Other manuals for this model:
manual abstract
Table 15 FibrChanl-01 (fcd) Driver Version History (continued)
September 2006
B.11.11.09 (64-bit)
June 2006
B.11.11.08 (64-bit)
December 2005
B.11.11.07.01 (64-bit)
September 2005
B.11.11.06 (64-bit)
March 2005
B.11.11.05 (64-bit)
December 2004
B.11.11.04 (64-bit)
June 2004
B.11.11.03 (64-bit)
December 2003
B.11.11.02 (64-bit)
September 2003
B.11.11.01 (64-bit)
Known Problems and Limitations
This section provides a list of known problems and limitations as known to HP at time of this
publication. If there is any corrective actions to address the issue, it appears accordingly.
•
OnlineDiag Error when Using info Option
A problem may occur on Fibre Channel ports controlled by the fcd driver. The September
2005 version of the OnlineDiag bundle contains a version of STM that will show errors when
using the info option, when run against HBAs that are claimed by the fcd driver. STM fails
with messages such as Tool is exiting due to receipt of an unexpected
signal (11).
Corrective Action: Run /opt/fcms/bin/fcmsutil
•
Using ioscan with krm Not Running
When ioscan is run with the —fn or —Fn option, and the kernel resource monitor (krm) is
not running, there could be stale krm device files in the system, which would correspond
to different devices, including fcd, in ioscan output. This issue has no impact on the
functionality of the Fibre Channel port; however, ioscan output may be confusing. This
issue can impact any card accessible with ioscan, and is not specific to the cards supported
by the fcd driver.
Corrective Action:The ioscan output can be returned to normal by either deleting the stale
krm device files, or by starting krm, which will recreate the device files.
Compatibility and Installation Requirements
This section describes the compatibility information and installation requirements for this release.
For specific installation instructions, refer to the installation guide specific to your to your
FibreChannel card.
Operating System and Version Compatibility
The following software (or later versions) must be installed before installing the FibrChanl-01
(fcd) driver, version B.11.11.16, into a system:
•
Driver FibrChanl-00 (td) version B.11.11.16 or later for HP-UX 11i v1 (needed for SNIA-API)
•
OnlineDiag bundle, product number B6191AAE, version A.47.00 (B.11.11.16.xx) or later
•
PHKL_28569 needed for WSIO
•
PHKL_28695 needed for VM
•
PHKL_34161 needed for fcmsutil
•
PHKL_30067 only needed on systems with PCI-X slots
Known Problems and Limitations
9
...
Network Equipment - HP-UX 11i v1 I/O Cards (300.6 kb)