manual abstract


Step 1 —Check that the Perfect Airt Air Purifier door is installed. NOTE: A magnet in the door (see Fig. 8) is used to activate a safety switch in the power supply when the door is installed. The power supply will not energize the air purifier unless the safety switch is activated. Step 2 —Check that the Perfect Airt Air Purifier power switch is in the on (closed) position. Step 3 —Confirm that the fan coil blower is operating. Step 4 —Confirm that 208/230 VAC power is provided. Attach power supply connector to the air purifier when the fan coil blower is operating. NOTE: Even though power is supplied to the Perfect Airt Air Purifier, it will not turn on unless the airflow sensor senses airflow or the airflow sensor’s bypass plug is inserted. Step 5 —Confirm that the airflow sensor cable or airflow sensor bypass plug is connected to the power supply (See Fig. 7). Step 6 —If still not functioning, disconnect the airflow sensor cable and the power cord from the power supply. Remove the enhancement module from the air purifier cabinet and inspect the airflow sensor (See Fig. 11). Confirm the airflow sensor is properly seated in its bracket and the airflow sensor cable is connected to the back of the sensor. Replace the enhancement module. Step 7 —Reconnect the power cord to the power supply and insert the airflow sensor disable jumper (from parts bag). If the power indicator light illuminates, then replace the airflow sensor. Install the door onto the air purifier and turn the power switch to the “ON” position. Step 8 —If all of the above steps are completed and the power indicator light is still not illuminating, replace the power supply on the enhancement module. Note that there are no serviceable parts within the power supply. GAPAB 9 SPECIFICATIONS AND DIMENSIONS Table 1—Specifications and Dimensions GAPAB Specifications GAPABXBB1620 GAPABXBB2020 GAPABXBB2420 Color Taupe Metallic Taupe Metallic Taupe Metallic Cabinet Material 20 Ga. Powder Coated Steel 20 Ga. Powder Coated Steel 20 Ga. Powder Coated Steel Electrical 208/230v/60Hz 208/230v/60Hz 208/230v/60Hz Maximum Airflow (CFM) 1350 1800 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 Equivalent to MERV 15 Replacement Cartridge GAPCBBAR1620 GAPCBBAR2020 GAPCBBAR2420 Initial Pressure Drop (in w.c.) (at maximum airflow) .22 .25 .22 Dimensions GAPABXBB1620 GAPABXBB2020 GAPABXBB2420 A 18-- 1/2 22 25-- 1/2 B 15-- 1/8 18-- 5/8 22-- 1/8 C 13-- 1/8 13-- 1/8 13-- 1/8 D E 17-- 5/8 19-- 3/4 21-- 1/8 19-- 3/4 24-- 5/8 19-- 3/4 F 22-- 1/4 22-- 1/4 22-- 1/4 G 11-- 1/4 11-- 1/4 11-- 1/4 C 1 3/16" G E F 3/8" (Typical Top & Bottom) A BD 1 3/16" 1 1/2" 1 3/16" A06368 Fig. 15 --Dimensions 10 WARRANTY FOR SERVICE OR REPAIR, FOLLOW THESE STEPS IN ORDER: FIRST: Contact the installer. You may find their name on the product or in your Homeowner’s Packet. If the installer’s name is not known, call your builder or home retailer if yours is a new residence. SECOND: Contact the nearest distributor. (See telephone yellow pages.) THIRD: Contact: Bryant Heating and Cooling Systems Consumer Relations P.O. Box 4808 Syracuse, New York 13221 Telephone: 1- --800- --428- --4326 Model No. ____________________________________________ Unit Serial No. ______________________________________ Date of Installation _____________________________________ Installed by _________________________________________ Name of Owner _______________________________________ Address of Installation _________________________________ PERFECT AIRt AIR PURIFIERS FIVE- --YEAR LIMITED WARRANTY- --- --- --Bryant Heating & Cooling Systems (herein after referred to as ‘Company’) warrants this product to be free from defects in material and workmanship. If a defect is found within five years from the date of original installation of the product (whether or not actual use begins on that date) Company will provide a new or remanufactured part, at Company’s sole option, to replace any defective part, without charge for the part itself. This warranty does not include labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either defective parts, or replacement parts, or new units. WARRANTY CONDITIONS: 1. Warranties apply only to products in their original installation location. 2. Installation, use, care, and maintenance must be normal and in accordance with instructions contained in the Owner’s Manual and Company’s service information. 3. Defective parts must be returned to the distributor through a registered servicing dealer for credit. 4. All work shall be performed during normal working hours. LIMITATIONS OF WARRANTIES – ALL IMPLIED WARRANTIES AND/OR CONDITIONS (INCLUDING IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE) ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY OR CONDITION IS GIVEN AND APPLIES. SOME STATES OR PROVINCES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY OR CON...

Other models in this manual:
Air Cleaners - PERFECT AIR 1620 (1.89 mb)
Air Cleaners - PERFECT AIR 2020 (1.89 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category