Heats rooms that were cool with previous furnace. So far we have used less kw of power each month compared to the previous year. ” Bob Williams, VP ofRossoe Energy Systems & Oil Company When you want to experience exceptional comfort, increased efficiency, and quieter operation while still receiving the handcrafted quality and proven warranty of Thermo Pride’s traditional oil furnace, select the Premiere Oil Furnace with the ECM variable-speed blower motor. Since the ECM motor automatically ad
rated input BTU) 63° Rise 1260 1500 1260 1500 69° Rise 1162 1350 1162 1350 75° Rise 1050 1245 1050 1245 83° Rise 938 1125 938 1125 The standard motor size may not support this cfm at high static pressures. * Model numbers end with ‘E' to signify ECM motor. Additional Features - General • Eliminates the need for air temp thermostat to control fan cycling by using time instead. • Selectable blower turn-on and turn-off delays to adjust comfort & efficiency (turn-on: 30, 60, 1
Since 1955, Thermo Pride has backed our heat exchangers with the industry’s only transferable Limited Lifetime Warranty. We also offer a full five-year parts warranty at no additional cost. Together, these make up Thermo Pride’s unique “Peace of Mind” warranty…our assurance to you that, when you buy Thermo Pride, you buy the best. Comfort Comfort is the purpose behind any heating system. “Temperature rise” makes the difference between feeling warm, comfortable air from the registers in your home
c WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE, OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, OR SERVICE AGENCY. PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE PERFORMING ANY SERVICE OR MAINTENANCE. THESE INSTRUCTIONS MUST BE LEFT WITH THE USER AND SHOULD BE RETAINED FOR FUTURE REFERENCE BY QUALIFIED SERVICE PERSONNEL. THERMO PRODUCTS, LLC. PO B
: Shut off the power to the furnace before removing blower compartment door to avoid injury from moving parts. : This furnace is not to be used for temporary heating of buildings or structures under construction. : Call a qualified heating contractor to report suspected deficiencies (Do not attempt to make repairs yourself!) All installations and services must be performed by qualified service personnel. 5 II. GENERAL INSTRUCTIONS 1. : Property damage, personal injury, or loss of life could resu
: If you suspect there is a problem with the furnace, its venting system or any other related problem, immediately contact a qualified service agency. 11. Your furnace should be described by the model number and serial number when contacting a qualified heating contractor. This important information is located on the rating plate behind the front door. 12. Should this unit be installed in an attic or other insulated area or if the area is insulated after the furnace is installed, the furnace mus
7. No attempt should be made to restart the unit in the event that gas to the main burner has been shut off. Contact a qualified heating contractor before restarting the furnace. All installations and services must be performed by qualified service personnel. 8. The furnace should be inspected annually by a qualified heating contractor. 9. : Do not use this furnace if any part has been under water. Immediately call a qualified heating contractor to inspect the furnace and to replace any part of
10. Should overheating occur or the gas supply fail to shut off, shut off the manual gas valve to the furnace before shutting off the electrical supply. : If you suspect there is a problem with the furnace, its venting system or any other related problem, immediately contact a qualified service agency. 11. Your furnace should be described by the model number and serial number when contacting a qualified heating contractor. This important information is located on the rating plate behind the fron
7. No attempt should be made to restart the unit in the event that gas to the main burner has been shut off. Contact a qualified heating contractor before restarting the furnace. All installations and services must be performed by qualified service personnel. 8. The furnace should be inspected annually by a qualified heating contractor. 9. : Do not use this furnace if any part has been under water. Immediately call a qualified heating contractor to inspect the furnace and to replace any part of
7 Figure 3 All installations and services must be performed by qualified service personnel. 8 3. : To avoid injury from moving parts, shut off the power to the furnace before removing blower compartment door. 4. : Keep furnace free and clear of combustible materials, gasoline, and other flammable liquids and vapors. 5. The furnace needs air for combustion and ventilation for safe and proper operation. IMPORTANT: Do not block or obstruct air openings on the furnace, air openings communicating wit