For applications with a high current pulse (e.g., photoflash) and continuous drain, Duracell offeres high rate 3 and 6-volt lithium batteries. Low power lithium coin cells are also available for use in memory backup applications and small electronic devices. All DURACELL® lithium batteries offer high energy density, excellent rate capability, great low temperature performance(1), and excellent shelf life. DURACELL NOMINAL dimensions(2) NOMINAL NOMINAL CROSS REFERENCE PRODUCT SIZE VOLT
Please refer to the charts and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions. This data is subject to change. Performance information is typical. Contact Duracell for the latest information 6/08
Performance information is typical. Contact Duracell for the latest information 6/08
Please refer to the charts and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions. This data is subject to change. Performance information is typical. Contact Duracell for the latest information 6/08
Please refer to the charts and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions. This data is subject to change. Performance information is typical. Contact Duracell for the latest information 6/08 CM Zn/MnO DURACELL N Alkaline-Manganese Dioxide Battery Size: MN 9100 (LR1) o > o > Typical Discharge Characteristics 100 150 Hours of Service Typical Discharge Characteristics Hours of Service DURACELL* BATTERIE
Power Drain @ Various Cutoff Voltage - Room Temperature Power (W) Duracell 2/3A Typical Performance 35mm Point & Shoot Camera 1.2A, 3 sec on 7sec off, to 1.7V @ 20°C 35mm SLR Photo 1.8A, 3 sec on 7sec off, to 2.0V @ 20°C ANSI Photo 0.9A, 3 sec on 27sec off, to 1.55V @ 20°C 500 1000 2000 2500 1500 Pulse Cycles Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts and discharge data shown for examples of the energy
Power Drain @ Various Cutoff Voltage - Room Temperature 0.1 1 Power (W) Duracell Ultra 245 Typical Performance 35mm Point & Shoot Camera 1.2A, 3 sec on 7sec off, cont. to 3.6 V @ 20°C 35mm SLR Photo 1.8A, 3 sec on 7sec off, cont. to 3.6 V @ 20°C Photo 0.9A, 3 sec on 27sec off, cont. to 3.6 V @ 20°C 0 500 1500 2000 1000 Pulse Cycles * Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts and discharge data shown
Power Drain @ Various Cutoff Voltage - Room Temperature 0.2 Power (W) 1 Duracell Ultra 223 Typical Performance 35mm Point & Shoot Camera 1.2A, 3 sec on 7sec off, cont. to 3.6 V @ 20°C 35mm SLR Photo 1.8A, 3 sec on 7sec off, cont. to 3.6 V @ 20°C Photo 0.9A, 3 sec on 27sec off, cont. to 3.6 V @ 20°C 0 500 1000 Pulse Cycles 1500 2000 * Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts and discharge data shown f
Power Drain @ Various Cutoff Voltage - Room Temperature Power (W) Duracell Ultra 123 Typical Performance 35mm Point & Shoot Camera 1.2A, 3 sec on 7sec off, to 1.7V @ 20°C 35mm SLR Photo 1.8A, 3 sec on 7sec off, to 2.0V @ 20°C ANSI Photo 0.9A, 3 sec on 27sec off, to 1.55V @ 20°C 500 1000 2000 2500 1500 Pulse Cycles Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts and discharge data shown for examples of the e
Range: -20°C to 75°C (-4°F to 167°F) NEDA/ANSI: CR2 IEC: - Delivered Energy vs. Power Drain @ Various Cutoff Voltage - Room Temperature Duracell Ultra CR2 Typical Performance 35mm Point & Shoot Camera 1.2A, 3 sec on 7sec off, cont. to 1.8 V @ 20°C 35mm SLR Photo 1.8A, 3 sec on 7sec off, cont. to 1.8 V @ 20°C Photo 0.9A, 3 sec on 27sec off, cont. to 1.8 V @ 20°C 0 400 800 1200 1/06 Pulse Cycles * Delivered capacity is dependent on the applied load, operating temperature and cut-off