Login:
Votes - 4, Average rating: 4.5 ( )

User manual Danby, model HACW09DB - HCCW09DB

Manafacture: Danby
File size: 947.49 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


supply to the condenser. ! CAUTION ! Make sure wire connections are secure otherwise electrical malfunction may occur. TEST RUN TEST RUN • After the test, set the lever to ON (I) position. The unit will stop the operation and hereafter the remote control will • Check the installation again. control the unit. • First, set the lever to OFF(O) position, then to ON(I) and TEST position slowly. (During the test, the indicator light will blink) 9/12 Btuh 18/24 Btuh CABLE CONNECTION 9/12 Btuh (Single or Multi-Zone) 1. Wiring between units should be cut to length. 2. Remove the wiring cover of the Indoor Unit(s) and the Outdoor Unit. 3. Insert the connection wire into the terminal block. ECR International Hyundai Ductless Split System15 CABLE CONNECTION 18/24 Btuh (Single Zone Only) ELECTRICAL SPECIFICATIONS AND SYSTEM PERFORMANCE 4. Fix the connecting wire between units, with wiring fixture. 5. Attach the wiring cover. CABLE CONNECTION 18/24 Btuh (Single Zone Only) ELECTRICAL SPECIFICATIONS AND SYSTEM PERFORMANCE 4. Fix the connecting wire between units, with wiring fixture. 5. Attach the wiring cover. Cooling Capacity SEER Heating Capacity (Btuh) (2) HSPF Volts/HZ/Phase Total Amps MCA Max. Fuse Nominal (1) Sensible HCW9000 9,500 7,030 10.9 --208/230/60/1 5.0 6.1 15 HCW12000 12,000 8,760 10.6 --208/230/60/1 6.2 7.6 15 HHW12000 12,000 8,760 10.4 12,500 7.2 208/230/60/1 6.2 7.6 15 HCW18000 20,000 14,200 10.7 --208/230/60/1 10.2 12.5 20 HHW18000 20,000 14,200 10.3 20,000 6.9 208/230/60/1 10.2 12.5 20 HCW24000 24,000 16,800 10.3 --208/230/60/1 12.1 14.8 25 HHW24000 24,000 16,800 10.0 24,000 6.8 208/230/60/1 12.0 14.8 25 (1) Indoor 80/67. F, Outdoor 95. F (2) Indoor 70/58. F, Outdoor 47. F Multi-Zone System Cooling Capacity (Btuh) SEER Heating Capacity (Btuh) (6) HSPF Volts/HZ/Phase Cond Fan Mtr Compressor Circuits 1 & 2 Indoor Fans Total Amps MCA HACR BRKR Min Volt Nominal (5) Sensible AMPS HP RLA LRA AMPS HP HMCW18000 (1) 18,000 12,600 10.9 --208/230/60/1 0.72 0.2 4.45 26 0.22 0.06 10.1 11.1 15 197 HMHW18000 (2) 17,400 11,700 10.0 17,700 6.8 208/230/60/1 0.72 0.2 4.45 26 0.22 0.06 10.1 11.1 15 197 HMCW24000 (3) 24,000 15,500 10.6 --208/230/60/1 0.72 0.2 5.85 29 0.22 0.06 12.9 13.4 20 197 HMHW24000 (4) 21,000 14,100 10.0 21,250 6.8 208/230/60/1 0.72 0.2 5.85 29 0.22 0.06 12.9 13.4 20 197 (1) HMCW18000 consists of two HACM09DB (9,000Btuh) air handlersand oneHCCM09DB condenser. (2) HMHW18000 consists of two HAHM09DB (9,000Btuh) air handlersand oneHCHM09DB condenser. (3) HMCW24000 consists of two HACM12DB (12,000 Btuh) airhandlers and one HCCM12DBcondenser. (4) HMHW24000 consists of two HAHM12DB (12,000 Btuh) airhandlers and one HCHM12DBcondenser. (5) Indoor 80/67. F, Outdoor 95. F (6) Indoor 70/58. F, Outdoor 47. F ECR International Hyundai Ductless Split System16 COMPLETION OF INTERCONNECTING TUBING • Insert the wall cap into the wall, and fill the gap with sealant to prevent rain or wind. • When using the pipe cover, fill the gap in the wall through hole in...

Other models in this manual:
Air Conditioner & Split Systems - HACM09DB - HCCM99DB (947.49 kb)
Air Conditioner & Split Systems - HACM12DB - HCCM22DB (947.49 kb)
Air Conditioner & Split Systems - HACM12DB - HCCM22DB (947.49 kb)
Air Conditioner & Split Systems - HACM09DB - HCCM99DB (947.49 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category