Login:
Votes - 0, Average rating: 0 ( )

User manual Bosch, model AI541120/01

Manafacture: Bosch
File size: 741.73 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



Other manuals for this model:

manual abstract


Adequate incoming air must be ensured. The applicable construction and safety regulations must be observed. Adequate incoming air must be ensured if a wood, coal, gas or oil heater or an open hearth is operated in the same room as the one in which the hood is installed. Safe operation is possible whenever the partial vacuum in the place where the firing equipment is installed does not exceed 4 Pa (0.04 mbar). This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/exhaust air wall boxes or other technical means. Flexible aluminium pipes, corrosion-protected sheet metal pipes and exhaust air pipes whose material conforms to fire B1 in accordance with DIN 4102 can be used. Exhaust air pipes should have a nominal diameter of 150 mm. exhaust air pipes whose material conforms to fire B1 in accordance with DIN 4102 can be used. Exhaust air pipes should have a nominal diameter of 150 mm. Pay particular attention to ensuring that – the exhaust air ducts and pipes are kept as short as possible – the pipes are not laid at an acute angle, but as bends and that they are inserted into the shaft at an inclined upward angle and – there are no cross-sectional constrictions in the upward direction (this reduces the volume flow). As standard, the blow-out opening of the extractor hood is in the upward direction. To pass exhaust air through the outer wall, we recommend the use of our telescopic wall box TM 150-045 (O 150). Note: To prevent the ingress of water, e.g. condensate or rain water from an uncovered exhaust air shaft, our condensate separator RV 060-150 must be installed in the exhaust air line. The condensate separator must still be acciessible after installation. The duct units listed below are available depending on the height of the ceiling: IInstallation accessories for exhaust air mode Stainless steel-design ventilation duct: LK 010-016 for ceiling heights of 2.23 -2.41 m LK 010-026 for ceiling heights of 2.41 -2.73 m LK 010-036 for ceiling heights of 2.73 -2.99 m Aluminium-design ventilation duct: LK 011-016 for ceiling heights of 2.23 -2.41 m LK 011-026 for ceiling heights of 2.41 -2.73 m LK 011-036 for ceiling heights of 2.73 -2.99 m Installation accessories for circulating air mode Stainless steel-design ventilation duct: LK 010-126 for ceiling heights of 2.41 -2.73 m LK 010-136 for ceiling heights of 2.73 -2.99 m Aluminium-design ventilation duct: LK 011-126 for ceiling heights of 2.41 -2.73 m LK 011-136 for ceiling heights of 2.73 -2.99 m The dimensions above refer to a distance of 1.60 m from the floor to the bottom edge of the hood. If required, custom made duct units are available at an extra charge. The electrical socket must be placed within the ventilation duct on the ceiling. 410,5 1200 700 261 630 - 1390 Fig. 18 2,23 - 2,99 m ceiling height min. 600 over electric hob min. 700 over gas hob To use above gas cooker / gas hob Important: do not use all burners on the highest setting simultaneously over a longer period of time (max. 15 minutes). This will pose a risk of burns when touching the hot appliance exterior or parts of the extractor hood may become damaged. Switch the extractor hood to the highest setting when three or more burners of a gas cooker are used simultaneously. The following note applies to extractor hood AI 542/543 only; these models do not have an integrated fan: The extractor hood can only be used in exhaust air mode. The exhaust air is conveyed upwards through an externally attached fan via a ventilation shaft or directly into the open air through the outer wall. The extraction function is realised by an external fan module. We recommend the fan modules GB 032-107 or GB 052/053-140 from our Gaggenau range; the extractor's electronic circuitry is optimised for these fan modules. For the electrical connection between the extractor hood and external fan see installation instructions for the external fan. For safety reasons, if the connecting cable to the external fan has been damaged, it must be replaced by the manufacturer or the after sales service or similarly qualified persons. 15 Installation of the extractor hood: 1. Using the drilling template mark the position of the screws on the ceiling. 2. Drill 4 holes O 8 mm for the wall plugs. Push the plugs flush with the ceiling (Fig. 19). 3. Turn two screws to a 10 mm gap. Both screws are placed in a position, in which at a later stage of the installation the key-holes of the supporting frame are found (namely back left and front right from the control panel of the hood). 4. Adjust the support frame to the desired height and secure with 8 screws (12 screws for the longer ventilation ducts). The length of the support frame can be adjusted in steps of 20 mm (Fig. 20). Note: ensure that the minimum distance between the hob and the extractor hood is maintained - 600 mm for an electric hob and 700 mm for a gas hob. Circulating air mode on...

Other models in this manual:
Range Hoods - AI542120/01 (741.73 kb)
Range Hoods - AI542121/01 (741.73 kb)
Range Hoods - AI543120/01 (741.73 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category