manual abstract


Tag disconnect switch with lockout tag. ! WARNING Upflow A06374 Horizontal Downflow A06371 Airflow Airflow Airflow A06517 Fig. 4 --- Perfect Airt Air Purifier Cabinet Orientation GAPAB 4 Step 3 —Mount Cabinet a. Turn off power to the heating and cooling system. b. Remove the existing fan coil filter and discard. Excessive system static pressure may result if the Perfect Airt Air Purifier is used with other filtration devices. c. Remove the air purifier cartridge and enhancement module from the Perfect Airt Air Purifier cabinet. d. Position the cabinet between the fan coil and return air duct (see Fig. 4 and 5). A transition duct may be required. NOTE: The fan coil cabinet screws holding the filter rack should be used to attach the air purifier cabinet. e. Gasket tape between the fan coil and the air purifier cabinet is already factory installed. f. Mounting holes are provided for fan coil attachment. g. Use return duct adapters provided to attach return ductwork (See Fig. 6). h. Seal seams with tape or caulking after the Perfect Airt Air Purifier cabinet has been secured. ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than 1 disconnect switch. ! WARNING UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage. Cabinets will support a maximum weight of 400 lbs when installed beneath a vertical fan coil or air--handling unit. When setting fan coil on cabinet, do not drop it into place. Position the fan coil correctly on the cabinet to prevent a corner from slipping down and damaging the cabinet or its components. ! CAUTION Mounting Cabinet Vertical Mounting Cabinet Horizontal Return Duct Adapters (x4) Return Duct Adapters (x4) A06389 A06388 Fig. 5 --- Mounting Perfect Airt Air Purifier Cabinet for Fan Coils A06392 Fig. 6 --- Use of Return Duct Adapters GAPAB 5 Step 4 —Wiring a. Ensure power has been removed from the heating and cooling system. b. Turn the Perfect Airt Air Purifier power switch off. c. Connect the power cord and the flow sensor cord to the power supply connector and the flow sensor connector (see Fig. 7 and Fig. 8). NOTE: The power cord can be routed through the opposite side of the cabinet. Zip ties have been enclosed to secure the power cord to the side of the power supply. NOTE: Cable connector and block--off plates will need to be removed and re--installed if the power cord is re--routed. Screws on the cable connector clamp should be tightened to 9 in. -- lbs. torque. NOTE: The Perfect Airt Air Purifier is to be powered by 208/230Vac/60 Hz. NOTE: The Perfect Airt Air Purifier should only be powered when airflow is present. An airflow sensor is factory--installed (See Fig. 2 and Fig. 11). In order to bypass the airflow sensor, use the special bypass jumper included in the parts bag. With the bypass jumper in place, the air purifier will be on at all times when connected to electrical line power (see Fig. 10). d. Attach the quick connect terminals to the fused power connector leads (in parts bag attached to power cord) and connect to incoming field power. Attach the ground ring to fan coil chassis ground. (See Fig. 10.) ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than 1 disconnect switch. ! WARNING EQUIPMENT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. This unit cannot be powered directly from blower motor leads. Do not wire directly to blower motor. Wiring to blower motor will damage power supply and void warranty. ! CAUTION A06414 Fig. 7 --- Flow Sensor Cable Installed A06413 Fig. 8 --- Power Cord Installed AIR FLOW SENSOR CABLE OR AIR FLOW SENSOR BYPASS PLUG MUST BE CONNECTED TOTHE POWER SUPPLY IN ORDER TO ACTIVATE THE AIR PURIFIER NOTICE A06670 Fig. 9 --- Airflow Sensor Bypass Plug Installed GAPAB 6 TO FAN COIL FIELD POWER CONNECTION FUSED POWER CONNECTOR LEADS FROM INSTALLATION COMPONENTS (IN BAG ATTACHED TO POWER CORD) AIR PURIFIER POWER CORD TO FAN COIL FIELD POWER CONNECTION TO L2 FIELD POWER SUPPLY TO L1 FIELD POWER SUPPLY 5 AMP IN-LINE FUSES GROUND: ATTACH TO FAN COIL GROUND (CHASSIS) CABLE CONNECTOR TO SECURE POWER CORD TO FAN COIL CABINET A06515 Fig. 10 --- Fan Coil Chassis Ground Air Flow Sensor 1) Slide flow sensor tabs into support bracket 2) Rotate flow sensor and clip into bracket A06412 Fig. 11 --- Flow Sensor Install GAPAB START- --UP AND OPERATION Step 1 — Checking Air Purifier Operation ! WARNING ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than one (1) disconnect switch. a. Attach the Perfect Airt Air Purifier d...

Other models in this manual:
Air Cleaners - PERFECT AIR 2020 (1.89 mb)
Air Cleaners - PERFECT AIR 2420 (1.89 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category