Providing you with new safety and reliability, the upgraded Stinger™ is capable of recovering all commonly used* CFC, HFC and HCFC refrigerants, including R-410A (Puron™). The unit is easy to operate and is ideal for evacuating both residential and light commercial systems. A simple purge system prevents cross contamination of refrigerants without changing hose. *Not for use with R-11, R-113 or R-123 BACHARACHISAU.S.MANUFACTURER2006-3800 Domestic 120V 2006-3801 Domestic 120V w/80% 2006-3807 Euro
Instant mount models are designed for Windows 27.5 inch (699mm) to 36 inch (914mm) wide. 3. Mark the center of Window sill with pencil. 4. Insert Screws (Type A) into the sill bracket. 5. Attach Sill bracket to window sill using two Screws (Type B) by each bracket. The outside edge of window bracket should be 11.8 inch (300mm) from center line. 6. Adjust Screw (Type A) so that Sill Bracket have a slight tilt by using carpenter's level meter. Window Shutter (2 pieces) Window kit FrameLeft side (1
of the right side. There are two kinds of method to install the drain cap. The rear side of the unit The first method is that the shape of hole like It is good for the household. The second method is that the shape of hole is like It is good for the shop. • DOOR VENT The door vent for the room air ventilation is lever type. If the door vent lever moves to the left, then close the vent and moves to the rght, then open the vent. Close Vent Open Drain Cap SEAL DRAIN Screw (Type D) Door Vent > 11 CA
2. Avoid the unit being exposed to direct sunlight. Keep direct sunlight from the room. 3. Do not leave doors and windows open. • FAN & COOLING CONTROL The Fan Control Selector Switch has six positions. Choose one of the speed settings by rotating the fan control Selector Switch to the appropriate position. CAUTION When the air conditioner has been performing its cooling operation and is turned “OFF” or set to the ‘FAN” position, wait at least 3 minutes before resetting to the cooling operation.
However, if you still elect to use an extension cord, it is absolutely necessary that it will be a UL listed 3-wire grounding type appliance extension cord rated has a 3-blade grounding plug and a 3-slot receptacle that will plug into the appliance. The marked rating of the extension cord should be 125V/13A minimum for DWC-100C, DWC-100CS, DWC-121C, DWC-121CS and 250V/10A minimum for DWA-122C, DWA-122CS, DWA-150C, DWA-150CS, DWA-151C, DWA-151CS. WARNING : To avoid death, personal injury or prope
CARE AND MAINTENANCE ..............................................................................12 • AIR FILTER • CLEANING THE AIR CONDITIONER 7. ELECTRICAL REQUIREMENTS .........................................................................13 • ELECTRICAL GROUNDING INSTRUCTIONS. • USE OF EXTENSION CORDS 8. BEFORE CALLING FOR SERVICE......................................................................14 GENERAL SPECIFICATIONS MODEL ITEM DWC-051C DWC-072C DWC-073C DWC-092C DWC-094C POWER SO
A tight seal is essential. Read through the Use & Care manual to become familiar with the operation of your room air conditioner. CAUTION Do not lift window sash without holding the unit. The window sash helps keep the unit in the window. Exercise caution when opening the window. Failure to do so many result in personal injury and/or property damage. • Step 7 - Install Unit and assemble Front Grille 1. Push the unit into the installed Chassis. 2. Fasten Base Pan and Chassis with screws to side h
If a two-prong wall receptacle is encountered, the customer is required to contact a qualified electrician and have the two-prong wall receptacle replaced with a properly grounded three-prong wall receptacle in accordance with the National Electrical Code. WARNING : To avoid death, personal injury or properly damage due to electrical shock, this unit must be grounded. Do not under any circumstances cut or remove the round grounding prong from the plug. Do not use a two prong adapter. • USE OF EX
The complete electrical rating of your air conditioner is stated on the name plate located at the unit’s side. Be sure the plug receptacle is close enough for the power cord to reach it. WARNING : An extension cord should not be used with your air conditioner! To minimize shock and fire hazards, proper grounding is important. For your safety and protection,this air conditioner is equipped with a special three-prong grounding plug on the service cord. WARNING : Do not, under any circumstances, cu
A tight seal is essential. Read through the Use & Care manual to become familiar with the operation of your room air conditioner. CAUTION Do not lift window sash without holding the unit. The window sash helps keep the unit in the window. Exercise caution when opening the window. Failure to do so many result in personal injury and/or property damage. • Step 7 - Install Unit and assemble Front Grille 1. Push the unit into the installed Chassis. 2. Fasten Base Pan and Chassis with screws to side h