Login:
Votes - 4, Average rating: 4.3 ( )

User manual Superior, model SSDVST-CNE-B

Manafacture: Superior
File size: 4.94 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


750,109M Ref. 750,055M 14 Ref. 750,246M 34 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Item Cat. No. Model Description 18 H1969 SF4.5HT-2 Horizontal Square Termination (without flex) 18 77L87 SFKIT12S Flex Square Term. (with 12 inch [305 mm] * compressed flex) 18 77L88 SFKIT18S Flex Square Term. (with 18 inch [457 mm] * compressed flex) 18 77L89 SFKIT24S Flex Square Term. (with 24 inch [610 mm] * compressed flex) 18 77L90 SFKIT36S Flex Square Term. (with 36 inch [914 mm] * compressed flex) 18 77L91 SFKIT48S Flex Square Term. (with 48 inch [1219 mm] * compressed flex) 19 56L74 SFVT30 Vertical Termination for flex (flat to 6/12) with flex adapter, section of rigid vent, roof support collar assembly, roof flashing and storm collar. 19 56L75 SFVT45 Vertical Termination for flex (6/12 to 12/12) with flex adapter, section of rigid vent, roof support collar assembly, roof flashing and storm collar. *20 60L10 SF-18 18 ft. (5.49 m) * compressed flex *20 98K03 SF-12 12 ft. (3.66 m) * compressed flex 22 10K81 SFMP Mill-Pac, Black, High Temperature Sealant 22 89L40 SFMP-12 Mill-Pac, Black, High Temperature Sealant - Bulk 12 pack 23 91L66 SF-GC4-6 Gear Clamp 4.5 in. (114 mm) for flex (6 pieces) 23 91L67 SF-GC7-6 Gear Clamp 7.5 in. (190.5 mm) for flex (6 pieces) 25 H1988 CTSA-33 Chase Top Shroud Kit, Arch Top 3 X 3 26 H1985 CTSO-33 Chase Top Shroud Kit, Open Top 3 X 3 26 H1987 CTSO-44 Chase Top Shroud Kit, Open Top 4 X 4 26 H1986 CTSO-46 Chase Top Shroud Kit, Open Top 4 X 6 8 H2248 SF4.5HF Firestop / Spacer - Horizontal (flex) (3-1-1 spacing), 10 Pack 8 H2249 SF4.5VF Firestop / Spacer - Vertical (1-1-1 spacing), 10 Pack 22 23 19 Sealant 20 18 Open Top Shroud Kits Inches (millimeters) Model A B C D *E CTSO-33 37-5/8 (955) 37-5/8 (955) 7-1/2 (191) 24-1/2 (622) 3 (76) CTSO-44 48-5/8 (1235) 48-5/8 (1235) 7-1/2 (191) 24-1/2 (622) 3 (76) CTSO-46 48-5/8 (1235) 73 1/4 (1860) 7-1/2 (191) 24-1/2 (622) 3 (76) E C E CTSO-33/44 Shrouds for Single terminations CTSO-46 Shroud for double terminations 1 2 typ. typ. 1 typ. 2a 2a 2a 2a 2b 2b 2b C D A B Closed Top Shroud Termination Kits Inches (millimeters) Model A B C D CTSA-33 34" (864) 5" (127) 34" (864) 34" (864) B A D C A B D Ref. Form #750,193M Ref. Form #750,194M * All compressed flex vents can be expanded up to two times. 26 25 35 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Natural Gas to Propane Gas Conversion Kits Fireplace Type Cat. No. (model) Millivolt 85L65 FGCK-DMOMNP Electronic 85L79 FGCK-DMOENP Propane Gas to Natural Gas Conversion Kits Fireplace Type Cat. No. (model) Millivolt 85L72 FGCK-DMOMPN Electronic 85L86 FGCK-DMOEPN Installation Instructions Step 1. TURN OFF THE GAS SUPPLY TO THE APPLIANCE and disconnect power supply at the circuit breaker. Ensure appliance is cold. CAUTION: THE GAS SUPPLY SHALL BE SHUT OFF PRIOR TO DISCONNECTING THE ELECTRICAL POWER, BEFORE PROCEEDING WITH THE CONVERSION. ATTENTION : AVANT D’EFFECTUER LA CONVERSION, COUPEZ D’ABORD L’ALIMENTATION EN GAZ, ENSUITE, COUPEZ L’ALIMENTATION ELECTRIQUE. Step 2. Remove the front glass door assembly from the appliance (see Removing Glass Enclosure Panels on Page 30). Remove the control compartment door (see Control Compartment Door Removal on Page 27). Step 3. Carefully remove the logs. Exercise care so as not to break the logs. Step 4. Refer to Figure 60. Remove the front burner and then the rear burner. FRONT OF FIREPLACE REAR BURNER FRONT BURNER VENTURI TUBE ARM VENTURI TUBE ARM AIR SHUTTER ADJUSTMENT LEVER FIREBOX SUBFLOOR NOTE: REMOVE FRONT BURNER FIRST, THEN REAR BURNER. Figure 60 Millivolt Appliances Step 5. - SIT Systems - Refer to Figure 61 on Page 36 and the instructions provided with the kit. Using a Torx T20 (with 1/4" shank and center hole), tool or standard flat screwdriver remove and discard the three pressure regulator mounting screws. Remove the pressure regulator, spring, poppet, diaphragm and bushing. Discard all removed components. Ensure the rubber gasket installed on the back of the replacement pressure regulator is properly positioned and install the new pressure regulator using the new screws supplied with the kit. Tighten screws to 25 In. lb. torque. In Canada: The conversion shall be car - ried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the CAN/CSA-B149.1 Installation code. La conversion devra etre effectu ee conformement aux recommandations des autorites provinciales ayant juridiction et conform ement aux exigences du code d'installation CAN/CSA-B149.1. Gas conversion kits are available to adapt your appliance from the use of one type of gas to the use of another. These kits contain all the necessary components needed to complete the task including labeling that must be affixed to ensure safe operation. Kit part numbers are listed here and the following steps detail the conversion procedure. Refer to the instructions provided with the conversion kit when performing any gas conversio...

Other models in this manual:
Fireplaces - SSDVPF-CNE-B (4.94 mb)
Fireplaces - SSDVPF-CNE-B (4.94 mb)
Fireplaces - SSDVPF-CNE-B (4.94 mb)
Fireplaces - SSDVPF-CNE-B (4.94 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category