User manual Goodman Mfg, model HAHM12DB - HCHM22DB

Manafacture: Goodman Mfg
File size: 947.49 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


• All field piping must be installed by a licensed refrigeration technician and must comply with all national and local codes. • Never plug unit(s) into an electrical outlet. • Do not touch compressor, pipes and valves without protective gloves during and after operation, because these parts may become hot (more than 100°C (212°F). • Explain the operating procedure of the air conditioner to the customer. Outdoor unit mounting leg dimension additional refrigerant amount =0.22oz./ft.>25’. 18/24 Btuh (Single Zone Only) • Charge additional refrigerant amount, ECR International Hyundai Ductless Split System11 MOUNTING OF THE INSTALLATION PLATE MOUNTING OF THE INSTALLATION PLATE Position the installation plate and check that it is level. IMPORTANT: Always mount the installation plate horizontally by aligning the marking line with the thread or using a level. 2. Mount the installation plate horizontally and securely on structural members (studs, etc.) in the wall with four (4) installing screws. (See Fig. 1) 3. Make a 2 9/16” hole through the wall. Hole should be angled down to the exterior. (See Fig. 2) 4. Use a city grade wall pipe (outer diameter : 2 3/8”) as a Fig. 1 18/24 Btuh 9/12 Btuh 3.43”4.21” 1.18” 5.53” 9.12”10.83” 2’ 6” 2’ 2.25” 5.28” 6.89” 6.89” 5.79” 1.38” .85” 12.60” sleeve to protect the interconnection cable and the pip ing. (See Fig. 2) Fig. 2 Fig. 3 Wall pipe ( field supplied OD: 2 3/8”) Wall-Hook Plate Mounting Approximately 3/16”– 3/8” Indoor Outdoor Fig. 2 Pipe hole O 2.56” 1.93” Anchor plug holeAnchor plug hole 3’ 4” 18.74”5.04” 3’ 2” 10.33” 10.33” 15.63” 8.52” 8.52” 6.63”6.63” 1.81” 1.81”1.81” 1.81” 1.40” 3.93”2.92”4.31” 3.72” 3.93” 7.44”9.84” INSTALLATION OF THE INDOOR UNIT(S) ! CAUTION ! When inserting the pipes, protect the ends from dust or moisture by covering the flare connections with a cap or tape. (Take care not to twist or crimp pipes during installation.) For Right Rear Sided, Right Sided and Lower Sided Piping NOTE: Do not apply excessive force to these parts. 1. For right side and lower side piping, cut the indoor unit base(s) with a hacksaw and deburr the cut end with a file. (See Fig. 5) 2. Hang the indoor unit(s) on the upper portion of the installation plate while inserting the vinyl-taped pipes through the wall hole. Engage the lower projection with the claws of the installation plate. (See Fig. 7) NOTE: Make sure that the unit(s) are securely mounted, by slightly shaking the indoor unit(s). Fig. 5 Fig. 6 Fig. 7 Right rear sided (recommended) Right sided Lower sided Cut here Hacksaw Interconnection cable Indoor unit pipes Indoor unit drain hose Vinyl tape For Left rear Sided and Left Sided Piping: (See Fig. 8) Fig. 8 Left rear sided Left sided The length of the cable which will be passed through the wall hole should be longer than 40”. Fig. 9 Suction pipe Discharge pipe Dimensions from the center of the installa4” 6” tion plate for reference. 1. Regarding the left rear sided and left sided piping, the pipes must...

Other models in this manual:
Air Conditioner & Split Systems - HACM09DB - HCCM99DB (947.49 kb)
Air Conditioner & Split Systems - HACM12DB - HCCM22DB (947.49 kb)
Air Conditioner & Split Systems - HACM12DB - HCCM22DB (947.49 kb)
Air Conditioner & Split Systems - HACM09DB - HCCM99DB (947.49 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category