Login:
Votes - 2, Average rating: 4 ( )

User manual Kobe Range Hoods, model CH7936SQB

Manafacture: Kobe Range Hoods
File size: 2.56 mb
File name:
Language of manual:enesfr
Free link for this manual available at the bottom of the page



Other manuals for this model:
Fans - CH7936SQB (5.72 mb)enesfr

manual abstract


BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY. Connect the electrical wires. -Connect three wires (black, white and green) to house wires and cap with wire connectors. Connect according to color: black to black, white to white, and green to green. -If necessary to hide the electrical wire connections, push wires back into the wiring box. Access the wire connections underneath the hood. Make sure wires do not slip between motor or any moving parts to prevent any damage. Final Assembly 1. Attach oil tunnel. Refer to Figure 30. 2. Refer to Figure 31. Slide the baffle filter into the hood. Push the baffle filter upward. Slide forward. Pull downward. Fit into place. 3. For bottom casing, repeat above steps. Refer to Page 23. 4. Turn power ON in control panel. Check all lights and fan operation. 5. Make sure to leave this manual for the homeowner. Figure 30 Figure 31 17 OPERATING INSTRUCTIONS This KOBE hood is equipped with four electronic controls with a 10-second standby startup & 30-second delay shutoff, two powerful centrifugal turbine impellers with baffle filters, and bright 12-volt 20-watt halogen lights. The four electronic controls are Light Control, Speed Control A, Speed Control B and the Power Control (On/Off). Refer to Figure 32. Figure 32 TURN ON: • Press Power Control (On/Off) button once. (Note: If any control button is not pressed within 10 seconds, power will be automatically turned off). • The hood will start on Low speed. Each press of the Speed Control button will cycle through the various speeds. • Press Speed Control A button to cycle from Low, Medium, High, or QuietMode™. Press Speed Control B button to cycle from Low, QuietMode™, High or Medium. (Note: Speed Control A or B will operate both fans. These two speed buttons vary the speed quicker.) • Press Light Control button to turn halogen light on. TURN OFF: • Press Power Control (On/Off) button once, panel lights will flash and power will be completely shut off after 30 seconds. OR • Press Power Control (On/Off) button twice, all power will be shut off immediately. • If only the lights are on, pressing Power Control (On/Off) button once will turn power off after 30 seconds. 18 MAINTENANCE For optimal performance, clean the range hood surface and baffles regularly. To Clean Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. *** Regular care will help preserve its fine appearance. 1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth. 2. If hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the surface of the hood. Avoid getting cleaning solution onto or into the control panel. Follow directions of the stainless steel cleaner. Caution: Do not leave on too long as this may cause damage to hood finish. Use soft towel to wipe off the cleaning solution, gently rub off any stubborn spots. Use dry soft towel to dry the hood. 3. DO NOT allow deposits to accumulate or remain on the hood. 4. DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface and cause rusting. 5. DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals, which may be harmful. Rinse with water after exposure and wipe dry with a clean lint free cloth. To Clean Baffle Filter/Oil Tunnel CAUTION: DRAIN OIL FROM BAFFLE FILTER & OIL TUNNEL REGULARLY TO PREVENT OVERFLOW. 1. Remove all the baffle filters and oil tunnel. 2. Using a sponge, wash with warm soapy water. Dry completely before returning into place. (Note: Baffle Filters are top rack dishwasher safe.) 19 To Replace Light Bulb CAUTION: HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL. NOTE: DO NOT TOUCH HALOGEN LIGHT WITH BARE HANDS, WHICH MIGHT CAUSE OVER HEAT AND SHORTEN THE LIFT OF LIGHT BULBS. 1. Make sure all controls are off, and range hood is unplugged. 2. Place the flat-headed screwdriver into the groove of the halogen light glass covering and the housing. . 3. Pop out the halogen light glass covering. . 4. Gently pull out the defective light bulb and discard. Light bulbs should be 12V 20W maximum. 5. Using a cloth, hold the new light bulb and push securely into light socket. 6. Return halogen light glass cover to the housing. . 7. Turn range hood ON to test for operation. 20 SPECIFICATIONS MODEL / SIZE CH7930SQB / 30” CH7936SQB / 36" CH7942SQB / 42" CH7948SQB / 48" COLOR Commercial Grade Stainless Steel CONSUMPTION / AMPERE 30” – 232W / 2.21A 36” – 232W / 2.21A 42” – 253W / 2.38A 48” – 258W / 2.41A NUMBER OF MOTORS 2 DESIGN 18-Gauge Seamless / Satin Finish FAN TYPE Twin Turbine Impeller EXHAUST Top – 6" Round 7" Round 3-1/4" x 10" Rectangular Rear – 3-1/4" x 10" Rectangular CONTROLS Electronic Control (4 Buttons) – 10-Second Standby Startup 30-Second Delay Shutoff HALOGEN LIGHTS 30” - 12V 2...

Other models in this manual:
Fitness Equipment - CH7930SQB (2.56 mb)
Fitness Equipment - CH7942SQB (2.56 mb)
Fitness Equipment - CH7948SQB (2.56 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category