Manafacture: Field Controls
File size: 1.03 mb
File name: 46453400.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


i. Remove the two hex nuts and angled bracket from included bagged hardware. ii. Install the angled bracket and secure to the unit base with the hex nuts provided. (See Figure 14) NOTE: Be sure to note location of lamp hole in bracket relative to unit base. 6. Mount the unit base to the duct using the four mounting screws provided. (See Figure 15) 7. Remove tag and alcohol wipe from lamp. Wipe off lamp being sure not to touch lamp with bare hands. The oils in your hands cause a reduction in lamp output. 8. Insert lamp through the hole until lamp cannot be inserted any further. (See Figure 16) Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. page 6 9. Swing the swivel bracket over the end of lamp. Hand-tighten the wing nut on the stud. Be careful not to over tighten the wing nut. The porcelain at the lamp base may crack when over tightened. (See Figure 17) 10. Plug ballast plug into end of lamp. (See Figure 18) 11. Snap cover onto the unit base. (See Figure 19) 12. Plug the LED wire from the cover onto the board. (See Figure 20) 13. Close the cover and tighten cover screw. (See Figure 21) 14. Plug the power cord into a standard electrical outlet. NOTE: Seal the joints and seams of the plenum near the mounting location to reduce any direct viewing of light. (See Figure 1) 15. Press the power switch to the ON position. (Light on switch should be on, indicating power.) 16. Look through view port in the box cover to be sure the lamp is working. You should see a blue glow. (The view port is covered with a plastic lens that blocks the UVC rays.) If equipped, the LED light will show a continuous GREEN color indicating proper unit operation. 17. If the lamp is not glowing, follow steps 8-14 again. If lamp still does not glow, contact technical support at 252-522-3031 for further assistance. Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. page 7 INCORPORATING A THERMOSTAT (Be sure to follow any applicable state or local codes.) The UV Aire units supplied with a circuit board allow for the automatic operation of the UV lamp when the there is a call for heating or cooling by the thermostat. After the call for heat has been satisfied, the UV Aire unit will operate for 45 minutes then shut off. 1. Turn off power switch on the UV Aire unit and unplug the unit before doing any wiring. 2. Loosen the cover screw and open the unit cover. 3. Locate terminals 1-2 on the circuit board and remove the jumper wire. 4. Wire to terminal...

Other models in this manual:
Air Cleaners - UV-12HPC (1.03 mb)
Air Cleaners - UV-12C (1.03 mb)
Air Cleaners - UV-28HPC (1.03 mb)
Air Cleaners - UV-28HP (1.03 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category