Login:
Sorted: Name ↑   Downloads   Rate   Size ↑  
downloaded: 0   File size: 356 kb   Manafacture: Carrier  
Category: Water Dispensers
@name

Across-the-line start is not available. 20 Table 5A — Compressor Electrical Data, 30HXC Units (cont) UNIT SIZE 30HXC NAMEPLATE V-Hz (3 Phase) COMPRESSOR NUMBERS A1 B1 RLA LRA RLA LRA 208/230-60 * * * * 460-60 103.1 685 103.1 685 575-60 82.4 548 82.4 548 186 380-60 124.8 757 124.8 757 230-50 * * * * 346-50 * * * * 380/415-50 128.6 856 128.6 856 208/230-60 228.8 433 228.8 433 460-60 103.1 216 103.1 216 575-60 82.4 173 82.4 173 186-WD 380-60 124.8 239 124.8 239 230-50 212.5 432 212.5 432 346-50 141

downloaded: 16   File size: 4 mb   Manafacture: Carrier  
Category: Water Dispensers
@name

It incorporates significant breakthroughs in water-cooled chiller technology to provide excellent reliability and achieve superior efficiencies at true operating conditions without compromising the environment. The 23XRV chiller provides: • Variable speed, positive displacement screw compressor. • Air Conditioning, Heating, and Refrigerant Institute (AHRI) certified efficiencies to 0.33 kW/ton (AHRI IPLV). • Chlorine-free HFC-134a refrigerant. • IEEE-519 compliance for harmonic distortion. • An

downloaded: 105   File size: 356 kb   Manafacture: Carrier  
Category: Water Dispensers
@name

NOTES: 1. Main power must be supplied from a field-supplied fused electrical service with a (factory-or field-installed) disconnect located in sight from the unit. 2. Control circuit power must be supplied from a separate source through a field-supplied disconnect. The control circuit accessory transformer may be applied to power from the main unit power supply. 3. Maximum incoming wire size for each terminal block is 500 kcmil. 4. Maximum allowable phase imbalance is: voltage, 2%; amps, 5%. 5.

downloaded: 0   File size: 217 kb   Manafacture: Carrier  
Category: Water Dispensers
@name

Be sure you understand and follow the procedures and safety precautions contained in the machine instructions as well as those listed in this guide. DO NOT USE OXYGEN or air to purge lines, leak test, or pressurize a machine. Use nitrogen. NEVER EXCEED specified test pressures. For the 16DF machine, the maximum pressure is 12 psig (83 kPa). For the chilled/hot water and condensing water piping, the maximum pressure is stamped on the machine. WEAR goggles and suitable protective clothing when han

downloaded: 10   File size: 249 kb   Manafacture: Carrier  
Category: Water Dispensers
@name

1 - 07KA Water-Cooled Condensing Unit *Factory charge. Refer to Refrigerant Charging, page 3, for charging details. tUse Carrier PP-33-2, Texaco Capella Bl or Suniso 3G Dual Inhibited oil. NOTE: High and low pressurestats cut-in and cutout points are not adjustable. Table 2 - Electrical Data (60-Cycle) COND UNIT 07KA VOLTS PHASE BRANCH CIRCUIT NDSV LRA FLA MAX KW WSA Wire Size (AWG No) Max Ft Wire Wire Size (AWG No) Max Ft Wire Fuse Amp* 002310 230 1 230 49 0 12 0 2 75 15 2 12





Category