|
manual abstract
MANUAL OPERATION • In case you are not satisfied with various conditions of automatic operation, you can select these conditions as you wish. • Select HEAT, DRY, Cool or CIRCULATE mode as you wish. OPERATION (Continued) OPERATION (Continued) HEAT MODE (Except Cool model) • In case of Cool and Dry mode, water may drop according to the contaminating status of air filter. In this case, please clean or replace the air filter with a new one. ! CAUTION ! • ..........Heating Capability: ~ This is a Heat pump type air conditioner which is heating the room by absorbing the outside air to the room. Therefore, as outside temperature drops, heating capability may be reduced. ~ If heating is not enough, please use another heating source together with the unit(s). • This is a warm air circulating system for heating the room. Therefore it will take time to heat the whole room. • ..........Features of Heating Operation: ~ If there is frost on the outdoor unit, the heating capacity will drop. Therefore, defrosting operates automatically (approx. 5 to 12 minutes) and the indicator light on the indoor unit(s) will blink (red). ~ The room and outdoor fan does operate during defrosting and the unit will not run during this time. • To change the air flow Up or Down Press the Flap button. • Up/Down Moving range of Airflow Direction Control Plate. • Left-right airflow direction is adjusted manually. • As shown in the figure below adjust the left-right airflow direction with the right/left air flow control plate. FAN SPEED, AIR FLOW DIRECTION • To operate the unit(s) effectively, it is recommended that you familiarize yourself with the following functions: • To change the fan speed Press the FAN SPEED button. • Cold air moves down, horizontal air flow is preferred when cooling. • Up/Down Air Flow • Right/Left Air Flow Control Plate Control Plate CIRCULATION MODE • If CIRCULATION mode is selected, the room air is circulated so that the temperature stratification in the room will be reduced. • You can select AUTO, HIGH, MED, or LOW speed. • In the AUTO fan speed, the room temperature, set temperature and the unit temperature are monitored so that the circulation can be properly controlled. ECR International Hyundai Ductless Split System6 mark will blink button. OPERATION (Continued) OPERATION CONDITION TIMER MODE (ON, OFF) mark will blink button. OPERATION (Continued) OPERATION CONDITION TIMER MODE (ON, OFF) • The timer can be set during any mode. Select the timer setting by pressing: ON-TIMER button or OFF-TIMER button. (Example) Time is AM 10:20. Air-conditioner is not in operation. How to start the air conditioner at PM 1:30 and stop it at PM 6:30. mark will blink 1. Press the button. button. Time can also be adjusted by 10-minute intervals by pressing button at center interval. 2. Press button to adjust ON TIMER to PM 1:30 (Time can be adjusted at hour intervals by pressing and holding 3. Press the TIMER button. 4. Press the 5. Press Time can be adjusted at hour interv...
Other models in this manual:Air Conditioner & Split Systems - HACM09DB - HCCM99DB (947.49 kb)
Air Conditioner & Split Systems - HACM12DB - HCCM22DB (947.49 kb)
Air Conditioner & Split Systems - HACM12DB - HCCM22DB (947.49 kb)
Air Conditioner & Split Systems - HACM09DB - HCCM99DB (947.49 kb)