Login:
Votes - 2, Average rating: 3.5 ( )

User manual Procom, model PN750HYLB

Manafacture: Procom
File size: 518.8 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


How heater was malfunctioning . Type of gas used (propane/LP or natural gas) . Warranty card . Usually, we will ask you to return the defective part back to retail store. PARTS NOT UNDER WARRANTY: Contact authorized dealers of this product or Parts Central if they can’t supply original replacement part (s) Call PRO-COM’s Parts Department at 1-877-8865989 for referral information. When calling PRO-COM, have ready . Model number of your heater . The replacement part number 9 ACCESSORIES Purchase the accessories from your local dealer or Parts Central. If they cannot supply these accessories call PRO-COM’s Sales Department at 1-877-886-5989 for referral information. You can also write to the address listed on the back page of this manual. HIGH ALTITUDE DERATE In the U.S.A., Input BTU shall be derated 4%(1 orifice size) per 1000ft, for above 2000ft.. In Canada, input BTU shall be derated 10% (2 orifice size) at altitudes from 2000ft.to 4500ft.. SPECIFICATIONS Model L600HYLA/B PN750HYLA/B Btu (LP/NG) 60.000 75.000 Gas Type LP NG Ignition Piezo Piezo Inlet Gas Pressure* (In. of water) Maximum 14” 10.5” Minimum 11” 5.5” Dimensions, Inches (H x W x D) Stove 17 3/4” x22 7/8”x18 1/8” 17 3/4” x22 7/8”x18 1/8” Carton 15” x25 ”x20 1/4” 15” x25 ”x20 1/4” Weight, Lbs Stove 32/33 32/ 33 Shipping Weight 55/58 55/ 58 * For purpose of shipment adjustment. Minimum clearances: Bottom: (This appliance may not be place on any combustible materials) Top: 8 FT. (2.4m) Side /walls (around): 48 inch (1220mm) TROUBLESHOOTING POSSIBLE CAUSE OBSERVED PROBLEM REMEDY Burner does not light 1. Air in gas lines. 1. Continue holding down control knob. Repeat igniting operation until air is removed. 2. Inlet gas pressure is too low. 2. Check gas pressure. 3. Gas supply turned off. 3. Fully open gas supply. 4. Air passageway on heater blocked. 4. Check air passageway. 5. Burner orifice clogged. 5. Clean burner. 6. Control knob not in ING/ON position. 6. Turn control knob to ING/ON position. 7. Control knob not fully pressed in while7. Press down control knob. in ING/ON position. 1. Ignitor electrode positioned wrong. 1. Reposition ignitor. When ignitor buttons 2. Ignitor broken. 2. Replace pilot pressed in, there is no 3. Broken ignitor cable. spark at safety Pilot. 3. Replace ignitor cable. 4. Ignitor electrode not connected to ignitor cable. 4. Connect electrode to ignitor cable. 1. Damaged thermocouple. 1.Replace thermocouple. Burner fire does not last. 2. Thermocouple electrode corrosion. 2. Clean thermocouple electrode. 3. Damaged control valve. 3. Replace control valve. 4. Control knob not pressed long enough. 4. After pilot lights, keep control knob pressed in for 30 seconds. 5. Thermocouple connection loose at control valve. 5. Hand tighten connection or replace thermocouple. 6. Pilot flame not touching thermocouple. 6. Contact qualified service man. 10 PARTS LIST PL600HYLA/PL600HYLB PN750HYLA/PN750HYLB 11 ILLUSTRATED PARTS BREAKDOWN PL600HYLA / PL600HYLB PN750HYLA / PN750HYLB 12 WARRANTY INFOR ATION KEEP THIS WARRANTY Model: Serial No. Date Purchased Always specify model and serial numbers when communicating with PRO-COM. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. LIMITED WARRANTY PRO-COM OUTDOOR CAMPFIRE PRO-COM warrants this product to be free from defects in materials and components for one (1) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions, to make a claim under this warranty, the Bill of Sale or cancelled check must be presented. This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a PRO-COM Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or PRO-COM who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit. This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transporta tion and any and all such other costs related to repairing a defective heater will be the responsibility of the owner. TO THE FULLEXTENTALLOWED BY THE LAW OF THE JURISDICTION THATGOVERNS THE SALE OF THE PRODUCT, THIS EXPRESS WARRANTY EXCLUDES ANYAND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANYAND ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITYA...

Other models in this manual:
Fireplaces - PL600HYLA (518.8 kb)
Fireplaces - PL600HYLB (518.8 kb)
Fireplaces - PN750HYLA (518.8 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category