downloaded: 3   File size: 947 kb   Manafacture: Haier  
Category: Air Conditioner & Split Systems
@name

F, Outdoor 95. F (2) Indoor 70/58. F, Outdoor 47. F Multi-Zone System Cooling Capacity (Btuh) SEER Heating Capacity (Btuh) (6) HSPF Volts/HZ/Phase Cond Fan Mtr Compressor Circuits 1 & 2 Indoor Fans Total Amps MCA HACR BRKR Min Volt Nominal (5) Sensible AMPS HP RLA LRA AMPS HP HMCW18000 (1) 18,000 12,600 10.9 --208/230/60/1 0.72 0.2 4.45 26 0.22 0.06 10.1 11.1 15 197 HMHW18000 (2) 17,400 11,700 10.0 17,700 6.8 208/230/60/1 0.72 0.2 4.45 26 0.22 0.06 10.1 11.1 15 197 HMCW24000 (3) 24,000 15,500 10

downloaded: 4   File size: 947 kb   Manafacture: Haier  
Category: Air Conditioner & Split Systems
@name

• Select HEAT, DRY, Cool or CIRCULATE mode as you wish. OPERATION (Continued) OPERATION (Continued) HEAT MODE (Except Cool model) • In case of Cool and Dry mode, water may drop according to the contaminating status of air filter. In this case, please clean or replace the air filter with a new one. ! CAUTION ! • ..........Heating Capability: ~ This is a Heat pump type air conditioner which is heating the room by absorbing the outside air to the room. Therefore, as outside temperature drops, heati

downloaded: 5   File size: 947 kb   Manafacture: Haier  
Category: Air Conditioner & Split Systems
@name

IMPORTANT: Always mount the installation plate horizontally by aligning the marking line with the thread or using a level. 2. Mount the installation plate horizontally and securely on structural members (studs, etc.) in the wall with four (4) installing screws. (See Fig. 1) 3. Make a 2 9/16” hole through the wall. Hole should be angled down to the exterior. (See Fig. 2) 4. Use a city grade wall pipe (outer diameter : 2 3/8”) as a Fig. 1 18/24 Btuh 9/12 Btuh 3.43”4.21” 1.18” 5.53” 9.12”10.83” 2’

downloaded: 5   File size: 947 kb   Manafacture: Haier  
Category: Air Conditioner & Split Systems
@name

• On humid days, frost may form on the surface of air conditioner or condensation may occur. HIGH POWER MODE Convenient on a hot day. (During AUTO, HEAT, COOL or DRY mode) Press the HIGH POWER To CANCEL: Press the HIGH POWER but- button. ton once more. The operation is set back to the previous operation mode. HIGH POWER MODE When the HIGH POWER mode button is pressed, heated or cooled air comes into the room at a higher fan speed for 15 minutes. The fan speed changes rhythmically between high an

downloaded: 4   File size: 947 kb   Manafacture: Haier  
Category: Air Conditioner & Split Systems
@name

• Indoor fan motor(s) stop: In the “AUTO”, “DRY” and “HEAT” operation mode, the indoor fan motor(s) will be stopped when the room temperature reaches the set temperature. • The air conditioner(s) do not start or change operation mode immediately: To prevent overloading the compressors, the air conditioner(s) will not start for approx. 3 minutes. • No change on the operation mode by the remote control: The signal of operation mode changing has not reached the indoor unit(s). Press the ON/OFF butt

downloaded: 3   File size: 947 kb   Manafacture: Haier  
Category: Air Conditioner & Split Systems
@name

10 Interconnection cable 3. Connect the indoor pipes and check for gas leaks. (See Fig. 10) After the leak test, wrap the flared joints with insulation and fix it with bands. 4. Remove the spacer from installation plate. Suction pipe Discharge pipe Indoor unit drain hose ECR International Hyundai Ductless Split System12 INSTALLING OF THE OUTDOOR UNIT Cut pipe by rotating the pipe cutter Pipe Turn the handle Clockwise while pushing it against the pipe Pipe cutter knife Yoke Do not damage the insi

downloaded: 5   File size: 947 kb   Manafacture: Haier  
Category: Air Conditioner & Split Systems
@name

• The ONE HOUR TIMER mode has preference over other Timer modes. If pressing the 1HR TIMER button again during the OFF TIMER mode, the unit(s) will stop operating approximately one (1) hour later. EMERGENCY OPERATION When the remote control cannot be used due to dead batteries or out of order, use the Hand Switch Lever. After turning the Hand Switch Lever to OFF “O” position, turn it to ON “I” again. The lamp will light and the unit(s) will start in the Automatic operation mode. 9/12 Btuh 18/24

downloaded: 6   File size: 947 kb   Manafacture: Haier  
Category: Air Conditioner & Split Systems
@name

2.36”) • Height limit: below 25ft. • Maximum tubing length: below 50ft. Tubing length over 25ft. 9/12 Btuh (Single or Multi-Zone) • Charge additional refrigerant amount, Parts of Indoor Unit No. Part Qty 1 Remote Control 1/unit 2 Remote Control Fixture 1/unit 3 Batteries 'LR03' (AAA) 2/unit 4 Manual 1 Parts of Outdoor Unit No. Part Qty 1 9/12 Btuh 4 Rubber Cushion 2 18/24 Btuh 4 Rubber Cushion 3 Drain Pipe 1 DETERMINATION OF INSTALLING POSITION Install the Air Conditioner(s) by taking into accou

downloaded: 7   File size: 947 kb   Manafacture: Haier  
Category: Air Conditioner & Split Systems
@name

Set time AM 10:00 by pressing button. • Time can be adjusted by pressing and holding the button. It can also be adjusted in one minute intervals by single pressing and releasing the button. 2. Set current time by pressing button. NOTE: If current time is not set correctly, the timer will not operate normally. INSTALLING REMOTE CONTROL HOLDER(S) 2 Push 1 Place • Place the bottom of the Remote Control on the hook first and then push it into the holder. NOTE: The transmitting distance may be shorte

downloaded: 4   File size: 947 kb   Manafacture: Haier  
Category: Air Conditioner & Split Systems
@name

• In the event of lightning, stop the air conditioner(s) and disconnect the power source. • Do not touch the heat exchanger, pipes and valves on the outdoor unit during cooling cycle. You may get burned. • The fuse or the circuit breaker must comply with national and local codes. • Do not modify the system(s). It may increase the risk of fire. • Never expose infants, handicapped persons, or seniors directly to the airflow. Adjust the room temperature and the airflow direction. • Make sure that t