Login:
Sorted: Name ↑   Downloads   Rate   Size ↓  

Ducane Electric Air Conditioning 2SA13B

downloaded: 54File size: 241 kb    Manafacture: Ducane  
Category: Air Conditioner & Split Systems

See limited warranty document for details. Ducane Package Electric Air Conditioning 2SA13B /¡r>: * am PERFORMANCE CERTIFIED Duccme AIR CONDITIONING AND HEATING Model Number Guide SA 13 24 A 2 - R22- -Minor Revision Code Single Package A/C-13-13 SEER Nominah Series -Major Revision Code Voltage ~208-230V/60Hz/1Ph _Nominal Cooling "24 - 24,000 Btuh Physical Model Outside Fan Indoor Blower Wheel dia. X width (in.) Refrigerant Charge (oz.) Weight (lbs.) Diameter (in.) Nominal

Ducane Fits-All 92

downloaded: 55File size: 303 kb    Manafacture: Ducane  
Category: Electric Heaters

VENTING Category IV appliance Can be vented horizontally or vertically using 2” or 3” Schedule 40 PVC, ABS, or CPVC (see installation manual for details) Approved for 2-pipe (direct vent) or single-pipe applications Approved for installations with listed concentric vent kit CONTROLS Direct 115V Hot Surface Ignition system with LED diagnostic for fast, accurate troubleshooting Slow opening valve for quiet, smooth ignition Electronic fan timer control SAFETY CSA certified for US and Canada Safety

Ducane RHP13

downloaded: 121File size: 522 kb    Manafacture: Ducane  
Category: Air Conditioner & Split Systems

diagostics • Defrost control board with field selectable time intervals • High and low refrigerant pressure switches for system protection Installation • Full perimeter base rail system for easy installation • Horizontal or down discharge, duct covers provided • Utility connections on “right side” • Filter channels for 1" filter field provided Warranty • 10 year limited parts and compressor warranty. See limited warranty document for details. Model Number Guide RHP 13 A 36 P-1 A Residential Pack

Ducane RGE13

downloaded: 101File size: 585 kb    Manafacture: Ducane  
Category: Air Conditioner & Split Systems

diagnostics • Direct spark ignition Installation • Full perimeter base rail system for easy installation • Horizontal or down discharge, duct covers provided • Utility connections on “right side” • Filter channels for 1" filter field provided Warranty • 10 year limited parts and compressor warranty/lifetime heat exchanger warranty available. See limited warranty document for details. Model Number Guide RGE 13 A 36 075 L P- 1 A Residential Packaged Gas / Electric SEER 13 Series A - Service Level

Ducane B

downloaded: 64File size: 760 kb    Manafacture: Ducane  
Category: Air Conditioner & Split Systems

This feature is standard on all Allied Air Enterprises furnace and air handler products. 2AC14 Split System Air Conditioner 1 Cooling Performance with Air Handlers & Furnaces 36, 42, 48, 60 4 Outdoor Model Indoor 1 i/lodel Variable Speed Furnace SEER EER Rated ARI Capacity1 Rated Sensible Capacity CFM Refrigerant Connection Refrigerant Line Size Indoor Metering Device Piston or Field Installed TXV Factory Installed TXV Outdoor Indoor n io ct u S id ui Req'd Indoor2 Orifice O

Ducane 2AC14

downloaded: 16File size: 760 kb    Manafacture: Ducane  
Category: Air Conditioner & Split Systems

This feature is standard on all Allied Air Enterprises furnace and air handler products. 1 4 2AC14 Split System Air Conditioner Cooling Performance with Extended Ratings Outdoor Model Indoor Model Indoor Temp DB/WB °F Outdoor Temp - DB°F 65 82 95 105 115 Piston or Field Installed TXV Factory Installed TXV Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW 2AC14**18P E(C,H,M,U) 1P23(A,B)+TXV E(C,H,M,U) 2T23(A,B) 1P23(A,B)+TXV 85/

Ducane LC

downloaded: 20File size: 760 kb    Manafacture: Ducane  
Category: Air Conditioner & Split Systems

D2AC14B,L,BC,LC-100 (10/08) ©2008 Allied Air Enterprises Inc., a Lennox International Inc. Company Printed in the U.S.A. D&S

Ducane BC

downloaded: 29File size: 760 kb    Manafacture: Ducane  
Category: Air Conditioner & Split Systems

See limited warranty document for details. 4 2AC14 Split System Air Conditioner Model Number Guide AC 14 36 A Refrigerant - 2 = R22 - AC = Split Condensing Unit " 14 - 14 SEER Nominal - B = Wire Guard L = Louvered -BC = Wire Guard + 76dBA LC = Louvered + 76dBA Nominal Capacity 36 - 36,000 Btuh 2 B P 1 Electrical and Physical Data Model Voltage/ Hz/ Phase Voltage Range Min. Circuit Amp. Maximum Over Current Device (amps) Compressor Fan Motor Refrig. Charge (oz.): Weight (lbs.

Ducane L

downloaded: 18File size: 760 kb    Manafacture: Ducane  
Category: Air Conditioner & Split Systems

This feature is standard on all Allied Air Enterprises furnace and air handler products. 1 4 2AC14 Split System Air Conditioner Cooling Performance with Extended Ratings Outdoor Model Indoor Model Indoor Temp DB/WB °F Outdoor Temp - DB°F 65 82 95 105 115 Piston or Field Installed TXV Factory Installed TXV Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW 2AC14**18P E(C,H,M,U) 1P23(A,B)+TXV E(C,H,M,U) 2T23(A,B) 1P23(A,B)+TXV 85/

Ducane 2020802

downloaded: 0File size: 4 mb    Manafacture: Ducane  
Category: Convection Ovens

WARNING: Never leave a grill unattended to guard against possible grease fires getting out of control. Grease fires can be severe and cause grill damage, property damage and bodily harm. Open or Close Lid for Grilling Cooking with the lid open or closed is a matter of personal preference. Cooking with the lid closed is recommended if you enjoy cooking at maximum “searing” temperatures. This method will also speed the cooking process, and will give you a more robust, smoky, outdoor flavor. If yo





Category