should be outside of shell. 10. Holding mounting screws, carefully reach through fan blades into rear of heater. Be careful not to damage fan pitch. Insert screw through motor mount and shell. With free hand, attach screw finger tight. Repeat process for other mounting hole. 11. Use 1/8" hex wrench to loosen se

Desa EL-7 14-inch

downloaded: 26File size: 955 kb    Manafacture: Desa  
Category: Chainsaws

Example:If lower notch cut is 20 centimeters deep (eight inches), start upper notch cut 20 centimeters (eight inches) above it. Cut downward at 45° angle. The upper notch cut should meet end of lower notch cut (see Figure 12, page 11). 3. Remove tree trunk wedge created by notching cuts. Felling Cut 1. Make felling cut five centimeters (two inches) higher than lower notch cut and on opposite side of tree (see Figure 12, page 11). Keep felling cut parallel to lower notch cut. 2. Cut towards notch

Desa TB114 125

downloaded: 26File size: 4 mb    Manafacture: Desa  
Category: Air Conditioner & Split Systems

When ordering parts, follow the instructions listed under Replacement Parts on page 11 of this manual. TB103 TB108 TB113 Key No. Part No. Description Qty. 1 118476-01 Handle • • • 1 2 118770-01 Control Box • • • 1 3 M11143-2 Strain Relief Bushing • • • 1 4 098219-42 Power Supply Cord Assembly • • • 1 5 118767-01 Fuel Tube • • • 1 6 100146-01 Female Elbow • • • 1 7 118685-04 Injector • • • 1 8 M50114-02 Male Elbow • • • 1 9 114159-04 Ball Valve Assembly • • • 1 10 113810-01 Ball Valve Knob Insert

Desa 280-IF

downloaded: 25File size: 3 mb    Manafacture: Desa  
Category: Air Conditioner & Split Systems

. OPERATING INSTRUCTIONS START 1. Fill tank - Use only kerosene, #1 & #2 diesel and fuel oil, JET A or JP-8 fuels. 2. Plug power cord into 120V/60Hz outlet. Power indicator light should be on. 3. If equipped, adjust thermostat knob to the warmest setting. 4. Push ON/OFF switch to ON () . Fan motor should start immediately. Heater will ignite within 10 seconds. 5. If equipped, adjust thermostat to desired setting. STOP Push ON/OFF switch to OFF (O). Fan motor will continue to run. Do not unplug h

Desa RJ70

downloaded: 25File size: 366 kb    Manafacture: Desa  
Category: Air Conditioner & Split Systems

Check circuit breaker in electrical panel is plugged in and switched ON WARNING: High voltage! 2. Bad electrical connection between mo-2. Check all electrical connections. See tor and ignition control assembly or ig-Wiring Diagrams, page 12 nition assembly and power cord 3. Binding pump rotor 3. If fan does not turn freely, see Pump Rotor, page 11 4. Defective ignition control assembly 4. Replace ignition control assembly 5. Defective motor 5. Replace motor 6. Defective ON/OFF switch 6. Replace

Desa (V)KC36P

downloaded: 25File size: 2 mb    Manafacture: Desa  
Category: Fireplaces

Follow the gas supplier's instructions • if you cannot reach you gas supplier, call the fire department. 4. Never install the fireplace • in a recreational vehicle • in windy or drafty areas where curtains or other combustible(flammable) objects can make contact with the fireplacefront • in high traffic areas 116226-01A 33 116226-01A SAFETY INFORMATION Continued PRODUCT IDENTIFICATION Figure 1 - Direct-Vent Fireplace with Millivolt Ignition LOCAL CODES Install and use fireplace with care. Follow

Desa Becton Bunny

downloaded: 24File size: 525 kb    Manafacture: Desa  
Category: Fireplaces

Manual AFS1125 AFS1125 21. Feet and Fixings AFS1013 AFS1013 22. Aarrow Fires Gauntlet Gloves AFS997 AFS997 Becton Bunny & Becton 7 MK3 Gas stoves GUARANTEE GUARANTEE Once again we would like to thank you for buying a Becton fire. When you buy an Aarrow Fire, you are not only buying a first class appliance - you are buying a commitment from us to look after you and your appliance. The Becton Gas Stoves come with a Lifetime Guarantee against splitting or cracking of the main body. The main body be