NOTE: For Method 1, it is not essential to synchronize the furnace blower operation with the unit operation, but we recommend it. CAUTION If using Method 2, make sure the furnace/air handler blower operation is synchronized with the unit operation! See Section 5. - 12 3. INSTALLATION (CONT’D) 3.7 CONNECTING THE DUCTS TO THE UNIT Insulated flexible ducts Use the following procedure for connecting the insulated flexible ducts to the port of the unit (Exhaust air to outsideand Fresh air from outsid
Check if all wires are correctly inserted in their corresponding holes in the terminal block. (A wire is correctly inserted when its orange receptacle is lower than another one without wire. On picture beside, wire A is correctly inserted, but not wire B.) A B VE0106 - 17 4. CONTROLS (CONT’D) 4.2 ELECTRICAL CONNECTION TO OPTIONAL WALL CONTROLS (CONT’D) 4.2.1 ELECTRICAL CONNECTION TO VT4W MAIN WALL CONTROL NO C NC I OC OL Y R G B BGOCG BY VE0100A MAIN WALL CONTROL VT4W REAR VIEW 4.2.2 ELECTRICAL
BROAN-NUTONE LLC 926 West State Street Hartford, WI 53027 (1-800-637-1453) GARANTIA BROAN-NUTONE LLC LIMITADA POR UN ANO Broan-NuTone LLC garantiza al consumidor comprador original de sus productos que dichos productos careceran de defectos en materiales o en mano de obra por un periodo de un ano a partir de la fecha original de compra. NO EXISTEN OTRAS GARANTIAS, NI EXPLICITAS NI IMPLICITAS, INCLUYENDO, PERO NO LIMITADAS A, GARANTIAS IMPLICITAS DE COMERCIALIZACION O APTITUD PARA UN PROPOSITO PA
BROAN-NUTONE LLC SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, yo
The duration of an implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE LLC’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE LLC’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE LLC SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTIO
The heater can be operated using the Broan Model 86 Line- Voltage Thermostat from a wall location or the Broan Model 83 Integral Thermostat installed into heater. Purchase the control separately. The table below lists the ratings for each model. MODELS VOLTS AMPS WATTS BTU/HR 120 8.33/4.16 1000/500 3413/1707 170F 240 4.16 1000 3413 208 3.61 750 2560 120 12.5/6.25 1500/750 5120/2560 174F 240 6.25 1500 5120 208 5.41 1125 3640 178F 240 208 8.33/4.16 7.21/3.61 2000/1000 1500/750 6827/3413 5120/2560
See "OPTIONAL WIRING CONVERSIONS" section on pages 2 and 3 for wattage and voltage conversion instructions. Follow these basic steps when installing this heater: • Remove the housing mask. • Fasten finish assembly inside housing. • Plug assembly in. • Attach grille. WALL STUD POWER CABLE GRILLE HEATER HOUSING DRYWALL INSTALL THE HEATER ASSEMBLY 1. Remove housing mask. Make sure wall has been finished (including paint or wall paper, etc.) Take out and discard the cardboard mask from inside of hou
Such blockage will lower its efficiency and create a possible overheating condition. To clean grille, use a soft cloth which has been moistened with household window cleaner. CAUTION: METALAND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER. FIG. 7 COMPLETE LA INSTALACION 1. Ponga la rejilla. Fije la rejilla al calentador con dos (2) tornillos de la bolsa de piezas. (FIG. 7) 2. Empuje la perilla en el vastago del termostato. 3. Compruebe el funcionamiento Conecte la energia en la entrada de s
FOR SAFETY, THIS PRODUCT MUST BE GROUNDED. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN. 2. WHEN WIRING, SERVICING OR CLEANING THIS UNIT, TURN OFF POWER AND LOCK OUT SERVICE PANEL. FAILURE TO DO SO COULD ALLOW OTHERS OR THERMOSTAT TO TURN ON POWER UNEXPECTEDLY WHICH MAY CAUSE FATAL ELECTRICAL SHOCK. 3. To avoid electrical shock: • DO NOT install unit in a tub or shower enclosure or any location where it may come in contact wit