Too much smoke is one of the most common causes of excessive fuel usage and expensive service requirements. That is precisely why the smoke test is an indispensable part of any oil burner service job; and with the True Spot, an accurate smoke reading takes less than a minute. The True Spot smoke test method has long been recognized as the accepted standard for oil burner smoke tests. It is used by Underwriters' Laboratories in approval testing of oil burners; and it is the test method specified
All expendable items, such as electrochemical sensors, are warranted for a period of six months. THE FOREGOING WARRANTIES ARE EXCLUSIVE AND ARE GIVEN AND ACCEPTED IN LIEU OF (I) ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE: AND (II)ANY OBLIGATION, LIABILITY, RIGHT, CLAIM OR REMEDY IN CONTRACT OR TORT, WHETHER OR NOT ARISING FROM BACHARACH’S NEGLIGENCE, ACTUAL OR IMPLIED. The remedies
Figure 2. BatteryInstallation If batteries are accidently installed in the wrong polarity, a positive temperature coefficient (PTC) thermistor will protect the instrument’s electronic circuity. The instrument will operate once batteries are properly installed and the PTC thermistor is allowed to cool. 3.2 Probe Installation The probe comes disassembled. To add the probe tip: a. Loosen but DO NOT REMOVE the Knurled Nut (03-2023) on the main part of the Probe Assembly (19-3076). b. Insert probe tu
The instrument will operate once batteries are properly installed and the PTC thermistor is allowed to cool. If batteries are accidently installed in the wrong polarity, a positive temperature coefficient (PTC) thermistor will protect the instrument’s electronic circuitry. The instrument will operate once batteries are properly installed and the PTC thermistor is allowed to cool. Probe Installation Install the probe by sliding the end of its hose over the gas inlet port on the top right side of
6 – October 1999 Bacharach, Inc. 621 Hunt Valley Circle, New Kensington, PA 15068 PH: 724-334-5000 • FAX: 724-334-5001 • Web: E-mail: help@bacharach-inc.com Printed in U.S.A. ® Registered Trademark WARRANTY Bacharach, Inc. warrants to Buyer that at the time of delivery this Product will be free from defects in material and manufacture and will conform substantially to Bacharach Inc.’s applicable specifications. Bacharach’s liability and Buyer’s remedy under this warranty are limited to the repai
This continuous operating instrument quickly and accurately measures levels of CO between 0 and 1,999 ppm. Weighing just 8 ounces, the Snifit analyzers are light as a feather and small enough to fit in your shirt pocket or hold in the palm of your hand. With one button operation, the Snifit analyzers are simple to use. Special design features such as a zero adjustment control and a fast response sensor specific to CO gas make the Snifit analyzers perfect for measuring low levels of CO. 29 App
The 900-0056 uses advanced technolo- gy to monitor for carbon monoxide levels in your home and features a NighthawkTM, electrochemical sensor, the world’s most accurate carbon monoxide sensing technology*. The digital display feature allows for easy viewing of carbon monoxide levels. Consumer Benefits The Kidde 900-0056 AC powered, plug-in carbon monoxide alarm provides you and your family a warning signal against the dangers of carbon monoxide levels in your home. This alarm is easily installed
CO Alarm Model Number (Located on the back of alarm): CO Alarm Assembly Number (Located on back of alarm): Date of Manufacture (Located on back of alarm): Date of Purchase: Where Purchased: For questions concerning your Carbon Monoxide Alarm, please call our Consumer Hotline at 1-800-880-6788 Please have the following information ready when calling: SIGNALINGLISTEDUL ATTENTION: Please take a few minutes to thoroughly read this manual, which should be saved for future reference and passed on to a