Login:
Sorted: Name ↑   Downloads   Rate   Size ↑  

Baldor PM5418

downloaded: 1File size: 36 mb    Manafacture: Baldor  
Category: Portable Generators

When the instrument is in NICAM mode and the FM modulation is switched off (for example, by selecting the external modulation or by switching off the FM carrier), the RSSF bit is automatically set to LOW. The TEST key selects three special data sets. The TEST key has a stepping function and by repeatedly pressing the key, the signals DATA 1 - DATA 2 - DATA 3 are switched on. For DATA 3, both LEDs next the key are lit. The data sets do not comprise real NICAM data; they contain bit patterns to e

Baldor PM5415

downloaded: 6File size: 36 mb    Manafacture: Baldor  
Category: Portable Generators

The instrument allows 11 complete instrument setups to be recalled from memory via channel numbers if a channel number has been assigned to the vision carrier frequency. Refer to the table ’VHF/UHF Channel Frequencies for Different TV Systems’ in the appendix B can be helpful. - The assignment channel number - frequency can be random. - The channel number is written into the displayed memory. - Ten channel numbers can be stored in memory locations 0 to 9. - The 11th channel number is enga

Baldor PM5414V

downloaded: 6File size: 6 mb    Manafacture: Baldor  
Category: Portable Generators

The 1 st and 2nd square are PAL coded. This section indicates the proper functioning of the color demodulator part. The third section consists of four squares which are color coded but should not show any color at a well aligned color television or monitor: all four squares should be grey. Both R-Y squares are NTSC coded: the R-Y signal does not change direction 180° each line. The burst signal is PAL coded and ensures normal operation of the PAL switch in a color receiver. The third and fourt

Baldor TS130

downloaded: 106File size: 3 mb    Manafacture: Baldor  
Category: Portable Generators

Table of Contents Section 1 Product Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Safety Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Responsibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Baldor TS400

downloaded: 17File size: 3 mb    Manafacture: Baldor  
Category: Portable Generators

4-2 Operation MN2417 Figure 4-1 Trailer Component Identification Jack Coupler Coupler Handle Safety Chains Ball Coupler Jack Single or Double Axle Trailer Brake Safety Chains Trailer Pintle Engine Compartment Lift Hook Battery Compartment Tow Vehicle Mounted Pintle Hook Caution: Large “Engine Compartment Doors” on each side of enclosure must remain closed during operation. If doors remain open, engine will overheat due to insufficient air flow around engine. WARNING: If the trailer is not proper

Baldor TS60

downloaded: 10File size: 3 mb    Manafacture: Baldor  
Category: Portable Generators

Step: 1 kW; Range: 1 . 3000 kW CT Ratio Gen.set phases current transformers ratio. Step: 1 A; Range: 1 . 5000 A / 5A PT ratio Gen.set potential transformers ratio. Step: 0,1 V / V; Range: 0,1 . 500,0 V / V Nominal freq Nominal generator frequency (usually 50 or 60 Hz ) Step: 1Hz; Range: 45 . 65 Hz Gear teeth Number of teeth on the engine gear for the pick.up. Set to zero, if no pick.up is used. Engine speed is counted from the generator frequency. Step: 1; Range: 0 . 500 Note: Generator frequenc

Baldor TS35

downloaded: 1File size: 3 mb    Manafacture: Baldor  
Category: Portable Generators

c. Repeat steps a and b for the other Battery Hold Down Rod. Figure 3-6 Battery Installation Washers & Nut The + and . terminals of your battery may be different than shown. Be sure that the Positive lead is connected to the positive (+) terminal of your battery. Washers & Nut Battery (Install away from terminals) Battery Hold Down Bar Battery Hold Down Rod Battery Tray 6. Connect the positive lead to the positive (+) battery terminal. 7. Connect the negative lead to the negative (.) battery ter

Baldor TS80

downloaded: 22File size: 3 mb    Manafacture: Baldor  
Category: Portable Generators

Any maintenance instructions or recommendations in the engine owner’s manual take precedence over any of the following general recommendations. General: 1. Inspect the fuel system for leaks. Replace all defective components immediately. 2. Inspect and replace any fuel line that shows signs of deterioration. 3. Inspect all the fuel clamps to ensure they are tight. 4. Make sure the fuel cap fits snugly on the fuel tank and that the fuel tank contains no leaks. 5. Inspect and clean the battery post

Baldor TS175

downloaded: 2File size: 3 mb    Manafacture: Baldor  
Category: Portable Generators

Operation in any manner not described in this manual should be considered unsafe and should not be attempted. Never start the engine unless you have first verified that the installation and operation of the generator are as described in this manual. WARNING: Be sure that you are completely familiar with the safe operation of this equipment. This equipment may be connected to other machines that have rotating parts or parts that are controlled by this equipment. Improper use can cause serious or

Baldor TS250

downloaded: 3File size: 3 mb    Manafacture: Baldor  
Category: Portable Generators

After these checks have been performed and the system operation is verified to be good, refer to Section 5 Maintenance for periodic checks that must be performed at scheduled intervals to ensure continued operation with minimal problems. WARNING: Disconnect the battery’s ground terminal before working in the vicinity of the battery or battery wires. Contact with the battery can result in electrical shock when a tool accidently touches the positive battery terminal or wire. The risk of such shock





Category