Note: A listed (and Commonwealth of Massachusetts approved) 1/2 in. (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. C. Gas Connection • Refer to Reference Section 16 for location of gas line access in appliance. • Gas line may be run through knockout(s) provided. • The gap between supply piping and gas access hole may be caulked with high temperature caulk or stuffed with non-combustible, unfaced insulation to prevent cold air infiltration. • Ensure that gas line does not come in contact with outer wrap of the appliance. Follow local codes. • Pipe incoming gas line into valve compartment. • Connect incoming gas line to the 1/2 in. (13 mm) connection on manual shutoff valve. WARNING! Risk of Fire or Explosion! Support control when attaching pipe to prevent bending gas line. • A small amount of air will be in the gas supply lines. WARNING! Risk of Fire or Explosion! Gas build-up during line purge could ignite. • Purge should be performed by qualified service technician. • Ensure adequate ventilation. • Ensure there are no ignition sources such as sparks or open flames. Light the appliance. It will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally. WARNING! Risk of Fire, Explosion or Asphyxiation! Check all fittings and connections with a non-corrosive commercially available leak-check solution. DO NOT use open flame. Fittings and connections could have loosened during shipping and handling. WARNING! Risk of Fire! DO NOT change valve settings. This valve has been preset at the factory. D. High Altitude Installations NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction. When installing above 2000 feet elevation: • In the USA: Reduce burner orifice 4% for each 1000 feet above 2000 feet. • In CANADA: Reduce burner orifice 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility. Heat & Glo • SL-550 / 750 / 950TV-IPI-E • 2119-900 Rev. J • 12/09 12 Electrical Information 12 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA C22.1. • Wire the appliance junction box to 110-120 VAC. This is required forr proper operation of the appliance. • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. • Low voltage and 110 VAC voltage cannot be shared within the same wall box. WARNING! Risk of Shock or Explosion! DO NOT wire 110V to the valve or to the appliance wall switch. Incorrect wiring will damage controls. B. Intellifire Ignition System Wiring • Wire the appliance junction box to 110 VAC for proper operation of the appliance. WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction box to a switched circuit. Incorrect wiring will override IPI safety lockout. • Refer to Figures 12.1 and 12.2, Intellifire Pilot Ignition (IPI) Wiring Diagram. • This appliance is equipped with an Intellifire control valve which operates on a 3 volt system. • Plug the 3-volt AC transformer into the appliance junction box to supply power to the unit OR install two D cell batteries (not included) into the battery pack before use. NOTICE: Batteries should not be placed in the battery pack while using the transformer. Remove batteries before using the transformer, and unplug the transformer before installing the batteries. Battery polarity must be correct or module damage will occur. C. Optional Accessories Requirements • This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control. Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories. D. Electrical Service and Repair WARNING! Risk of Shock! Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. WARNING! Risk of Shock! Replace damaged wire with type 105° C rated wire. Wire must have high temperature insulation. Heat & Glo • SL-550 / 750 / 950TV-IPI-E • 2119-900 Rev. J • 12/09 Heat & Glo • SL-550 / 750 / 950TV-IPI-E • 2119-900 Rev. J • 12/09 29 Figure 12.1 Intellifi re Pilot Ignition (IPI) Wiring Diagram with Wall Switch or Thermostat NOTE: 1. Ignition module, valve, pilot, and wall switch operate on 3 volts. 120 VAC is required at junction box unless equipped with battery back-up. RED IGNITION MODULE 3 ...
Other models in this manual:Fireplaces - SL-550TV-IPI-E (4.5 mb)
Fireplaces - SL-750TV-IPI-E (4.5 mb)