HP PCI Tachyon TL/TS/XL2 Fibre Channel Driver Release Notes
Known Problems and Workarounds
Known Problems and Workarounds
Following is the known problem and workaround in the HP PCI Tachyon TL/TS/XL2 Fibre Channel driver:
•
Problem: The A6795A Fibre Channel adapter settles in the Public Loop topology as opposed to the Point
to Point Fabric topology when connected to a 4Gb Fibre Channel Brocade Switch port.
Symptom: The /opt/fcms/bin/fcmsutil /dev/
expected PTTOPT_FABRIC output, against the Topology field.
The /dev/
to the 4Gb Brocade Switch port.
Workaround: Configure the Brocade switch port that is connected to the A6795A Fibre Channel adapter, as G port.
Use the telnet command to connect to the switch. To enable the G port settings, enter the following command at the
switch prompt:
switch> portcfggport
The following message is displayed at the switch prompt:
Committing configuration...done.
For more information about the portcfggport command, use the help command:
switch> help portcfggport
For detailed information about the portcfggport command, see the manpage and Release Notes for the
Brocade switch present at:
http://www.brocade.com/index.jsp
To turn off the G port settings, enter the following command at the switch prompt:
switch> portcfggport
The following message is displayed at the switch prompt:
Committing configuration...done.
Chapter 1
13
...
Category
Search
Last visited
- Acer PCI to Ultra 160 SCSI RAID Controller AcceleRAID 170
- HP J3169A Surestore CD-ROM Server/Tower
- HP HP AiO600 1.8TB SAS Smart Buy Storage System
- HP HP 3PAR StoreServ 7450 4-node Base
- HP HP X5520 G2 10.8TB SFF 10K Network Storage System
- Livescribe LIVESCRIBE DESKTOP VERSION 1.2
- HP HP 82B 8Gb 2-port PCIe Fibre Channel Host Bus Adapter
- HP HP SAN Virtualization Services Platform Business Copy SW 1TB 101-250TB E-LTU
- HP HP 3PAR StoreServ 7400 2-node Storage Base for Storage Centric Rack
- HP HP D2600 Disk Enclosure