New Buck Corporation 81

downloaded: 5File size: 502 kb    Manafacture: New Buck Corporation  
Category: Fireplaces

(A small weight on a string will serve as a plumb bob.) Mark the ceiling where the string is suspended to locate the center of the chimney. 2. After locating the center of the hole, install the ceiling support box, chimney, flashing and rain cap per the chimney manufacturer's instructions. 3. Now connect the stove and ceiling support box using #24 ga. minimum blued or black steel connector pipe. (DO NOT USE GALVANIZED PIPE.) Connect each section so the crimped end faces downward, and secure ea

New Buck Corporation 85

downloaded: 9File size: 574 kb    Manafacture: New Buck Corporation  
Category: Fireplaces

Push up until the face of the outside air duct contacts the underside of the floor of the mobile home. For certain floor thickness, you may have to shorten the length of the outside air duct. 15. Secure the outside air duct to the floor using the four (4) #10 x 1" screws provided. See Figure 12. 26 RAIN CAP RAIN CAP Ceiling Exit (Using Close Clearance Listed Chimney) 1. Suspend a plumb bob from the ceiling above the unit so that the weight is hanging in the center of the flue exit. ( A sma

New Buck Corporation 18

downloaded: 0File size: 660 kb    Manafacture: New Buck Corporation  
Category: Fireplaces

CONTACT LOCAL BUILDING OR FIRE OFFICIALS CONCERNING RESTRICTIONS AND INSTALLATION INSPECTIONS IN YOUR AREA. MANUFACTURED BY NEW BUCK CORPORATION - SPRUCE PINE, NC 28777 THIS PRODUCT IS LISTED BY WARNOCK-HERSEY INTERNATIONAL, INC. TO THE UL STANDARD NO. 1482. REVISED AUGUST 2001 TABLE OF CONTENTS Important Instructions............................................................................................................…..3 SECTION I: Introduction.............................................

New Buck Corporation DV23ZC

downloaded: 12File size: 693 kb    Manafacture: New Buck Corporation  
Category: Fireplaces

-WHAT TO DO IF YOU SMELL GAS * Do not try to light any appliance. * Do not touch any electrical switch; do not use any phone in your building. * Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. * If you cannot reach the gas supplier, call the fire department. -Installation and service must be performed by a qualified installer, service agency, or the gas supplier. -Save this manual for future reference. New Buck Corporation Revised Aug/2008 P.O.

New Buck Corporation CR8T

downloaded: 2File size: 799 kb    Manafacture: New Buck Corporation  
Category: Fireplaces

-WHAT TO DO IF YOU SMELL GAS *Do not try to light any appliance. *Do not touch any electrical switch; do not use any phone in your building. *Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. *If you cannot reach the gas supplier, call the fire department. -Installation and service must be performed by a qualified installer, service agency or the gas supplier. -Save this manual for future reference. This is an unvented and vented gas-fired heater

New Buck Corporation 74

downloaded: 0File size: 931 kb    Manafacture: New Buck Corporation  
Category: Fireplaces

CONTACT LOCAL BUILDING OR FIRE OFFICIALS CONCERNING RESTRICTIONS AND INSTALLATION INSPECTIONS IN YOUR AREA. TESTED AND LISTED BY: ITS/WARNOCK HERSEY, MIDDLETON, WI MANUFACTURED BY NEW BUCK CORPORATION - SPRUCE PINE, NC 28777 5/2007 BUCKSTOVE BUCKSTOVE TABLE OF CONTENTS Important Instructions......................................................................................................... 2 SECTION I: Introduction ............................................................................

New Buck Corporation 32

downloaded: 5File size: 978 kb    Manafacture: New Buck Corporation  
Category: Fireplaces

More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean. Page 17 GAS PRESSURE CHECK Check the inlet pressure to the burner to ensure that it is shown in the table below. NOTE: The pressure check point is located on the right side of the valve facing burner, for SIT Millivolt, and the left side for SIT Modulating. The appliance and its appl

New Buck Corporation 42ZCBB

downloaded: 13File size: 981 kb    Manafacture: New Buck Corporation  
Category: Fireplaces

CONSUMER: Retain this manual for future reference. New Buck Corporation P.O. Box 69 8000 Hwy. 226 South Spruce Pine, NC 28777 Revised: November 2004 TABLE OF CONTENTS Safety Information and Warnings.......................................................................................3 Installation...........................................................................................................................5 Firebox and Framing Dimensions (ZC) (FF)..............................

New Buck Corporation 384

downloaded: 17File size: 1 mb    Manafacture: New Buck Corporation  
Category: Fireplaces

Fully open the manual shutoff valve. 8. Press in and turn knob on gas control counterclockwise to “PILOT” and continue pressing in the knob for (15) fifteen seconds. 9. With control knob pressed in push down (in) and release the ignitor button (ignitor button is located on the left hand side of the front of the appliance). This will light the pilot. If needed, keep repeating this step until pilot lights. 10. Keep control knob pressed in for (1) one minute after lighting pilot. After (1) minut

New Buck Corporation FP-BR-10-ZC

downloaded: 1File size: 1 mb    Manafacture: New Buck Corporation  
Category: Fireplaces

Seal all joints between the black fireplace face and the wall covering with a heat-resistant material such as rock wool insulation or mortar. Be sure to use high temperature adhesive or mortar when anchoring brick, stone, or tile to the face of the fireplace. CLEARANCES To ensure a safe installation, the following must be carefully observed. 1. Sidewall Clearances: Clearances from the right or left side of the fireplace opening to any adjacent combustible wall should not be less than 7", facing