# FibrChanl-00 B.11.11.15 PCI/HSC FibreChannel;Supptd HW=A6684A,A6685A,A5158A,A6795A
FibrChanl-00.FC-TACHYON-TL B.11.11.15 PCI/HSC FibreChannel;Supptd HW=A6684A,A6685A,A5158A,A6795A
Known Problems and Workarounds
Following are the known problems and workarounds in the HP PCI Tachyon TL/TS/XL2
Fibre Channel driver:

Problem: During online replacement (OLR) of the A6795A adapter in Superdome
systems, the replacement can fail if the adapter is connected to the hub, switch, or
device, and the following error message is displayed:
OLARD error: General error
The slot is inaccessible till you power cycle the system.
Workaround: Disconnect the cable from the adapter before you perform online
addition and replacement (OLAR) operations.

Problem: During online replacement (OLR) of the A6795A adapter on L3000
systems, the replacement can cause a system panic (high-priority machine check
(HPMC)) if the adapter is connected to the hub, switch, or device. The subsequent
boot hangs unless you power cycle the system.
Workaround: Disconnect the cable from the adapter before you perform the OLAR
operations.

Problem: During online replacement (OLR) of the A6795A adapter on the L2000
system, the replacement may fail and the following error message may be displayed:
OLARD error: General error
Workaround: This problem is fixed in Processor Dependent Code (PDC) Version
41.38.
Defects Fixed in This Release
Table 1-2 lists the defects fixed in this release of the Fibre Channel PCI Tachyon
TL/TS/XL2 driver.
Table 1-2 Defects Fixed in the HP-UX 11i v1 Operating System
Number
Description
QXCR1000800100
SNIA HBA library returns the target mapping details for an
unpresented XP lun while the target mapping details of an
unpresented EVA lun are not returned. This results in incorrect
information in the bindings information provided for an HP-UX
host in Storage Essentials. The SNIA HBA library has been fixed
so that it does not return the target mapping details of any
unpresented luns.
QXCR1000792409
When the SNIA API tries to open any LUN which is in a NO_HW
state, open() fails and retries. These retries cause delays in
8