downloaded: 8   File size: 2 mb   Manafacture: Honda Power Equipment  
Category: Water and Air Pumps
@name

At maximum throttle position, the pump will deliver the highest output volume. Moving the throttle lever toward the idle position will decrease the output volume of the pump. Recoil Starter Grip Pulling the starter grip operates the recoil starter to crank the engine for starting. MAXIMUM THROTTLE 10 CONTROLS & FEATURES FEATURES Oil Alert® System The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the

downloaded: 10   File size: 1 mb   Manafacture: Honda Power Equipment  
Category: Water and Air Pumps
@name

This will close the valves, so moisture cannot enter the engine cylinder. Return the starter rope gently. STORAGE PRECAUTIONS If your pump will be stored with gasoline in the fuel tank and carburetor, it is important to reduce the hazard of gasoline vapor ignition. Select a well-ventilated storage area away from any appliance that operates with a flame, such as a furnace, water heater, or clothes dryer. Also avoid any area with a spark-producing electric motor, or where power tools are operate

downloaded: 7   File size: 722 kb   Manafacture: Honda Power Equipment  
Category: Water and Air Pumps
@name

Inspect or service as scheduled in the table below. Ollllilll Shut off the BfiCjine before performing any maintenance, if the engine must be run, make sure the ares is wei5 ventilated. The exhaust contains poisonous carbon monoxide yas CAUTION: • Pump clean, fresh water through the pump immediately after use to remove sediment and prevent corrosion. • Use only genuine Honda parts or their equivalent for maintenance or repair. Replacement parts which are not of equivalent quality may damage t

downloaded: 10   File size: 1 mb   Manafacture: Honda Power Equipment  
Category: Water and Air Pumps
@name

After drying, fill with engine oil up to the specified level. * Clean more frequently if pump is operated in a dusty area. ELEMENT WARNING ★ Never use gasoline or low flash point solvents for cleaning the air cleaner element. A fire or explosion could result. EVERY I 00 HOURS CHANGE ENGINE OIL CLEAN FUEL FILTER CLEAN SPARK PLUG AND CHECK GAP O * Wash removed parts in high flash point solvent, dry them thoroughly and install securely. Turn the fuel valve ON and check for leaks. CHECK FU

downloaded: 39   File size: 722 kb   Manafacture: Honda Power Equipment  
Category: Water and Air Pumps
@name

TRASH PUMP WT20X*WT30X OWNER'S MANUAL Thank you for purchasing a Honda trash pump. This manual covers the operation and maintenance of WT20X and WT30X trash pumps. Ail information in this publication is based on the latest product information at the time of printing. The illustrations in this manual are based on the WT30X pump. Honda Motor Co., Ltd. reserves the right to make changes at any time without notice and without incurring any obligation. No part of this publication may be reprod

downloaded: 6   File size: 1 mb   Manafacture: Honda Power Equipment  
Category: Water and Air Pumps
@name

о m ALL INFORMATION. ILLUSTRATIONS, DIRECTIONS AND SPECIFICATIONS INCLUDED IN THIS PUBLICATION ARE BASED ON THE LATEST PRODUCT INFORMATION AVAILABLE AT THE TIME OF APPROVAL FOR PRINTING. HONDA MOTOR CO., LTD RESERVES THE RIGHT TO MAKE CHANGES AT ANY TIME WITHOUT NOTICE AND WITHOUT INCURRING ANY OBLIGA TION WHATEVER. NO PART OF THIS PUBLICATION MAY BE REPRODUCED WITHOUT WRITTEN PERMISSION. OWNER’S MANUAL © HONDA MOTOR CO., LTD. 1982 m FOR SAFE OPERATION 'IK'WARNING • To prevent fire haza

downloaded: 6   File size: 871 kb   Manafacture: Honda Power Equipment  
Category: Water and Air Pumps
@name

Constant repetition of this action will shorten pump service life. Do not start the pump again in such a situation until after the motor has completely cooled. Technical Specifications Model WSP33AA WSP53AA WSP73AA Performance: ISO 2548 Standard Optional Discharge Size 1/3 HP – 11/4 inch 1/2 HP and 3/4 HP – 11/2 inch Range of Performance Capacity: up to 74 GPM Head: up to 54 feet Limitation Maximum Water Temperature 122°F/50°C Solids 3/8'' Spherical (2% by concentration) Speed 3600 RPM Materials

downloaded: 9   File size: 871 kb   Manafacture: Honda Power Equipment  
Category: Water and Air Pumps
@name

Outdoor installations should be at a sufficient depth to ensure protection from freezing. Maintenance Tips • Every three or four months: 1) Clean the pump screen or inlet opening. If your sump collects the discharge from an automatic washing machine, cleaning will be required more often. (Before removing the pump be sure to disconnect the unit from electrical power; and reconnect after completion of cleaning); 2) Pour enough water into the sump to cycle the pump and assure its proper functioning

downloaded: 9   File size: 412 kb   Manafacture: Honda Power Equipment  
Category: Water and Air Pumps
@name

If the malfunction of the pump is not among those included in the trou- bleshooting table (chapter 14. I), contact the nearest appointed dealer. This publication contains all the necessary information and instructions for use and maintenance of your submersible sewage pump. Follow the advice given to obtain optimum performance and correct opera- tion of the pump. For any other information you may require, please contact the nearest appointed distributor. IT IS STRICTLY FORBIDDEN TO REPRODUCE THE

downloaded: 4   File size: 871 kb   Manafacture: Honda Power Equipment  
Category: Water and Air Pumps
@name

– All Rights Reserved Thank you for purchasing this Honda Stainless Steel Sump Pump. We hope you are pleased with your purchase and that our pumps will provide you with long service life and exceptional performance. Thank you for purchasing this Honda Stainless Steel Sump Pump. We hope you are pleased with your purchase and that our pumps will provide you with long service life and exceptional performance. Please contact your supplier (supplying dealer or contractor) if service is necessary or i