Login:
Sorted: Name ↓   Downloads   Rate   Size ↑  
downloaded: 0   File size: 3 mb   Manafacture: American  
Category: Water Heaters
@name

Such pans should be fabricated with sides at least 2” deep, with length and width at least 2” greater than the diameter of the heater and must be piped to an adequate drain. The pan must not restrict combustion air flow. clearances This water heater is approved for installation on combustible flooring (with NSF Leg kit #9003425205) in an alcove when the minimum clearance from any combustible construction is as indicated in Figure 6 and Table 4. In all installations the minimum combustible cleara

downloaded: 2   File size: 3 mb   Manafacture: American  
Category: Water Heaters
@name

tuBe inlet installation figure 19 code restrictions Use of the top inlet water connection is not permitted on installations in the state of North Carolina, due to the material of the tube (Polypropylene). Where such code restrictions exist, use only lower inlet tank connection. This may also require a heat trap -check local codes. The “Top Outlet” connection may still be used on these applications. Plug or cap all unused openings in the tank before filling with water. temperature setting should

downloaded: 0   File size: 2 mb   Manafacture: American  
Category: Water Heaters
@name

NOTE: The Temperature Set-point cannot be adjusted beyond the limits of the current Mode selected. Burner in Operation When the burners are in operation and flame is detected by the flame sensor, the flame symbol is illuminated. Switching Between Units of Measure Switching between temperature units of measure (°F/°C). Two yellow LEDs will be used to light up the current unit mode, °F or °C. To switch units of measure, simultaneously press the “Mode” button and the “Up” button. Fault Indication A

downloaded: 4   File size: 501 kb   Manafacture: American  
Category: Water Heaters
@name

Tank Water Heaters in a Circulation Loop...................................6 Additional Guidelines....................................................................6 Pump Sizing for Storage Tank Applications ...............................7 Pressure Loss Curves ..................................................................8 Domestic Hot Water - Standard Installation 1 Water Heater (WH-1)....................................................................9 2 Water Heaters (WH-2)............

downloaded: 2   File size: 655 kb   Manafacture: American  
Category: Water Heaters
@name

1. Turn OFF the gas supply. 2. Turn OFF the 120 V power supply. 3. Remove the front panel from the appliance. 4. Check the gas type using the data plate on the side of the unit. If using a spare PC board, check that the gas type switches are in the correct position (dip switch 1 of SW2: ON for natural gas, NG, and OFF for propane, LPG). See dip switch settings section below. (ON is towards the right and OFF is towards the left.) 5. Attach the pressure gauge to the burner test point, located on t

downloaded: 3   File size: 1 mb   Manafacture: American  
Category: Water Heaters
@name

ANSI Z21.10.3b-2008 ALL TECHNICAL AND WARRANTY QUESTIONS: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED. KEEP THIS MANUAL IN THE POCKET ON HEATER FOR FUTURE REFERENCE WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED. 316888-004 Rev. 00 TABLE OF CONTENTS TABLE OF CONTENTS SAFE INSTALLATION, USE AND SERVICE 3 GENERAL SAFETY 4 INTRODUCTION 6 Get To Know Your Water Heater - Gas Models. . . . . 8 Replacement Parts And Deliming Products . . . . . . . 8 INSTALLAT

downloaded: 0   File size: 1 mb   Manafacture: American  
Category: Water Heaters
@name

KEEP THIS MANUAL IN THE POCKET ON HEATER FOR FUTURE REFERENCE WHEN EVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED. PRINTED IN THE U.S.A 0510 PART NO. 318281-000 SAFE INSTALLATION, USE AND SERVICE SAFE INSTALLATION, USE AND SERVICE Your safety and the safety of others is extremely important in the installation, use, and servicing of this water heater. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potent

downloaded: 0   File size: 152 kb   Manafacture: American  
Category: Water Heaters
@name

The 50-gallon water heater delivers hot water output that rivals a 75-gallon atmospheric gas water heater. In fact, the fully condensing design is so advanced, it can deliver “endless hot water for showers”…a continuous flow of over 3 gallons per minute. * Yet it is easy to install, with height, diameter and installation requirements similar to standard power-vent units. HELICAL INTERNAL HEAT EXCHANGER • Positioned in the center of the tank, surrounded by water to virtually eliminate radiant hea

downloaded: 1   File size: 655 kb   Manafacture: American  
Category: Water Heaters
@name

• Measure resistance of valve coil. 52 Modulating Solenoid Valve Signal Abnormal • Ensure fan will turn freely. • Check wiring harness to motor for damaged and/or loose connections. • Measure resistance of motor winding. 61 Combustion Fan Failure If blank screen is present on remote control then the flow control has shorted out. Unplug flow control. If remote lights up and unit starts operating then replace flow control assembly. 65 Water Flow Servo Faulty (does not stop flow properly) • Check w

downloaded: 6   File size: 965 kb   Manafacture: American  
Category: Water Heaters





Category