FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS. . CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. . PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS MULTI-FUEL BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. . SAVE THESE INSTRUCTIONS. .BRECKWELL HEARTH PRODUCTS 11/09 OWNER’S MANUAL TABLE OF CONTENTS INTRODUCTION .......................
AT LEAST THREE FEET FROM THE OPERATING STOVE. e. Maintain proper ventilation. It is important that adequate oxygen be supplied to the fire for the combustion process. Modern houses are often so well insulated that it may become necessary to open a window slightly or install an outside air vent to provide sufficient combustion air. f. Since heating with a solid fuel is potentially hazardous, even with a well made and thoroughly tested stove, it would be wise to install strategically placed smoke
Your blowers will never shut off and if the fire went out the auger will continue to feed pellets until the hopper is empty if you leave the POF thermodisk bypassed. 9. The high limit thermodisk has tripped or is defective. Using the owner’s manual, locate the high limit thermodisk. There is a red button located on the back of it. Press the red button. If you hear a click, the high limit had tripped. The stove should now function normally. To test if the thermodisk is bad, you can bypass it as d
For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. • PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury, or even death. • Save these instructions. PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED Manufactured by Breckwell Hearth Products Eugene, Orego
Some stove owners lightly spray an anti-creosote chemical on the fire to help reduce creosote formation within the stove. FIGURE 26 FIGURE 25 . . Air Switch Tube Air Switch Tube REAR VIEW – P24FS FIGURE 27a CONTROL BOARD CONVECTION BLOWER AIR SWITCH AUGER MOTOR AUGER SHAFT COMB. BLOWER SIDE CUTAWAY – P24FS FIGURE 27b 22 MAINTENANCE FIGURE 28a FIGURE 28b COMB. BLOWER AUGER MOTOR AIR SWITCH CONTROL BOARD CONV. BLOWER HIGH TEMP THERMODISK COMB. BLOWER POF THERMODISK PELLET HOPPER AUGER SHAFT CHIMNE
The fireplace and chimney should be cleaned thoroughly before starting the installation. We suggest painting the interior of particularly old and dirty fireplaces to seal any odors. In zero-clearance fireplace installations, when the fireplace opening is above the floor or raised hearth, the adjustable “Breckwell P24 Z-C Skirt” (part # A-ZC-SKRT), or “Breckwell P24 Z-C Legs” (part #A-S-ZCLEGS), can be used to bridge the gap between the hearth and stove bottom. (Refer to figure 13) A. ASSEMBLING
FREESTANDING INSTALLATION A. HORIZONTALLY THROUGH WALL (refer to Figure 8) NOTE: See “VENTING” and follow L-Vent chimney manufacturer’s instructions. 1. Position stove, adhering to clearances shown in Figures 1 & 2. 2. Locate position of hole in wall; directly behind stove exhaust vent (refer to figure 5). 3. Always maintain 3” clearance from combustible materials. 4. Install L-Vent wall thimble per L-Vent manufacturer’s instructions. 5. Attach enough piping to penetrate and extend at least 6” b
This safety switch has two functions. 1. To recognize an overheat situation in the stove and shut down the fuel feed or auger system. 2. In case of a malfunctioning convection blower, the high-temperature thermodisc will automatically shut down the auger, preventing the stove from overheating. NOTE: On some units, once tripped, like a circuit breaker, the reset button will have to be pushed before restarting your stove. On other units the thermodisk has no reset button and will reset itself once
For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. • PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury, or even death. • Save these instructions PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED Manufactured by National Steelcrafters of Oregon, Inc. D
If connected to an older, two-prong outlet, a separate ground wire should be run to a proper ground (refer this to a qualified technician). Always route the electrical cord so that it will not come in contact with any hot part of the stove. FIGURE 18 SPECIAL MOBILE HOME REQUIREMENTS WARNING: DO NOT INSTALL IN A SLEEPING ROOM. For installation in a mobile home, an outside source of combustion air must be used (See “COMBUSTION AIR SUPPLY”). The P2000 must be grounded to the steel chassis of the ho