Distribute the pieces over the surface of the burner, as shown in Figures 9 and 10. Do not use more than is necessary. Position the embers on the small holes of the ember bed area. Note: Make sure the glowing ember material does NOT cover the main burner slots. 5. Install the Logs. The logs have locating notches or slots to help ensurethattheyareproperly positioned. The top logs that rest on lower logs, do so over notches, indents or nubs. Proper log placement is critical to prevent sooting. Log
Min. (25 mm) DrywallBracket/Spacer Top Spacers Step 12. ATTACHING SAFETY-IN-OPERATION WARNINGS Step 12. ATTACHING SAFETY-IN-OPERATION WARNINGS ATTACHING SAFETY-IN-OPERATION WARNINGS It is required that the safety instruction labels furnished with the fireplace be affixed to the operation and control point of the fireplace. A safety instruction label must be affixed to the wall switch plate where the fireplace is turned on and off (See Figure A) or wall thermostat (See Figure B) and if used on th
Gas conversion kits are available to adapt your appliance from the use of one type of gas to the use of another. These kits contain all the necessary components needed to complete the task including labeling that must be affixed to ensure safe operation. Kit part numbers are listed here and the following steps detail the conversion procedure. Refer to the instructions provided with the conversion kit when performing any gas conversion. Gas Conversion Kits WARNING This conversion kit shall be ins
750,109M Ref. 750,055M 14 Ref. 750,246M 34 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Item Cat. No. Model Description 18 H1969 SF4.5HT-2 Horizontal Square Termination (without flex) 18 77L87 SFKIT12S Flex Square Term. (with 12 inch [305 mm] * compressed flex) 18 77L88 SFKIT18S Flex Square Term. (with 18 inch [457 mm] * compressed flex) 18 77L89 SFKIT24S Flex Square Term. (with 24 inch [610 mm] * compressed flex) 18 77L90 SFKIT36S Flex Square Term. (with 36 inch [914 mm] * compressed flex)
5 LOCATION In selecting the location, the aesthetic and functional use of the appliance are primary concerns. However, vent system routing to the exterior and access to the fuel supply are also important. Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies (Figure 3). En raison des temperatures elevees, l’appareil devrait etre installe dans un endroit ou il y a peu de circulation et loin du mobilier et des tentures (Figure 3). The locati
Both of these horizontal vent systems terminate through an outside wall. Building Codes limit or prohibit terminating in specific areas. See Figures 5 and 6 on Pages 6 and 7 for location guidelines. Secure Vent SV4.5 direct-vent system components are unitized concentric pipe components featuring positive twist lock connection, (refer to Figure 21 on Page 14). All of the appliances covered in this document are fitted with collars having locking inclined channels. The dimpled end of the vent compo
Pegue la etiqueta en la superficie del transmisor (Figura C). Seleccione el idioma que mas se habla en la casa. 3. Si no puede encontrar las etiquetas, sirvase llamar a Lennox Hearth Products o al distribuidor de Lennox Hearth Products mas cercano para recibir etiquetas de instrucciones de seguridad adicionales gratuitas. Juego de etiquetas de repuesto - N. de cat. H8024 LENNOX HEARTH PRODUCTS 1-800-9-LENNOX Nota: La etiqueta en ingles es transparente con texto rojo. Las etiquetas en frances y e
The nailing flange itself can directly contact framing. Floor Nailing Tabs - Secure the fireplace to the floor as shown in Figure 10. Figure 10 - Nailing Flanges Remove these screws and use them when installing nailing flanges. Nailing Flanges Turn nailing tabs down and secure to floor with 8d nails or other appropriate fasteners on both sides of appliance which do not have viewing glass panels. SDVST Shown (SDVPF - No nailing flanges on end with glass panel) Detailed Installation Steps The appl
Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combustion, soot ing, and poor flame quality. REFERENCE Firebox Accessories / Parts Cat. No. Model No. Description 88L5 FGE Bag of Glowing Embers (1 oz. rockwool) 80L4 FDVS Bag of Decorative Volcanic Stone Table 8 Glowing Embers Bag of Glowing Embers (rockwool) Separate into Quarter Size (separate) Pieces WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencomplet
Installation must conform to local codes. In the absence of local codes, installation must complywiththecurrentNationalFuelGasCode, ANSIZ223.1 (NFPA 54). (InCanada,thecurrent CAN/CGA B149 installation code). Electrical wiring must comply with local codes. In the absence of local codes, installation must be in accordance with the National Electrical Code, NFPA70-(latestedition).(InCanada,thecurrent CSA C22.1 Canadian Electric Code). GENERAL INFORMATION Note: Installation and repair should be perf