Refer to National Fuel Gas Code, ANSI Z223.1 1992, Section 5.3. b. Vent room directly to the outdoors. Refer to National Fuel Gas Code, ANSI Z223.1 1992, Section 5.3. c. Install a lower BTU/Hr heater, such as a 21,000 BTU/Hr, to make the area an unconfined space. If the actual BTU/Hr used is less than the maximum BTU/Hr the space can support, then the space is an unconfined space. You will need no additional fresh air ventilation for an unconfi ned space. COLD CLIMATE INSULATION For cold climate
Before the operation of the vent system can be tested, the lever securing screw must be removed (see Figure 20). The hand operated outside air control lever is located on the left side of the fi replace opening (see Figure 20). STEP 7. INSTALLING OUTSIDE AIR KIT Optional outside make-up air kits, Model FOAK-4 or FAOK-4LD (see Figure 21 on Page 14), may be used with these appliances. Refer to the installation instructions packaged with the air kits for specifi c installation information. If used,
b. Stack wood loosely to allow air circulation. c. Store wood where it will not be excessively exposed to weather, such as under a tarp or under a roof. d. Do not stack wood directly against the walls of your home. 8. Be a knowledgeable wood buyer. There is a difference in cord sizes. A standard cord stack of logs is 4 ft. high by 8 ft. long by 4 ft. deep or the equivalent of this cubic footage, (Figure 1). 8' Standard Cord of Wood 4' 4' Figure 1 A face cord is the same height and length as a st
For elevations above 4500 feet, contact your gas supplier or qualified service technician. Install the appliance according to the regulations of the local authorities having jurisdiction and, in the USA, the National Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest edition or , in Canada, the CAN1- B149.1 and .2 codes - latest edition. Gas Pressure - All Models Tables 2 and 3 show the appliances' inlet and manifold gas pressure. New York and Massachusetts requirements These appliances may be install
However, if not correct, you could experience an unusual downdraft. Usually, the best solution is to increase the chimney height. This may also be necessary if nearby trees, adjoining roof lines or a hill is causing a downdraft condition. 9. Remember, your fireplace has been designed as a supplemental heating device only, it is not intended to heat your entire home. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 6 WARRANTY This fireplace is covered by a limited warranty detailed separately
• The individual manual shut-off must be a T-handle type valve. NEW YORK CITY APPROVAL New York City, NY (MEA) These fireplaces are approved for installation in New York City in the US state of New York if the following additional requirement is met: • An Outside Combustion Air Kit (FOAK-4, FOAK-4LD, or DK-4) must be installed. See Step 5 on Page 14. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. SUPERIORSUPERIORB-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS COLd C
b.Position the bottom of the doorframe so that the bracket on the inside of the doorframe locks behind the cabinet bottom flange as shown in Figure 4. *c. Feed the switch wires through the switch mounting bracket on doorframe as shown in Figure 3. Retain the lower panel for future use in case the Style View Door Kit is ever removed. Wires for ON/OFF switch Switch Mounting Bracket on Doorframe Remove this lower panel by lifting it up and out. Figure 1 Figure 3 Tabs engage into slots (both sides)
Please read and understand these instructions before beginning your installation. Do not alter or modify the fireplace or its components under any circumstances. Any modification or alteration of the fireplace system, including but not limited to the fireplace, chimney components and accessories, may void the warranty, listings and approvals of this system and could result in an unsafe and potentially dangerous installation. IMPORTANT! TO ASSURE PROPER ALIGNMENT OF GLASS DOORS: INSTALL THIS FIRE
A vacuum can be used to remove any dust accumulation on the blower’s blades or inside the blower duct. Caution should be used not to damage the blower’s blades during cleaning. To reinstall the blower, slide the blower back into the retaining lip B and retighten screws A. A Adjustable Hopper The Winslow™ PI40 insert is shipped with the 55 pound hopper. With the larger hopper installed, that part of the insert that slides into the fireplace is 22-1/2” (572 mm) high. For installations in smaller f
This information will help you obtain safe and dependable service from your Superior fireplace system. Keep this document in a safe place for future reference. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Before you start your first fire, read this Care and Operations Manual carefully to be sure you understand your fireplace system completely. Failure to follow these suggestions could result in hazardous operation or fireplace malfunction, creating a serious potential for personal injury and/