manual abstract
Apply Teflon tape or pipe dope to the steel fittings before making any connection. BE CAREFUL! Make sure all gas connections are snug, but not over tighten! 2. Extend the gas supply system using1/2” black iron pipe from current house supply. This may be accomplished by a teeing off” or tapping into a convenient gas line connection; installing the necessary pipe for the distance required; and then installing a manual valve at exterior house wall. If pipe is to pass though a foundation or house wall, make sure to re-seal the area around the pipe with weather sealant. 3. From manual valve, extend piping to the campfire. 3 Location Continue Note :If pipe is to be placed in an underground trench, check with local codes for required depth and material construction. 4. Connect the 3/8” male flare brass fitting (furnished with campfire) to the 1/2” steel piping making sure to clean the pipe threads and use Teflon tape or pipe dope.(FLEX LINE NOT SUPPLIED) 5. Connect the 1/2” female X 3/8” male flare brass fitting to the 3/8” female brass flare fitting, as sembled on the right side of the gas line, of the right side of the campfire. NOTE: Brass to brassw connections do not require teflon tape or pipe dope. (Note: show drawing of hard piping installation. Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the area of the appliance. . Never leave the appliance unattended during operation. Clothing or other flammable materials should not be placed on or near the appliance. • Any guard or other protective device removed for servicing the appliance must be replaced prior to operating the appliance • Installation and repair should be done by a qualified service person.. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required as necessary. It is imperative the control compartment, burners and circulating air passageways of the appliance be kept clean. • Inspect the fuel supply connection before each use of the appliance. Storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply. (natural gas line or LP gas) LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSZ223.1, also known as NFPA54*. Available from : American National Standards Institute, INC. 1430 Broadway, New York, NY10018 National Fire Protection Association, INC. Battery march Park Quincy. MA 02269 Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of control system and any gas control which has been under water. IMPORTANT: Installation of natural gas and LP should be done by a qualified installer, service agency or gas supplier. The appliance and its manual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1/2 psig (3.5kPa). This appliance must be isolated from the gas supply piping system by closing its manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa). 4 Installation LOGS LIST PL600HYLA PN750HYLA FIG 2 The LOG sets for PL600HYLA/ PN750HYLA PL600HYLB PN750HYLB FIG 3 The LOG sets for PL600HYLB/ PN750HYLB 5 Installation continue Check to make sure you have the correct parts before 7. Install the No.#1 log as indicated on base log .Fix assembling. the log on the bracket by the screw . . Logs: 5 (FIG.-6). Caution: Some of the steel edges may be sharp. Please use caution when assembling the unit. INSTALLATION INSTRUCTIONS: 1. Remove log from inside the box. Please note each log fits the number marked on foam package. 2. Next remove campfire from box. 3. You may use bricks or blocks to create your sur-Fig. 6 Install the LOG #1 round to place your campfire on. 4. Make sure that the campfire is placed on a flat surface. 5. Check the log piece (FIG-4). 8. Install the No.#2 log as indicated on base log. (FIG.-7). Fig.-4 Check the log piece 6. Make sure that the logs were installed correctly. Fig. -7 install the LOG #2 (FIG.-5).(Base logs are pre-installed.) 9. Install the No.#3 log as indicated on the base log ( FIG.-8). Fig. -8 install the LOG #3 Fig.-5 Install and check the base logs 6 Installation (continue) 11. install the No. # 4 log as indicated on the base (FIG.-9). Fig. -9 Install the LOG #4 12. Install the No. #5 Log as indicated on the base log (FIG. 10). FUEL REQUIREMENTS: Natural gas models l - Connect the ON/OFF gas valve of the appliance to the incoming gas supply line. See Figure 10. -Make certain all gas connections are right. -Turn the ON/OFF valve at the appliance slowly to the “ON” position. Us...
Other models in this manual:Fireplaces - PL600HYLA (518.8 kb)
Fireplaces - PN750HYLA (518.8 kb)
Fireplaces - PN750HYLB (518.8 kb)