Login:
Votes - 3, Average rating: 4 ( )

User manual Kobe Range Hoods, model CH7948SQB

Manafacture: Kobe Range Hoods
File size: 2.56 mb
File name:
Language of manual:enesfr
Free link for this manual available at the bottom of the page



Other manuals for this model:
Fans - CH7948SQB (5.72 mb)enesfr

manual abstract


Mark the position of the duct cover-mounting bracket. Use reference E from Table 2 and measurements on Page 22-23. Attach and secure duct cover-mounting bracket with two screws (not provided). Refer to Figure 18. NOTE: Inner duct cover will cover the duct cover-mounting bracket. 4. Use aluminum or steel pipe to connect the plastic exhaust on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. 5. Connect electrical wires. Refer to “Wiring to Power Supply” on Page 17. 6. Slide the inner duct cover up 2 inches before sliding the entire duct cover onto the hood. Refer to Figure 19. Figure 18 Figure 19 7. Adjust the height of the inner duct cover to the duct cover-mounting bracket. Secure the inner duct cover with two (4x8 mm) screws (provided) as shown in Figure 20. Figure 20 Attach Together 8. Fasten outer duct cover to multi vent exhaust on the hood with four (4x8 mm) screws (provided). 13 WALL MOUNT INSTALLATION – REAR VENT ***This installation only applied with the purchase of a duct cover. Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. - Decide the location of the venting pipe from the hood to the outside. Refer to Figure 21. - A straight, short venting run will allow the hood to perform more efficiently. - Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood. - Use duct tape to seal the joints between pipe sections. - If necessary, prepare back wall frame with cross framing lumber for secure installation. - Using references on Table 2 and measurements on Page 22-23, decide the level of the lumber. Refer to Figure 22. Hood Preparation before Installation - Temporarily wire the hood to test for proper operation before installing. - Peel protective film off the hood and the duct cover (if any). - Remove the screws on the vent cover (rear) and cut along the line of the inner vent cover (rear) opening. Refer to Figure 23. - Cut the vent cover (rear) opening and reverse to the other side. Refer to Figure 24. Figure 21 Figure 22 Inner Vent Cover (Rear) Reversed Vent Cover (Rear) Figure 23 Figure 24 14 - If necessary, attach two rubber stands (provided) with two (4x8 mm) screws (provided) to the back of the hood. - Attach the hood-mounting bracket to the back of the hood with nine (3/16" x 3/8") screws (provided) as shown in Figure 25. Hood Installation CAUTION: If required to move the cooking range to install the hood, turn OFF the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE. 1. Using references on Table 2 and measurements on Page 22-23, mark the leveling point of the hood. Position two mounting screws (not provided) on the wall, leaving 1/8” away from the wall as shown in Figure 26. Mounting Screws Figure 25 Figure 26 2. Use aluminum or steel pipe to connect the exhaust opening at the rear of the hood to the ductwork. Use duct tape to make all joints secure and air tight. 3. Align hood-mounting bracket to the two screws on the wall and hook hood into place. Tighten screws to secure hood to the wall. CAUTION: MAKE SURE THE HOOD IS SECURE BEFORE RELEASING. 15 Duct Cover Installation 4. Mark the position of the duct cover-mounting bracket. Use reference E from Table 2 for references. Attach and secure duct cover-mounting bracket with two screws (not provided). Refer to Figure 27. NOTE: Inner duct cover will cover the mounting bracket. 5. Connect electrical wires. Refer to “Wiring to Power Supply” on Page 17. 6. Slide the inner duct cover up 2 inches before sliding the entire duct cover onto the hood. Refer to Figure 28. Figure 27 Figure 28 7. Adjust the height of the inner duct cover to the duct cover-mounting bracket. Secure the inner duct cover with two (4x8 mm) screws (provided) as shown in Figure 29. Figure 29 Attach Together 8. Fasten outer duct cover to multi vent exhaust on the hood with four (4x8 mm) screws (provided). 16 Wiring to Power Supply SAFETY WARNING RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY. Connect the electrical wires. -Connect three wires (black, white and green) to house wires and cap with wire connectors. Connect according to color: black to black, white to white, and green to green. -If necessary to hide the electrical wire connections, push wires back into the wiring box. Access the wire connections underneath the hood. Make sure wires do not slip between motor or any moving parts to prevent any damage. Final Assembly 1. Attach oil tunnel. Refer to Figure 30. 2. Refer to Figure 31. Slide the baffle filter into the hood. Push the baffle filter upward. Slide forward. Pull downward. Fit into place....

Other models in this manual:
Fitness Equipment - CH7930SQB (2.56 mb)
Fitness Equipment - CH7936SQB (2.56 mb)
Fitness Equipment - CH7942SQB (2.56 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category