Login:
Votes - , Average rating: ( )

User manual HP, model HP Integrity NonStop H-Series

Manafacture: HP
File size: 1010.74 kb
File name:

Language of manual:enda

The document is loading, please wait
The document is loading, please wait


Other manuals for this model:

manual abstract


1806
Duplicate memory slot for domain: domain, Dmn#: domain number
Cause. ASAPX detected duplicate Domain table entries while restarting domain for
the same memory slot location. Only the first domain is restarted; all others cause this
error message to be generated. This should not occur, although it might after CPU
failures and subsequent loss of shared memory.
Effect. ASAPX could not restart a domain because its domain record referred to a
domain number that is already in use. The domain is not restarted.
Recovery. If the domain ASAPX restarted is not the correct one, manually remove the
domain using the ASAPX REMOVE command and restart ASAPX.
1807
Domain name error in record: domain, Dmn#: domain number
Cause. The Domain table has been corrupted. ASAPX detected an error in the
domain name field for the specified domain in the Domain table.
Effect. While attempting to reload domains at startup, ASAPX found an error in the
name of a domain. The domain is not restarted.
Recovery. Manually remove the domain in question. If more than one domain has
been corrupted:
1. Make sure that all of the application processes are running and that all of their
domains are registered, or shut down all application processes using ASAPX. If an
application process is left executing, one must be executing in each processor with
at least one registered domain. To verify this, run a FILEINFO command against
the ASAPX swap subvolume or subvolumes. Verify that all shared memory
segment files are open. These files are named Zasapid Cn where asap id is
the ASAP ID from the ASAPCONF file, and n is the CPU number. If one shared
memory segment file is open, they all must be open.
2. Stop ASAP using the ASAP SHUTDOWN command.
3. Enter the ASAPX CLEANUP DOMAINS command to purge the Domain table.
4. Restart ASAP with the ASAP START command. If the application processes
remained executing, ASAPX completely rebuilds the Domain table from shared
memory. If the applications were shut down, the Domain table is rebuilt over time
as they restart and register with ASAPX.
HP NonStop ASAP Messages Manual429917-004
1-68


...

Other models in this manual:
Desktops - HP Integrity NonStop J-Series (1010.74 kb)
Desktops - HP NonStop G-Series (1010.74 kb)
Desktops - HP NonStop L-Series (1010.74 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category