The scope is turned off immediately after releasing remote control button. low bATTERy InDIcAToR When red LED on left side of the field of view starts blinking it is time to change your battery. RETIclE Your scope has an Electronic reticle with two color and 5 degrees of brightnes of illumination for each color. The knob of brightnes ajustment reticle and color select is located on the top of the boby of the scope. On the knob there are marking with color of illumination of reticle. should be us
It is unlawful and strictly prohibited to export, or attempt to export or otherwise transfer or sell any hardware or technical data or furnish any service to any foreign person, whether abroad or in the United States, for which a license or written approval of the U.S. Government is required, without first obtaining the required license or written approval from the Department of the U.S. Government having jurisdiction. Diversion contrary to U.S. law is prohibited. AmERIcAn TEchnologIEs nETwoRk c
ATN Corp. assumes no responsibility or liability for any errors or inaccuracies that may appear in this book. ©2002 ATN Corp. All right reserved. Master power (ON/OFF) switch 100m Infra-red illuminator Proximity sensor Manual focus lens; 5’ to infinity Diopter Control panel Fixator screws Aries MK6600/7700/8700 Elevation Batterycompartment Windage Remote control panel Mounting bracket (mounts to standard U.S. 7/8” weaver rail) Aries MK6650/7750/8750 Remote control Reticle Pattern Selector button
Adjust as necessary. 3. Tighten the horizontal fixing screws. NOTE: Receptor attachment screws may need to be tightened after continuous shooting. Diopter Front lens Insert large allen wrench here to lock/unlock and to remove lens Fixator screws WINDAGE AND ELEVATION To adjust vertical and horizontal positions for the Aries MK6600/6650/7700/7750/8700/8750 turn the elevation and windage adjustment mechanisms. Each click equals to 1/8 inch at 100 yards. Do not use force having reached the maximum
Each click equals to 1/8 inch at 100 yards. Do not use force having reached the maximum of rotation. USING THE REMOTE CONTROL Below the control box you can find the panel with two screws to fix Aries MK6600/6650/7700/7750/8700/ 8750. To plug in the remote control, remove the screws and the small panel to disclose the inlet. The three remote control buttons’ function similarly to control box buttons. Once the remote control is plugged in you may use both panels to adjust the scope. The remote con
Be careful not to scratch or smudge any of these surfaces. When using compressed air to blow dust away, make sure to avoid inverting the can while spraying. This can cause frozen propellant to exit the can, which can cause serious problems with the glass and phosphor screen. WARNINGS AND CAUTIONS • Always remember to turn off the Aries MK6600/6650/7700/7750/8700/8750 when it is not in use. If you do not plan on using your aries scope for a period of more than 10 days, you should remove the batte
To disable the proximity sensor press SL and “+” simultaneously. In order to turn the proximity sensor back on, press SL and “+” simultaneously again. NOTE: The scope is capable of running in SLEEP mode for more than 10 (ten) days and is ready for use at any moment. Remember, you don’t have to turn the unit off while you are using it (“Smart” sight remembers all the settings). Use the master ON/OFF switch only to store the scope. PROXIMITY SENSOR If you turn the proximity sensor on it will activ
©2002 ATN Corp. All right reserved. Master power (ON/OFF) switch 100m Infra-red illuminator Proximity sensor Manual focus lens; 5’ to infinity Diopter Control panel Fixator screws Aries MK6600/7700/8700 Elevation Batterycompartment Windage Remote control panel Mounting bracket (mounts to standard U.S. 7/8” weaver rail) Aries MK6650/7750/8750 Remote control Reticle Pattern Selector button APPLICATION The Aries MK6600/6650/7700/7750/8700/8750 night vision weapon scope is a complex computerized sys
It also will act as a daylight filter, allowing you to test the scope in daylight or other bright light situations. The pinhole in the center of the protective cover allows the user to check the operation ability of the device in daylight conditions. NOTE: Do not test the scope in daylight conditions even with the daylight filter/lens cap on for more than ten (10) minutes. operATion • Take the monocular out of the case. • Install the battery into the housing with the polarity order as shown on t
This is achieved by combining an advanced image intensification system with a thermal imaging system. The combination of the channels allows the user to take full advantage of both technologies by dichoptically creating a “Fused” image for enhanced night vision observation. The results are a fused image that allows you the benefits and capabilities of both technologies. You will be able to detect both the Image Intensified Night Vision scene and the Thermal Imaging scene so you will not miss a