– For rooms with a volume greater than 10m3 - no permanent ventilation is required. Note: Regardless of room size, all rooms containing the appliance must have direct access to the outside air via an openable window or equivalent. – Where there are other fuel burning appliances in the same room, BS 5440-2: 2000 should be consulted to determine the correct amount of free area ventilation requirements. – The above requirements allow also for use of a gas oven and grill but if there are other gas b
Important Notes Installation, and any demonstration, information or adjustments are not included in the warranty. The cooker must be installed by a suitably qualified and registered person in accordance with the relevant Standards. 24 24 Care and Maintenance Important: As a safety measure, before you start cleaning the cooker be sure to disconnect it from the mains supply. Do not use cleaning products with a chlorine or acidic base. Do not use a steam cleaner because the moisture can get into th
It is possible to cook several dishes simultaneously. IMPORTANT To open the bottom door operate as indicated in fig. 8. WARNING: The door is hot, use the handle. ATTENTION - MOST IMPORTANT Pay special attention not to touch the hot heating element inside the oven cavity. Fig. 8 11 Switch and the Temperature Selector Rotate the knob clockwise to set the oven for one of the following functions: Off as per fig. 9 Only the oven fan is on. The fan operates without the heating element, this function c
• Harby Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : General warnings GB IE Dear Customer, Thank you for choosing our product. This appliance is easy to use; read this handbook carefully before installing and using it, however. You will find the correct indications for the best installation, use and maintenance of the product. • Very important: keep this instruction booklet with the appliance in case you pass it on to someone else. • This
Setting up minimum flow rates: 1. Remove the control knobs. 2. Turn on the LP gas supply, light the burners and turn the controls to the minimum position, as indicated by the small flame. 3. Insert a 2.5mm screwdriver into the hole at the top of the tap and turn the adjustment screw fully clockwise as shown in figure 6. 4. Turn the controls to maximum position then quickly to the minimum position - make sure the flame does not extinguish. 5. Replace the knobs. LPG to Natural Gas Conversion This
• After use, please ensure that the gas taps are in the ‘Off” position. • Ensure that the appliance is correctly adjusted for the type of gas available before installation. • The use of a gas appliance produces heat and humidity in the room in which it is installed. Ensure that the room is well ventilated, either by the use of natural ventilation outlets (e.g. windows) or a ducted extractor. • This hob (Class 3) has been designed for use only as a cooking appliance. Any other use (e.g. heating r
Over time with use, the stainless steel surface may discolour; this is normal and does not constitute a fault with this appliance. Proprietary stainless steel cleaners are available. We recommend the CDA E-Cloth available from the CDA Sales Team for cleaning stainless steel surfaces. The enamelled parts of hobs are not suitable for cleaning in dishwashers; these should be washed by hand. IMPORTANT: • Steam cleaners must not be used when cleaning this appliance. • Ensure that all parts are correc