Login:
Sorted: Name ↑   Downloads   Rate   Size ↑  
downloaded: 1   File size: 409 kb   Manafacture: Heat & Glo LifeStyle  
Category: Fireplaces
@name

ST-38GT. WARNING: IF THE INFORMATIO. IN THESE INSTRUCTIONS IS NO. FOLLOWED EXACTLY, A FIRE O. EXPLOSION MAY RESULT CAUS. ING PROPERTY DAMAGE, PER. SONAL INJURY, OR DEATH. . Do not store or use gasoline or other flam. mable vapors and liquids in the vicinity of thi. or any other appliance. . What to do if you smell ga. . Do not try to light any appliance. . Do not touch any electrical switch. . Do not use any phone in your building. . Immediately call your gas supplier from . neighbor's phone. Fo

downloaded: 0   File size: 3 mb   Manafacture: Heat & Glo LifeStyle  
Category: Fireplaces
@name

Design and Installation Considerations Heat & Glo gas inserts are designed for installations into solid fuel masonry or factory built fireplaces that have been installed in accordance with the National, Provincial, State and local building codes. Fireplaces are to be constructed of non-combustible materials and, in the absence of local or regional codes, meet criteria of NFPA 211. No additional outside air source is required. Installation MUST comply with local, regional, state and national code

downloaded: 3   File size: 3 mb   Manafacture: Heat & Glo LifeStyle  
Category: Fireplaces
@name

instructions for safe use and operation. installation and operation. ? w tV A WARNING If the information in these instructions is not followed exactly, a fire may result causing property damage, personal injury, or death. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Do not overfire. Overfiring will void your warranty. Comply with all minimum clearances to combustibles as specified. Failure to comply may cause house fir

downloaded: 3   File size: 4 mb   Manafacture: Heat & Glo LifeStyle  
Category: Fireplaces

downloaded: 17   File size: 4 mb   Manafacture: Heat & Glo LifeStyle  
Category: Fireplaces
@name

• A gas log set must incorporate a gas shutoff. • Gas Log set requires the damper to be locked fully open. • Knockouts are provided on both sides of the fireplace and in refractories for 1/2 in. (13 mm) iron pipe. • Seal refractory around pipe with fireplace mortar or a high temperature, noncombustible sealant. B. Wood Burning Inserts WARNING! Risk of Fire! Improper installation of wood inserts may cause fireplace or chimney system to overheat. If a wood burning insert is being installed in this

downloaded: 4   File size: 3 mb   Manafacture: Heat & Glo LifeStyle  
Category: Fireplaces
@name

K • 11/06 10 Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 Part number list on following page. 7 Log Assembly (NG, LP) Exploded Parts Diagram Service Parts RCOR-HV-IPI Beginning Manufacturing Date: 6-03 Ending Manufacturing Date: ______ 1 2 4 3 15 5 6 Grate Bar Service Parts List (NG, LP) RCOR-HV-IPI IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure corre

downloaded: 6   File size: 5 mb   Manafacture: Heat & Glo LifeStyle  
Category: Fireplaces
@name

• Check fireplace opening for square to ensure proper fit of glass doors. Measure diagonals of fireplace opening to make sure they are equal. Top piece must overlap bottom piece Metal strips are placed 2 in. (51 mm) under the front of the fireplace and must extend beyond the front and sides of fireplace opening by 2 in. (51 mm). 1 in. (25 mm) overlap Minimum Figure 7.1 Position the Protective Metal Hearth Strips 2 in. 1 in. (25 mm) min. (51 mm) Raised Platform Floor overlap 2 in. (51 mm) Figure

downloaded: 3   File size: 3 mb   Manafacture: Heat & Glo LifeStyle  
Category: Fireplaces
@name

FIREBOX BOTTOMFIREBOX BOTTOM REMOTE CONTROL RECEIVER IPI CONTROL MODULE BATTERY TRAY LOWER ACCESS PANEL Figure 12.1 Valve Cavity Heat & Glo • SLR • 2143-900 Rev. B • 7/08 • 46 Heat & Glo • SLR • 2143-900 Rev. B • 7/08 Figure 12.2 Intellifi re Pilot Ignition (IPI) Wiring Diagram with Wall Switch or Thermostat Figure 12.3 Junction Box Detail NOTICE: DO NOT wire 110 VAC to wall switch. E. Junction Box Installation 1. Remove the two screws that hold the junction box bracket to the right corner of th

downloaded: 0   File size: 1006 kb   Manafacture: Heat & Glo LifeStyle  
Category: Fireplaces
@name

C • 12/07 Model: ST-42TVFL-IPI 1 Owner’s Manual Installation and Operation • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - Do not try to light any appliance - Do not touch any electrical switch. Do not use any phone in your building. - Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. - If you cannot reach your gas supplier, call the fire departme

downloaded: 2   File size: 5 mb   Manafacture: Heat & Glo LifeStyle  
Category: Fireplaces
@name

Adjust air shutter for longer vertical runs. See Figure 14.6. • Loosen the wing nut. • Push the air handle in to close the air shutter. • Pull the air handle out to open the air shutter. • Tighten the wing nut. NOTICE: If sooting occurs, provide more air by opening the air shutter. Figure 14.5 Fixed Glass Assembly Figure 14.6 Air Shutter G. Fixed Glass Assembly Removing Fixed Glass Assembly WARNING! Risk of Asphyxiation! Handle fi xed glass assembly with care. Inspect the gasket to ensure it is





Category