|
Other manuals for this model:
manual abstract
Chapter 13
Alternative Rack Mounting (4–Post)
in the high-density racks and additional information for rack systems not listed in
this manual. You will need this information to complete a rack system installation.
Safety Precautions
Always keep the following safety and environmental issues in mind, especially if
you install the HP Netserver in a non-HP rack environment:
• Optimum Operating Environment – The optimum operating conditions
for the HP Netserver is in an environmental controlled computer room with
a temperature range of 20 to 22° C (68 to 72° F) at 40 to 60% relative
humidity.
• Maximum Ambient Temperature – Ensure the maximum ambient
temperature does not exceed 35° C (95° F).
• Elevated Operating Ambient Temperature – The ambient operating
temperature within a closed or multi-unit rack assembly may exceed the
room's ambient temperature. Ensure the temperature within the rack itself
does not exceed 35° C (95° F).
• Reduced Air Flow – As you mount equipment in the rack, ensure you
allow enough air flow for safe operation of the equipment. The Netserver's
fans will only operate correctly if both front and rear doors of the rack
allow free air flow (perforated openings), or are removed.
• Mechanical Loading – Uneven mechanical loading within the rack can
cause hazardous conditions. To prevent uneven loading plan to place the
heaviest components in the bottom of the rack, mounting all components as
low in the rack as possible.
• Circuit Overloading – Ensure the total configuration of equipment in the
rack does not overload the supply circuit. To this end, check the nameplate
ratings on all equipment. Consider the effect of circuit overloading on
overcurrent protection and supply wiring.
• Reliable Earth Grounding – Maintain reliable grounding of
rack-mounted equipment. Give particular attention to supply connections
not directly connected to the branch circuit (such as, using non-HP power
strips).
3
...Other models in this manual:
Desktops - HP NetServer LC 2000 (137.43 kb)
Desktops - HP NetServer LC 2000r (137.43 kb)
Desktops - HP NetServer LC II (137.43 kb)
Desktops - HP NetServer LC Plus (137.43 kb)
Desktops - HP NetServer LE (137.43 kb)
Desktops - HP NetServer LF (137.43 kb)
Desktops - HP NetServer LH 3/LH 3r (137.43 kb)
Desktops - HP NetServer LH 4/LH 4r (137.43 kb)
Desktops - HP NetServer LH 3000 (137.43 kb)
Desktops - HP NetServer LH 3000r (137.43 kb)
Desktops - HP NetServer LH (137.43 kb)
Desktops - HP NetServer LH 6000 (137.43 kb)
Desktops - HP NetServer LH 6000r (137.43 kb)
Desktops - HP NetServer LH II (137.43 kb)
Desktops - HP NetServer LH Plus (137.43 kb)
Desktops - HP NetServer LH Pro (137.43 kb)
Desktops - HP NetServer LM (137.43 kb)
Desktops - HP NetServer LP 1000r(1.13/1.26/1.40GHz) (137.43 kb)
Desktops - HP NetServer LP 1000r (137.43 kb)
Desktops - HP NetServer LP 2000r (137.43 kb)
Desktops - HP NetServer LP 2000r(1.13/1.26/1.40GHz) (137.43 kb)
Desktops - HP NetServer LPr (137.43 kb)
Desktops - HP NetServer LS (137.43 kb)
Desktops - HP NetServer LT 6000r (137.43 kb)
Desktops - HP NetServer LX Pro/LXe Pro (137.43 kb)
Desktops - HP NetServer LXr 8000 (137.43 kb)
Desktops - HP NetServer LXr 8500 (137.43 kb)
Desktops - HP NetServer LXr Pro8 (137.43 kb)
Desktops - HP NetServer LX (137.43 kb)
Desktops - HP NetServer LXr Pro (137.43 kb)